Computer-aided design of femoral stem prostheses
In the design of femoral stem prostheses, both biologic factors and prosthetic design features influence the long-term performance of the implant. The analysis of all these influences is difficult, if not impossible, at the present time. This research presents a computational approach, using …
-
Accounting for parameter uncertainties in the prediction of porous femoral stem reliability
… hip replacement surgery makes the reliability of femoral stems very important. Revision surgery due to aseptic loosening is one the most common reason for early failure. Aseptic loosening is reported to occur mainly due to stress shielding. Revision surgery can greatly hamper the standard and …
-
Finite element modeling of a femoral stem in a total hip prosthesis
… was produced to study of effects of stress on a femoral stem in a total hip prosthesis. Using the ANSYS General Purpose Finite Element Computer Program, a reproduction of the system was constructed for the loads acting on the hip joint at intervals of a walking cycle. With isotropic properties …
-
A Virtual Method for Establishing Femoral Stem Position in Total Hip Arthroplasty
… joint. Despite the success of these procedures, femoral stem misalignment remains an area that influences THA success. The relationship between the femoral stem geometry and implanted femoral stem size and orientation is underreported due to limitations in the collection of radiographic data used …
-
Revision Total Hip Femoral Stem Micromotion and Statistical Shape Modeling of the Knee
… to compare the amount of micromotion seen in the femoral stem in a revision total hip arthroplasty between simple loading conditions and loading conditions derived from activities of daily living, through the use of experimental and computational methods. The amount of micromotion at the …
-
Finite element analysis of a cementless proximal femoral stem in relation to early stem stability and interface bone strain
<p>The adequacy of assessing stems stability using only one femoral bone property was tested by varying the bone properties systematically and examining the resultant stem stability and interface strain. Unlike previous published studies which looked at the micromotion values only, the interface …
-
Optimization of distribution of porosity of a short metaphyseal femoral stem with respect to the strain field and the micromotion
Introduction: Short-stem total hip arthroplasty is a treatment method for hip osteoarthritis, but long-term complications such as stress shielding and aseptic loosening can lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective at reducing …
-
An articulated drill and hybrid tracking navigation system for orthopaedic surgery
… acetabular cup positioning and orientation, and femoral stem positioning. However, in robotic orthopaedic surgery with tracking and navigation system, the femoral stem insertion depends on hand-rasping method and confirmation of position by placing tracking marker at the neck shaft of femoral …
-
Μορφομετρική ανάλυση του άνω τριτημορίου του μηριαίου οστού στον ελληνικό πληθυσμό
… dimensions, which are necessary for femoral stem design in noncemented hip arthroplasties, were calculated with DICOM Viewer 2.1. image processing software. Each femur was sawn into horizontal slices corresponding to the same level as in CT and the above dimensions were manually …
-
The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems
… towards the premature loosening of the femoral stem. In order to improve the stress shielding characteristics of metallic femoral stems, stiffness configurations that offer more flexibility should be considered. This research has investigated the potential of more flexible and …
-
A three-dimensional finite element method for quantifying stress shielding following total hip replacement
… with total hip replacement is the loosening of femoral stem. A major cause of femoral stem loosening is believed to be stress shielding of the proximal femur following implantation. In order to ensure the long-term success of total hip replacement, minimization of stress shielding is desirable. …
-
The effect of surface roughness and a collar on fixation of cemented femoral stems in vivo / by Scott Andrew Brumby.
This thesis investigates the effect of femoral stem surface roughness and a collar on the fixation of cemented hip hemi-arthroplasty femoral stems in an in vivo sheep model up to nine months following implantation. Plain radiography, micromotion between prosthesis and bone during mechanical testing …
-
Optimising outcomes in primary total hip replacement
… of contention in contemporary THR concern<br/>stem fixation, bearing surfaces and infection.<br/><br/>Stem fixation<br/><br/>Patient age and activity influence the longevity of THR. This thesis will examine the<br/>evidence for femoral stem fixation, i.e. cemented or uncemented, according to …
-
Optimisation Of Fixation Methods For Vancouver Type B2 And B3 Periprosthetic Femoral Fracture Treatment
Periprosthetic femoral fractures (PFF) are a complication associated with total hip arthroplasty patients that can be both traumatic and challenging to treat. With the increasing age of the population and increasing prevalence of hip replacement surgery periprosthetic femoral fractures are expected …
-
Interactions between bio-tribocorrosion phenomena and cellular response of titanium-based femoral stems
In orthopedics, the loosening/failure of the femoral stem of hip implants is a major concern. In uncemented Ti-based implants, the tribochemical reactions occurring at the implant/bone interface due to micromotion are known to contribute to these failures. However, the bio-tribocorrosion behavior …
-
Surface Modifications to Enhance the Wear Resistance and the Osseo-integration Properties of Biomedical Ti-alloy
… focuses on improving the wear resistance of femoral head component and enhancing the osseo-integration properties of femoral stem component of a hip implant made of a new generation low modulus alloy, Ti-35Nb-7Zr-5Ta or TNZT. Different techniques that were adopted to improve the wear …
-
An Investigation on the Corrosion Susceptibilities of Multi-Alloy Total Hip Replacements.
… applications of the titanium alloy for the femoral stem and a cobalt alloy for the femoral head have been established.
-
Characterization of Sintered TiAl : A Mechanical Alloy for Use in the Design of a Total Artificial Hip
… is replacing. The focus for this study was the femoral stem of a total artificial hip and the material used in making it. This material must be strong, have a high damping capacity and an elastic modulus close to that of bone. In an attempt to produce a material which could fit all these …
-
Wear prediction in the acetabular component of hip implants
… of hip implants, the articulating surface of the femoral stem, faces the most wear. Wear prediction of the liner bearing surface is key in understanding revision rates. Wear depth is often done computationally using a using deterministic finite element analysis. Coupling finite element analysis …
-
Μικρής παρεμβατικότητας (MIS) προσπέλαση και υλικά (short stem) στην ολική αντικατάσταση της άρθρωσης του ισχίου
… (MIS), either MIS approaches or the use of short femoral stems. The objective of this doctoral thesis was the conduction of clinical research in order to investigate the effectiveness of the MINIMA® short stem and the MIS SuperPATH approach in primary THA. Thus, this doctoral thesis was cocncluded …