Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 60 for “"fast scanning"”.

  1. Data acquisition and processing for a fast scanning spectroradiometer

    … A 1/2-meter grating spectrograph was rendered a fast scanning device by using a wavelength scanning mirror behind the entrance slit, along with a customized detector assembly on the exit focal plane. The detector assembly consists of eight Indium Antimonide detectors, with each detector having a …

    ut-knoxville Repository record for Data acquisition and processing for a fast scanning spectroradiometer (opens in a new tab)

  2. Design of Fast Scanning Controller for Atomic Force Microscope

    The main concern of this thesis is to improve the imaging performance of an Atomic Force Microscope (AFM). According to the purpose of this work, an internal reference model-based optimal Linear Quadratic Gaussian (LQG) controller is designed for the lateral positioning of a Piezoelectric Tube …

    unsw Repository record for Design of Fast Scanning Controller for Atomic Force Microscope (opens in a new tab)

  3. Application of field programmable analog arrays (FPAAs) to fast scanning probe microscopy

    … and ease of implementation in developing fast and robust controllers for an Atomic Force Microscope (AFM) unit. Atomic Force Microscopes (AFMs) are getting faster. However, video-rate imaging still remains a big challenge to the AFM community. Therefore AFMs are required to have very fast …

    uiuc Repository record for Application of field programmable analog arrays (FPAAs) to fast scanning probe microscopy (opens in a new tab)

  4. MEMS enabled miniaturisation of photoacoustic imaging and sensing systems

    … consisting of MEMS based excitation - using a fast-scanning micro-mirror for Q-switching - and detection schemes is built and used to image synthetic targets and phantoms.Furthermore, a simulation model of the system is developed to evaluate influences of the miniaturised elements on the …

    strathclyde Repository record for MEMS enabled miniaturisation of photoacoustic imaging and sensing systems (opens in a new tab)

  5. A Close Look at the Phase Behavior of Polymer Semiconductors Using Fast Calorimetry

    … motivation, introducing the implementation of fast scanning calorimetry and concluding with an outline of the thesis scope. Chapter 2 builds on this foundation by detailing the characterization methodologies and relevant material information. In Chapter 3, we apply fast scanning calorimetry to …

    gatech Repository record for A Close Look at the Phase Behavior of Polymer Semiconductors Using Fast Calorimetry (opens in a new tab)

  6. Glass transition temperature and reaction kinetics of cyanurates in bulk and under confinement and signatures of structural recovery of polystyrene

    … and thin film confinement using conventional and fast scanning calorimetry, respectively. A Tg depression is observed under both confinement geometries and the volume to surface area ratio of the confining mediums is used to collapse the Tg depressions onto a single curve. The relationship between …

    ttu Repository record for Glass transition temperature and reaction kinetics of cyanurates in bulk and under confinement and signatures of structural recovery of polystyrene (opens in a new tab)

  7. High-Speed Reconstruction of Low-Dose CT Using Iterative Techniques for Image-Guided Interventions

    … patient trauma. Because of features such as fast scanning, high resolution, three-dimensional view and ease of operation, Computed-Tomography(CT) is increasingly the choice for IGIs. The risk of radiation exposure, however, limits its current and future use. We perform ultra low-dose scanning …

    maryland Repository record for High-Speed Reconstruction of Low-Dose CT Using Iterative Techniques for Image-Guided Interventions (opens in a new tab)

  8. DEGENERATE SECOND ORDER NONLINEAR OPTICAL SPECTROSCOPY OF CHIRAL WEYL SEMIMETALS

    … grating. In our work on SHG, we describe a fast-reflective optic-based rotational anisotropy nonlinear harmonic generation spectrometer built upon synchronization of stepper motors and a voice-coil fast turning motor with data recorded by a data acquisition card. This device enables fast …

    temple Repository record for DEGENERATE SECOND ORDER NONLINEAR OPTICAL SPECTROSCOPY OF CHIRAL WEYL SEMIMETALS (opens in a new tab)

  9. Optically-Transparent Focused Transducers on Polymer Substrates for Photoacoustic Microscopy

    … are especially useful for the development of fast scanning transducers for enabling miniaturized and high-speed PAM systems.

    tamu Repository record for Optically-Transparent Focused Transducers on Polymer Substrates for Photoacoustic Microscopy (opens in a new tab)

  10. Structure-Property Interrelations of Polymers for Photonics and Electronics

    … of semiconducting polymers are established using fast scanning calorimetry. The field of polymer-based electronics has witnessed major developments in the past few years that have led to systems of vastly improved charge transport- and energy-harvesting properties. This progress can be …

    gatech Repository record for Structure-Property Interrelations of Polymers for Photonics and Electronics (opens in a new tab)

  11. Semicrystalline polymers in material extrusion additive manufacturing

    … and deformation characteristics of MEX parts. Fast scanning calorimetry showed that the cooling rates experienced during MEX hindered the crystallization of PPS. In addition, a process optimization of material dependent thermal history parameters reduced the disparities between bulk and MEX …

    gatech Repository record for Semicrystalline polymers in material extrusion additive manufacturing (opens in a new tab)

  12. Improvement of Synchrotron Radiation Propagation-based Imaging Computed Tomography for Tissue-scaffold Visualization

    … resolution, sufficient contrast, and relatively fast scanning. Notably, SR-PBI-CT is currently facing some challenges specific to scaffold visualization applications. Among these, two key issues urgently need to be resolved. The first issue is the ring artifacts in SR-PBI-CT images, which …

    sask Repository record for Improvement of Synchrotron Radiation Propagation-based Imaging Computed Tomography for Tissue-scaffold Visualization (opens in a new tab)

  13. Bioreneweable polymer nanocomposites: A study of the design space available for cellulose nanocrystal/poly(3-hydroxybutyrate) nanocomposites

    … using DSC, hot stage microscopy, and a novel fast scanning chip calorimeter, the Flash DSC. Results show that the addition of water during SC processing significantly reduced the rate of crystallization at both isothermal and nonisothermal conditions. This reduction in crystallization rate was …

    gatech Repository record for Bioreneweable polymer nanocomposites: A study of the design space available for cellulose nanocrystal/poly(3-hydroxybutyrate) nanocomposites (opens in a new tab)

  14. Modeling of PEEK crystallization kinetics under transient thermal conditions

    … are inaccessible by conventional differential scanning calorimetry (DSC). Existing crystallization models are typically calibrated on narrow isothermal ranges and slow constant-rate experiments using conventional DSC. As a result, they break down under the fast, transient cooling profiles …

    ubc Repository record for Modeling of PEEK crystallization kinetics under transient thermal conditions (opens in a new tab) Download PDF for Modeling of PEEK crystallization kinetics under transient thermal conditions (opens in a new tab)

  15. Characterisation of crystallisation and melting in thermoplastic polymers using chip calorimetry

    Fast scanning chip-calorimetry was used to explore the crystallisation and melting of three semi-crystalline polymers. The heating and cooling rates required to prevent crystallisation on cooling (from above Tm) and on re-heating (from below T\(_g\)) were determined as: 3,000 and 8,000˚C/s …

    birmingham Download PDF for Characterisation of crystallisation and melting in thermoplastic polymers using chip calorimetry (opens in a new tab)

  16. Towards Developing a Scanning Position Sensitive Detector (PSD) Microscopy: PSD Measurement Enhancement, Adaptive Local Scanning and Implementation

    … the PSD. That is a new microscopy system called scanning PSDmicroscopy. The working mechanism is about putting an object on the surface ofthe PSD and fast scanning its area with a laser beam. To achieve a high degree ofaccuracy and precision, a reliable framework was designed using the PSD. In …

    unr Repository record for Towards Developing a Scanning Position Sensitive Detector (PSD) Microscopy: PSD Measurement Enhancement, Adaptive Local Scanning and Implementation (opens in a new tab)

  17. Multi-Species Measurements at High Temperatures Using Advanced Mid-Infrared Laser Schemes

    … in fuel-rich n-heptane combustion; a fast-scanning broadly tunable acousto-optically modulated external cavity quantum cascade laser scheme for simultaneous measurements of temperature and carbon monoxide concentration; and a broadband absorption diagnostic based on a MIR frequency …

    ucf Repository record for Multi-Species Measurements at High Temperatures Using Advanced Mid-Infrared Laser Schemes (opens in a new tab)

Page 1 of 3