Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 54 for “"faraday cup"”.
-
The Study of Reactor Wall Fouling in Gas-solid Fluidized Beds Caused by Electrostatic Charge Generation
… bed electrification and reactor wall fouling. A Faraday cup replaced the windbox of the fluidized bed while another cup was placed at the top of the column. The distributor plate was uniquely designed for the systematic removal of bed particles and those adhered to the column wall for their …
-
Design of a Triboelectric Charge Measurement System
… Methods for collecting this charge are a Faraday cup, on-line current measurement, Electric Low-Pressure Impactor (ELPI), and Electronic Single Particle Relaxation Time (ESPART). Research articles have predominately been completed with measurement research using the Faraday cup. Factors …
-
Apparatus and Instrumentation Design for Investigation of Surface Impact Effects on Superconductivity
… explanation of beam characterization using the Faraday cup and faceplate is also provided in this chapter. Chapter 3 shows simulated and calculated results for the setup. Examples are given of data using the niobium experiment that is described in chapter 1. An introduction to a new plotting …
-
Thermal in situ TEM experiment on nanoscale indium islands
… calibrated as part of this work. A custom made Faraday cup is produced on a gold tip using a focused ion beam (FIB). The Faraday cup is mounted in a Nanofactory holder and the beam current is measured with a picoammeter. The calibrated conversion coefficient for the beam current is then …
-
Experimental investigations of pseudospark discharge and pseudospark produced intense electron beams
… performance as a switching device. Paper 2 "Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization" presents a specifically designed Faraday cup diagnostic with fast response time of 8.6 ns that is used to determine the time-resolved electron …
-
Formation and extraction of a dense plasma jet from a helicon-plasma-injected inertial electrostatic confinement device
… in the jet was measured by a combination of a Faraday cup and a gridded energy analyzer (GEA). The Faraday cup also included a temperature sensor for collection of thermal power measurements used to compute the efficiency of the IEC device in coupling power into the jet. The GEA allowed for …
-
A study of beam diagnostic probes for the TRIUMF accelerator.
… to be the most accurate beam energy monitor. A Faraday cup incorporated as part of one of the Proton Area beam dumps is considered the best absolute monitor for calibrating other intensity monitors.
-
Ion source development
… up to mass three ions, focussing them into a Faraday cup. The source delivers a beam containing 45% protons. A total current of 800 microamperes of positive ions has been measured.
-
Beam current monitoring and radiachromic film dosimetry at the NPS Linac.
… defined as the ratio of SEM current of Faraday cup current, was found to increase with increasing beam energy, increase with the introduction of targets into the beam, and vary erratically with SEM foil surface conditions. No dependence on beam current was observed. The spatial variation …
-
Computational studies of laser-matter interactions
… results obtained from ion calorimeter and Faraday cup measurements. The calculated and measured intensity scalings were found to be in good agreement. The stronger wavelength scaling observed in the experimental results is explained by considering the effects of X-ray radiation from the hot …
-
Characterization and First Results of an Inverse Photoemission Spectrometer
… total current delivered by the beam using just a Faraday cup. Measurements of the beam’s profile are presented and are used to calculate the parallel momentum resolution of the beam. Equally important is the characterization of our photon detectors, which we show are operating in the proportional …
-
Hydrodynamics of laser-driven ablation in planar targets
… results obtained from ion calorimeter and Faraday cup measurements. Secondly, target motion was studied using these diagnostics and the results were interpreted by viewing the target as a compressible fluid (shock compressed) which subsequently rarefies. Target rarefaction was also directly …
-
Control and characterization of a cyclotron proton beam
… directions; with the beam in the z-direction. A Faraday cup was used as a diagnostic to monitor and characterize the beam after deflection. The system was designed by using magnetic circuit theory and fundamental electromagnetic theory. A software package called finite element method magnetic …
-
The excitation and ionization of fast He+ ions passing through a thin carbon foil
… allowed the use of high beam currents and simple Faraday cup detectors. The results are in good agreement with that of Armstrong, et. al., who used single particle detectors and low beam currents. In the second part of this thesis, the charge state fractions were used to normalize the data of …
-
Development of a ferroelectric plasma source through material degradation studies and characterization of volume and surface discharges
… 100000 pulses. Emission is characterized with a Faraday cup, a fast photodiode, an optical emission spectrometer (OES), a residual gas analyzer (RGA), and a quartz crystal microbalance (QCM) that all monitor output during the emission process. The Faraday cup serves as an excellent detector of …
-
Mass spectrometry of a fast plasma jet
… plasma drift velocity was measured by the use of Faraday cup probes. A small portion of the plasma is analyzed by accelerating the ions with a pulsed electric field into a drift section with an electron multiplier at its end. The time delay between the creation of the plasma and the accelerating …
-
Crossed Field Trochoidal Trajectory Devices for Investigating the Reflection of Slow Electrons from Metallic Surfaces
… to the electrodes. Each device utilized a Faraday cup to collect the electrons after the application of an external uniform magnetic field which bent the originally straight electron beam into a trochoidal path.
-
Characterization of a piezoelectric transformer plasma source
… monitors, emission current measurements with a Faraday cup and retarding potential analyzer, and imaging with an optical spectrometer and an ICCD camera.
-
Influence of source parameters on the properties of a plasma jet
… to diagnose the temperature of the plasma. Faraday cup probes and a time of flight mass spectrometer are also used as diagnostics to find the plasma composition and velocity of the various species. The data acquisition is automated by the use of an HP Vectra computer and three HP digital …
Page 1 of 3