Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 17 of 17 for “"external prestressing"”.
-
Strengthening of RC Beams and Frames by External Prestressing
The use of external post-tensioning in strengthening continuous beams in reinforced concrete frames was investigated. First, a direct method to determine the required external tendons and to evaluate the load-carrying capacity of strengthened beams was proposed. The method was verified with test …
-
Seismic retrofitting of concrete bridge columns by external prestressing.
… retrofitting technique consists of wrapping and prestressing high strength steel 7-wire strands around the test columns in order to increase their ductility. The specimen's tested were based on pre-1971 design, and hence had larger transverse reinforcement spacing than the present practice. This …
-
Seismic retrofit of concrete columns with splice deficiencies by external prestressing.
… of Ottawa. The new procedure consists of external prestressing existing columns with seven wire strands. External prestressing overcomes diagonal tension caused by shear, confines compression concrete, and may improve the behaviour of spliced reinforcement under reversed cyclic loading. …
-
Enhancing Shear Strength of Post-tensioned Precast Concrete Bridge Girders Using External Prestressing: Experimental and Analytical Investigation
… force resisted by concrete. The effectiveness of external post-tensioning as an alternative to conventional internal post-tensioning is also investigated. An external post-tensioning design was proposed for an actual internally post-tensioned bridge girder built in Calgary. The effective web …
-
Strengthening prestressed beams using parafil ropes as external tendons
… several methods can be used, one of them is the external prestressing. Also, to avoid corrosion problem that faced this type of strengthening, Fibre Reinforced Plastics (FRP) can be used instead of steel tendons. Within the different types of FRP, Parafil rope was established to be well suited …
-
Seismic Retrofit of Concrete Columns by Transverse Prestressing
… existing columns; or by applying transverse prestressing to columns (RetroBelt System). The research project presented in this thesis involves a seismic retrofit methodology for seismically deficient building and bridge columns, utilizing the use of high-strength packaging straps as external …
-
Multi-scale investigation on durability and long-term behaviour of concrete elements strengthened with CFRP laminates according to the EBR and NSM techniques
… mainly by using the passive techniques such as Externally Bonded Reinforcement (EBR) and Near Surface Mounted (NSM). Furthermore, EBR technique can be improved with the use of active external prestressing by means of the Mechanical Anchorage (MA) and Gradient Anchorage (GA). Typically, …
-
Seismic evaluation and retrofit of existing reinforced concrete bridge columns.
… This can be achieved in old columns through external retrofitting. Many reinforced concrete bridge columns in California were already retrofitted with steel jackets to enhance flexural ductility and shear resistance. Although this retrofitting technique is highly effective, it is also time …
-
Monotonic and Fatigue Performance of RC Beams Strengthened with Externally Post-Tensioned CFRP Tendons
External post-tensioning is an attractive technique for strengthening reinforced concrete structures because of its ability to actively control stresses and deflections, speed of installation, minimum interruption for the existing structure, and ease of inspection under service conditions. However, …
-
Hardening of Reinforced Concrete Columns Against Blast Loading by Prestressing and ECC Jacketing
… ground-floor columns, which are susceptible to external surface blasts typically triggered by vehicular or hand-carried bombs. The proposed hardening technique primarily consists of lateral support(s) provided by external prestressing strands against blast loads, which is at the forefront of …
-
Modelagem tridimensional de estruturas compostas por aduelas pré-moldadas de concreto com protensão externa, através do método dos elementos finitos
O uso de aduelas pré-moldadas de concreto se transformou na técnica preponderante na construção de pontes com vãos médios a longos. No entanto, fatores econômicos têm continuamente exigido refinamentos nessas práticas de construção para o aumento da produtividade e redução do tempo de construção. …
-
Προτάσεις διαμόρφωσης και εφαρμογής συστημάτων ελέγχου των παραμορφώσεων σε φορείς μεγάλου ανοίγματος με την χρήση καλωδίων
… on cable supported beam nets with additional prestressing control of the support cables such as to optimize the structural behavior of the system: the passive control design problem leads to an optimal control problem for structures governed by variational inequalities. The optimal shape of a …
-
Análise de pontes em estruturas mistas de aço-concreto de seção caixão com protensão externa
Estruturas Mistas de Aço-Concreto têm sido usadas extensivamente na construção de pontes e viadutos urbanos, especialmente a partir da segunda metade do século XX. A popularidade desse tipo de solução, com seções caixão, cresceu devido a sua alta capacidade à flexão, rigidez à torção e uma seção …
-
Posouzení aktuálního stavu a statické zajištění stávající prefabrikované konstrukce
Tato diplomová práce se zabývá přepočtem stávajícího předpjatého střešního vazníku. Cílem bylo zjistit důvod vzniku trhlin na vazníku v krátké době po zbudování konstrukce haly a návrh jeho zesílení.
-
Návrh zesílení stropní konstrukce ve Zlíně
Bakalářská práce se zabývá zesílením stropní konstrukce vícepodlažní budovy ve Zlíně. V první části práce je řešena stávající únosnost konstrukce. Cílem práce je návrh zesílení stropní konstrukce a ověření na mezní stavy únosnosti a použitelnosti. Průvlaky jsou zesíleny volnými předpínacími lany.
-
Zesílení předpjatého mostu z roku 1960
Cílem bakalářské práce je navrhnout a posoudit zesílení původního předpjatého mostu „Gagarin“ z roku 1960, který převádí jednokolejnou trať Správy železnic v km 5,872 na úseku Český Těšín – Ostrava-Kunčice. Zesílení je navrženo z důvodu opotřebení stávající konstrukce, degradace betonových částí a …
-
Rekonstrukce průmyslové budovy
Diplomová práce se zabývá posouzením stávajících železobetonových předpjatých sedlových střešních vazníků proměnného I-průřezu v objektech D_06, D_07 a D_09 areálu DELIMAX Hodonín, původně navržených v roce 1979, a návrhem nového vazníku jako náhrady vybraných prvků. V práci je popsána geometrie …