Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 330 for “"external beam"”
-
Characterizing canine dose from external beam irradiation
Absorbed dose from Computed Tomography (CT) is a major concern on an individual basis as well as for the collective population due to increased frequency of and dependency on CT scans for diagnostic and therapeutic imaging. Colorado State University recently integrated a large bore multi-slice …
-
Optimization approaches for planning external beam radiotherapy
External beam radiotherapy is delivered from outside the body aimed at cancer cells to damage their DNA making them unable to divide and reproduce. The beams travel through the body and may damage nearby healthy tissues unless carefully planned. Therefore, the goal of treatment plan optimization is …
-
A Monte Carlo Investigation in External Beam Radiotherapy
Monte Carlo techniques have been shown to be the most accurate method of modelling radiation transport and dose deposition. With increasingly complex radiotherapy techniques being employed in the continuing fight against cancer, Monte Carlo techniques provide a de finitive method to assess the …
-
Cost-Effectiveness Analysis of Radical Prostatectomy, External Beam Radiotherapy and External Beam Radiotherapy with Brachytherapy Boost for Very High-Risk Prostate Cancer
… of radical prostatectomy (RP), external beam radiotherapy (EBRT) monotherapy, and EBRT+brachytherapy for men with very high-risk prostate cancer (VHRPC). Methods: Using a decision tree with embedded Markov process models, a cost-utility analysis was performed comparing the three …
-
Studies of the external beam of the McGill synchro-cyclotron.
This thesis describes the manner in which a beam of 25 x 10^6 protons/second at 90 Mev was extracted from the McGill synchrocyclotron and taken to a well-shielded position. A 1.46 gms/cm^2 uranium foil scattered the main cyclotron beam 5.5° into a magnet channel which was placed 3-4° in azimuth …
-
Modelling Tumour Control in External Beam Radiotherapy for Prostate Cancer
… changed biological modeling of tumour control in external beam radiotherapy for prostate cancer. This work ultimately demonstrates that bystander effects can modify predicted outcomes of tumour control. We have shown that bystander effects potentially improve TCP under geometric miss and that …
-
Entropic model for dose calculation in external beam radiotherapy and brachytherapy
Ce travail est dédié au développement et à la validation d'un nouvel algorithme de résolution de l’équation de Boltzmann sur une grille cartésienne pour le transport et le dépôt d'énergie de particules énergétiques et de rayons X dans les tissus humains. Ce modèle basé sur une fermeture entropique …
-
Real-Time Ultrasound Image-Guidance and Tracking in External Beam Radiotherapy
… vein branches (non-spherical structure). An external marker was attached to the surface of both phantoms and volunteers as a secondary tracked object by an infrared camera for comparison. Residual intrafractional motion of DIBH tracking target relative to beginning position in each …
-
Technological advances in external beam radiotherapy. Study of new treatment strategies.
… covers the use of advanced technologies in external beam radiotherapy (EBRT), such as proton therapy for thoracic tumors, a central issue with significant implications for radiation oncology. By combining motion management, adaptive planning, and radiobiological modeling, my Ph.D. work aims …
-
Assessing the mechanistic synergy between cancer virotherapy and external beam radiation
<p>One of the core radiobiological features determining response to fractionated treatment is repair of ionising radiation-mediated damage. Adenoviruses are shown to inhibit the DNA damage response (DDR), in particular the pathways involved in repairing double-strand DNA breaks. Combination …
-
Investigation of Advanced Dose Verification Techniques for External Beam Radiation Treatment
… electrons generated by the TRD in a 6 MV photon beam were investigated using Monte Carlo (MC) simulation. This study demonstrates that modification of the contaminant electron model in the treatment planning system is required for accurate patient dose calculation in buildup regions when using …
-
Optimising External Beam Radiotherapy for Prostate Cancer. Advances in Treatment Planning
… to regional lymph nodes (Papers I-II). Cone-beam computed tomography (CBCT) imaging data from the PROPER 1 study was used to analyse estimated delivered radiation dose distributions, comparing them with initial plans (Paper III) and evaluating potential dose-volume associations with side …
-
Optical fibre dosimetry in external beam radiotherapy: Measurements and Monte Carlo simulation
… the inorganic scintillation detector system for external beam radiotherapy was evaluated. Results obtained demonstrated promising characteristics when used in external beam radiation therapy settings. However, the system overestimated the dose when measuring percentage depth dose and lateral dose …
-
In Vivo Dosimetry Using Plastic Scintillation Detectors For External Beam Radiation Therapy
… PSDs have not been used for in vivo dosimetry of external beam radiation therapy to date. The overall purpose of this work is to apply PSDs to in vivo dosimetry of external beam radiation therapy, and demonstrate the utility and practicality of performing in vivo dosimetry with PSDs. Three avenues …
-
Towards personalized PTV margins for external beam radiation therapy of the prostate
External Beam Radiation Therapy (EBRT) is a common treatment option for patients with prostate cancer. When treating the prostate with EBRT, a geometric volume (PTV margin) is added around the prostate to account for uncertainties in treatment planning and delivery. Current methods for estimating …
-
Convex and Robust Optimization Methods for Modality Selection in External Beam Radiotherapy
The goal in external beam radiotherapy (EBRT) for cancer is to maximize damage to the tumor while limiting toxic effects of radiation dose on the organs-at-risk (OAR). EBRT can be delivered via different modalities such as photons, protons, and neutrons. The choice of an optimal modality depends on …
-
External beam prostate radiotherapy: anorectal toxicity and the influence of endorectal balloons
Radboud Universiteit Nijmegen, 14 juni 2012
-
Feasibility Study of Intensity Modulation for Low Dose Rate External Beam Radiation Therapy
… radiobiological advantages for normal tissue. External irradiation techniques have been developed which use static blocked fields to irradiate a target which give a uniform dose rate over the area of the field but are unable to preferentially reduce dose to critical structures near the target. …
-
Combined Nd YAG laser and external beam radiotherapy for palliation in gastrointestinal cancer
… cancers but deep tumour is inaccessible. External beam radiotherapy alone can be effectively used to treat all local tumour but its effect is delayed and effective recanalisation is often not achieved. There is very little data on how these treatments can best be combined to achieve the …
-
Systematic dose-effect studies of radionuclide and external beam therapies for cancer treatment
<b>Introduction</b>: Contrary to External Beam Radiation Therapy (EBRT), the radiobiological effects in cells and tissues once exposed to Auger Electron (AE)-emitters technetium-99m (99mTc) and iodine-123 (123I) and Beta (β)─ particle emitter rhenium-188 (188Re) and their relationship with the …
Page 1 of 17