Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 45 for “"fault resistance"”.
-
The Protection of Transmission Lines Connected to DFIG-Based WTGs
… of the DFIGs, and the impact of the fault resistance on the calculated impedance. The protection challenge associated with the frequency deviation caused by the short-circuit characteristics of DFIG is further discussed in detail, and a modified permissive underreaching transfer trip …
-
FAULT IDENTIFICATION ON ELECTRICAL TRANSMISSION LINES USING ARTIFICIAL NEURAL NETWORKS
… cause abnormal conditions known as electrical faults. Electrical faults, when isolated, can cripple the transmission system as power flows are directed around these faults therefore leading to other numerous potential issues such as thermal and voltage violations, customer interruptions, or …
-
Computer relaying for EHV/UHV transmission lines
… compensation system will be put into use. Once a fault occurs on such a system, a delay in clearing the fault is usually not permissive. This requires a new generation of relays which have high security and dependability and high operating speed. With the advent of high speed microprocessor and …
-
ESTIMATING THE LOCATION OF A TRANSMISSION LINE SHUNT FAULT FROM DIGITAL IMPEDANCE RELAY MEASUREMENTS
… for transmission line protection identify the faulted zone but do not provide any information concerning the exact location of the fault. Fault locators, that estimate the distance to a fault point on a transmission line, conventionally measure the apparent impedance to the fault from a line …
-
Smart Meter Data-Driven Fault Location Algorithm in Distribution Systems
Whenever there is a fault in the power system, the reliability of the network is compromised. This is why fault should be located as fast as possible and the system must be restored to the pre-fault values. Fault location and restoration is one of the functions of Distribution Automation (DA). In …
-
Clearing of single phase to ground faults
… selective clearing of single phase to ground faults. Actual fault currents are sometimes lower than calculated, and directional relays sometimes determine the wrong direction. Considering lower than calculated fault currents, the paper proposes several adaptions to present fault calculations …
-
NEW FAULT LOCATION ALGORITHMS FOR HIGH VOLTAGE TRANSMISSION LINES
The detailed developments of fault location algorithms for single-circuit and two individually transposed parallel transmission lines have been presented in this thesis. These algorithms are based on the widely used and time tested symmetrical components theory. Digital simulations and sensitivity …
-
Treanmission Line Fault Location using Interoperability and Integration of Data and Model
… proposes selective scheme of transmission line fault location by choosing between two different types of fault location algorithms depending on the availability of measurements. The first type is an accurate method to detect, classify and locate transmission line faults using synchronous samples …
-
Localização de faltas em linhas de transmissão usando morfologia matemática
This work an algorithm for fault location is proposed. It contains the following functions: fault detection, fault classification and fault location. Mathematical Morphology is used to process currents obtained in the monitored terminals. Unlike Fourier and Wavelet transforms that are usually …
-
Βελτιστοποίηση ρυθμίσεων στοιχείων υπερέντασης σε προσαρμοστικά ή μη συστήματα προστασίας σύγχρονων δικτύων διανομής και συστημάτων μεταφοράς
… systems are described. Moreover, the theory of fault analysis is explained concisely, providing the essential background for the comprehension of short-circuit current nature and protection techniques. Great emphasis is laid on the special case of double-phase-to-ground faults in effectively …
-
Fault Impedance Characterization for High Voltage Applications in Power Systems
… effects of the characteristics of high impedance faults on the performance of line distance protection. Two typical models are implemented.The verification of those models is done both with conventional sources and with a renewable source of Type-3 and Type-4 wind turbines. The results are …
-
Wavelet-based analysis and detection of fault-induced transients in HVDC systems
… analysis of the traveling waves induced by faults on direct current (DC) transmission lines of HVDC systems is presented for detecting the wavefront arrival times using the boundary wavelet coefficients from real-time boundary stationary wavelet transform (RT-BSWT). This qualitative analysis …
-
A current-only faulted section identification scheme for power system protection
This thesis presents a faulted section identification scheme designed for modern distribution networks, which is applicable to power system protection and/ or to the emergent "fault location, isolation, and service restoration" (FLISR) set of functions (often also termed "distribution automation" …
-
Automated model-based transmission line fault location method using reduced equivalent circuit
… and are prone to a variety of short-circuit faults. Transmission line faults must be accurately identified and cleared so as to restore the faulted line back to normal operation in the shortest amount of time possible. Common fault locating practices used by utilities involve multiple manual …
-
Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers
… as those experienced during a large external fault, also contribute to weakening a transformer's insulation. Once these stresses have weakened the insulation to the point of breakdown, a fault may occur between windings of the transformer. These faults, known as turn-to-turn faults, are …
-
A TECHNIQUE FOR ESTIMATING TRANSMISSION LINE FAULT LOCATIONS FROM DIGITAL IMPEDANCE RELAY MEASUREMENTS
… estimating locations of transmission line shunt faults has been to measure the apparent impedance to the fault from a line terminal and convert the impedance to line length. One factor that adversely affects fault location estimates is the fault resistance that appears to the relay to be an …
-
PMU-Driven Fault Location in Distribution Systems with DERs: Impedance-Based and Multi-Agent System Strategies
… by feeder heterogeneity, low reactance-to-resistance ratios, and unbalanced loads. These factors complicate system awareness and observability, making fault detection and isolation essential for rapid reconfiguration and service restoration. The growing demand for power quality, security, …
-
Voltage-based backup protection and protection performance analysis using wide-area PMU data
… The ability to rapidly identify the presence of faults, their locations and the presence of protection/circuit breaker failures, solely from voltage measurements, is the overarching contribution from this work. The scheme can operate in addition to existing backup schemes to provide a further, or …
-
Adaptive digital distance protection
… relay to provide ultra-high-speed operation for faulted waveforms which do not require extensive filtering, yet provides discrimination and very-high-speed operation for more distorted waveforms. To improve the reach point accuracy and fault resistance coverage for high resistance earth faults, …
-
Research into a new fault generated noise distribution system fault locator
… associated with detection and clearing of faults on overhead distribution systems, particularly in interconnected networks, are still of great concern. Most utilities employ reclosing relays with circuit breakers to handle transient faults. Permanent faults, however, require a location of …
Page 1 of 3