Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"febio"”.

  1. Simulating Size Selectivity of Albumin through the Kidney Filtration Barrier using FEBio

    … construct the model. We use open-source software FEBio (Finite Elements for Biomechanics) to simulate fluid and solute transport in different layers of the GFB. From the ultrastructural model of the GFB, 3D fluid domain volumes were constructed for FEBio simulations. Paired with Coreform Cubit …

    buffalo Repository record for Simulating Size Selectivity of Albumin through the Kidney Filtration Barrier using FEBio (opens in a new tab)

  2. Strain Response in Osteocyte Lacuna Due to Mechanical Loading - a Parametric Finite Element Study Using FEBio

    … study, a finite element model was created using FEBio at the microscale level and osteocyte lacunar and perilacunar responses were calculated based on three studies: 1) variation in lacunar position, 2) variation in lacunar orientation and 3) variation in lacunar size. A parametric study was …

    umkc Repository record for Strain Response in Osteocyte Lacuna Due to Mechanical Loading - a Parametric Finite Element Study Using FEBio (opens in a new tab)

  3. Toward interoperability between FEM systems: A domain-aware framework for translating and benchmarking FEBio models in PolyFEM

    … that problem through a case study of translating FEBio models into PolyFEM-compatible representations. The thesis presents a modular Python framework for parsing, translating, and bench- marking FEBio models in PolyFEM. The framework includes a FEBio parser, an intermediate repre- sentation, a …

    uvic Repository record for Toward interoperability between FEM systems: A domain-aware framework for translating and benchmarking FEBio models in PolyFEM (opens in a new tab)

  4. Iron bioavailability in low phytate pea

    … and low phytate varieties. Iron bioavailability (FEBIO) of the two low-phytate lines was 1.4 to 1.9 times higher than that of the three normal phytate varieties, and growing environment also had a significant effect on FEBIO. Peas with pigmented seed coats contained 7 times lower FEBIO than peas …

    sask Repository record for Iron bioavailability in low phytate pea (opens in a new tab)

  5. Bridging the Gap Between Biomechanics and Modern Computer Architecture: Analyzing Bottlenecks in a Human Eye Simulation

    … biological systems under various conditions. FEBio, an open-source FEA software designed for biomechanic and biomedical research, is widely used for such applications. However, its computational performance across various workloads remains an important consideration for researchers seeking …

    maryland Repository record for Bridging the Gap Between Biomechanics and Modern Computer Architecture: Analyzing Bottlenecks in a Human Eye Simulation (opens in a new tab)

  6. Biomechanical biomarkers of cancer

    … using the newly develop finite element programme FEBio. A previous study by Busby et al. suggested that confined compression, along with biphasic theory, was a suitable technique for determining the mechanical properties of collagen hydrogels. Therefore, FEBio was used to create both force and …

    strathclyde Repository record for Biomechanical biomarkers of cancer (opens in a new tab)

  7. Tibial cartilage stress analysis in osteoarthritis development : a comparison of traumatic injury and degenerative causes using finite element analysis

    … úr segulómun. Líkönin voru greind með forritinu FEBio en niðurstöður þess voru hærri spennugildi í áverka- og slitgigtar hópunum samanborið við viðmið. Þær niðurstöður gefa vísbendingu um þætti sem leiða til slitgigtar og gætu leitt til nýrra forvarna gegn sjúkdóminum.

    reykjavik Repository record for Tibial cartilage stress analysis in osteoarthritis development : a comparison of traumatic injury and degenerative causes using finite element analysis (opens in a new tab)

  8. The Effect of Bone and Ligament Morphology of Ankle Joint Loading in the Neutral Position

    … talus). A finite element model was developed in FEBio (FEBio, Salt Lake City, UT) from the CT data obtained from one cadaver. The model included bones, cartilage, and ligaments. Ligaments were modeled as tension-only linear springs, and applied for more than one spring for each of 13 major …

    odu Repository record for The Effect of Bone and Ligament Morphology of Ankle Joint Loading in the Neutral Position (opens in a new tab)

  9. Příprava a testování lehčených kompozitních materiálů

    … Jako vyhodnocovací software byl použit program FEBIO Studio. Teoretická část je rozložena do čtyřech oblastí – auxetické materiály, polymerní materiály s tvarovou pamětí, auxetické materiály s funkcí samouspořádání a teplotní roztažnost auxetických materiálů. U každé části jsou stručně shrnuty …

    brno-tech Repository record for Příprava a testování lehčených kompozitních materiálů (opens in a new tab)

  10. Influence of Perivascular Adipose Tissue on Central Arterial Mechanics and Hemodynamics: A Parametric Fluid Structure Interaction Analysis

    … using the open-source finite element software, FEBio. For FSI analysis, normal, aged, and fibulin-5 deficient (early aging symptoms) suprarenal abdominal aorta (SAA), infrarenal abdominal aorta (IAA), and common carotid artery (CCA) of mice are used as model vessels. Different in-vivo …

    ecu Repository record for Influence of Perivascular Adipose Tissue on Central Arterial Mechanics and Hemodynamics: A Parametric Fluid Structure Interaction Analysis (opens in a new tab)

  11. Finite Element Analysis of the Effect of Low-Speed Rear End Collisions on the Medial Meniscus

    … torques imposed on the knee using the software FEBio. Compressive loading, knee flexion, axial torque, and varus torque were applied to the knee through the femur, and the stress and strain within the medial meniscus were determined. It was found that increased knee flexion along with …

    uconn-diss Repository record for Finite Element Analysis of the Effect of Low-Speed Rear End Collisions on the Medial Meniscus (opens in a new tab)

  12. Evaluation of the relationship between lacunar wall strain and osteocyte β-catenin signaling pathway activation using finite element methods and confocal fluorescence imaging.

    … network. The finite element analysis software FEBio was used to perform strain analysis on the models and predict bone strain in the bone matrix of the samples. The levels of Wnt/β-catenin signaling in the loaded bone were significantly higher than in the non-loaded bone. In the non-loaded …

    umkc Repository record for Evaluation of the relationship between lacunar wall strain and osteocyte β-catenin signaling pathway activation using finite element methods and confocal fluorescence imaging. (opens in a new tab)

  13. COMPUTATIONAL ULTRASOUND ELASTOGRAPHY: A FEASIBILITY STUDY

    … software packages including Field II, VTK, FEBio and Tetgen. The proposed virtual simulation platform can be used to simulate SE and acoustic radiation force based SWE simulations, including pSWE, SSI and ARFI. To demonstrate its usefulness, in this thesis, examples for breast cancer …

    mtu Repository record for COMPUTATIONAL ULTRASOUND ELASTOGRAPHY: A FEASIBILITY STUDY (opens in a new tab)

  14. Computational methods for the analysis of cell migration and motility

    … and structural optimization models in ANSYS and FEBio, which uses the finite element method, so that a reasonable range of these stresses during CCM can be provided. To further study the individual mechanics of cell migration, the proposed hybrid model is extended to a fully dynamic model which …

    colostate Repository record for Computational methods for the analysis of cell migration and motility (opens in a new tab)

  15. Computational and Experimental Comparison on the Effects of Flow-Induced Compression on the Permeability of Collagen Gels

    … biphasic compression of the collagen gels using FEBio. A neo-Hookean material was used to model the solid matrix and Young’s modulus was changed to match the degree of compression. The vertical apparatus found a higher permeability compared to the horizontal apparatus. The vertical apparatus …

    umn Repository record for Computational and Experimental Comparison on the Effects of Flow-Induced Compression on the Permeability of Collagen Gels (opens in a new tab)

  16. Patient Specific Tissue Emulating Phantoms for Image-guided Intervention Applications

    … boundary conditions, were imported into the FEBio, an open-source modeling software, and used to predict the displacement field that best maps the pre-operative liver phantom model extracted from the corresponding CT image pre-deformation to match the deformed, intra-operative liver model. We …

    rit Repository record for Patient Specific Tissue Emulating Phantoms for Image-guided Intervention Applications (opens in a new tab)

  17. Breast Cancer Detection Using Microwave Low-Frequency Metasurface-Based Techniques

    … biomechanics finite element simulation software (FEBio) to simulate the physical compression of anatomically realistic breast phantoms. The phantoms are 3D anatomically realistic and made up of MRI images. The compressed breast models derived from this part of this study will create a realistic …

    waterloo Repository record for Breast Cancer Detection Using Microwave Low-Frequency Metasurface-Based Techniques (opens in a new tab)

  18. A synergistic approach to transtibial socket interface mechanics : experiments and modeling

    … were modeled with Finite Element Methods in FEBio. The gel liner to skin interface was modeled for two situations 1) gel liner slips on the skin or 2) does not slip relative to the skin. Kinematic and kinetic conditions obtained in earlier objective served as boundary conditions. The purpose …

    msu Repository record for A synergistic approach to transtibial socket interface mechanics : experiments and modeling (opens in a new tab)

  19. Optimization of specimen geometries for mechanical testing

    Mechanical tests have been used in industry and academia for the characterization of ceramics, metals, polymers, and biological tissues. While standard testing protocols have been established for manufacturable materials, only adaptations of these procedures exists for biologics. Simulation studies …

    umn Repository record for Optimization of specimen geometries for mechanical testing (opens in a new tab)

Page 1 of 2