Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 40 for “"femoral stem"”.

  1. Computer-aided design of femoral stem prostheses

    In the design of femoral stem prostheses, both biologic factors and prosthetic design features influence the long-term performance of the implant. The analysis of all these influences is difficult, if not impossible, at the present time. This research presents a computational approach, using …

    rice Repository record for Computer-aided design of femoral stem prostheses (opens in a new tab)

  2. Accounting for parameter uncertainties in the prediction of porous femoral stem reliability

    … hip replacement surgery makes the reliability of femoral stems very important. Revision surgery due to aseptic loosening is one the most common reason for early failure. Aseptic loosening is reported to occur mainly due to stress shielding. Revision surgery can greatly hamper the standard and …

    ttu Repository record for Accounting for parameter uncertainties in the prediction of porous femoral stem reliability (opens in a new tab)

  3. Finite element modeling of a femoral stem in a total hip prosthesis

    … was produced to study of effects of stress on a femoral stem in a total hip prosthesis. Using the ANSYS General Purpose Finite Element Computer Program, a reproduction of the system was constructed for the loads acting on the hip joint at intervals of a walking cycle. With isotropic properties …

    njit Repository record for Finite element modeling of a femoral stem in a total hip prosthesis (opens in a new tab)

  4. A Virtual Method for Establishing Femoral Stem Position in Total Hip Arthroplasty

    … joint. Despite the success of these procedures, femoral stem misalignment remains an area that influences THA success. The relationship between the femoral stem geometry and implanted femoral stem size and orientation is underreported due to limitations in the collection of radiographic data used …

    denver Repository record for A Virtual Method for Establishing Femoral Stem Position in Total Hip Arthroplasty (opens in a new tab)

  5. Revision Total Hip Femoral Stem Micromotion and Statistical Shape Modeling of the Knee

    … to compare the amount of micromotion seen in the femoral stem in a revision total hip arthroplasty between simple loading conditions and loading conditions derived from activities of daily living, through the use of experimental and computational methods. The amount of micromotion at the …

    denver Repository record for Revision Total Hip Femoral Stem Micromotion and Statistical Shape Modeling of the Knee (opens in a new tab)

  6. Finite element analysis of a cementless proximal femoral stem in relation to early stem stability and interface bone strain

    <p>The adequacy of assessing stems stability using only one femoral bone property was tested by varying the bone properties systematically and examining the resultant stem stability and interface strain. Unlike previous published studies which looked at the micromotion values only, the interface …

    soton Download PDF for Finite element analysis of a cementless proximal femoral stem in relation to early stem stability and interface bone strain (opens in a new tab)

  7. Optimization of distribution of porosity of a short metaphyseal femoral stem with respect to the strain field and the micromotion

    Introduction: Short-stem total hip arthroplasty is a treatment method for hip osteoarthritis, but long-term complications such as stress shielding and aseptic loosening can lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective at reducing …

    greece Repository record for Optimization of distribution of porosity of a short metaphyseal femoral stem with respect to the strain field and the micromotion (opens in a new tab)

  8. An articulated drill and hybrid tracking navigation system for orthopaedic surgery

    … acetabular cup positioning and orientation, and femoral stem positioning. However, in robotic orthopaedic surgery with tracking and navigation system, the femoral stem insertion depends on hand-rasping method and confirmation of position by placing tracking marker at the neck shaft of femoral …

    strathclyde Repository record for An articulated drill and hybrid tracking navigation system for orthopaedic surgery (opens in a new tab)

  9. Μορφομετρική ανάλυση του άνω τριτημορίου του μηριαίου οστού στον ελληνικό πληθυσμό

    … dimensions, which are necessary for femoral stem design in noncemented hip arthroplasties, were calculated with DICOM Viewer 2.1. image processing software. Each femur was sawn into horizontal slices corresponding to the same level as in CT and the above dimensions were manually …

    greece Repository record for Μορφομετρική ανάλυση του άνω τριτημορίου του μηριαίου οστού στον ελληνικό πληθυσμό (opens in a new tab)

  10. The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems

    … towards the premature loosening of the femoral stem. In order to improve the stress shielding characteristics of metallic femoral stems, stiffness configurations that offer more flexibility should be considered. This research has investigated the potential of more flexible and …

    wlv Repository record for The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems (opens in a new tab) Download file for The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems (opens in a new tab)

  11. A three-dimensional finite element method for quantifying stress shielding following total hip replacement

    … with total hip replacement is the loosening of femoral stem. A major cause of femoral stem loosening is believed to be stress shielding of the proximal femur following implantation. In order to ensure the long-term success of total hip replacement, minimization of stress shielding is desirable. …

    rice Repository record for A three-dimensional finite element method for quantifying stress shielding following total hip replacement (opens in a new tab)

  12. The effect of surface roughness and a collar on fixation of cemented femoral stems in vivo / by Scott Andrew Brumby.

    This thesis investigates the effect of femoral stem surface roughness and a collar on the fixation of cemented hip hemi-arthroplasty femoral stems in an in vivo sheep model up to nine months following implantation. Plain radiography, micromotion between prosthesis and bone during mechanical testing …

    adelaide Repository record for The effect of surface roughness and a collar on fixation of cemented femoral stems in vivo / by Scott Andrew Brumby. (opens in a new tab)

  13. Optimising outcomes in primary total hip replacement

    … of contention in contemporary THR concern<br/>stem fixation, bearing surfaces and infection.<br/><br/>Stem fixation<br/><br/>Patient age and activity influence the longevity of THR. This thesis will examine the<br/>evidence for femoral stem fixation, i.e. cemented or uncemented, according to …

    bristol Repository record for Optimising outcomes in primary total hip replacement (opens in a new tab) Download PDF for Optimising outcomes in primary total hip replacement (opens in a new tab)

  14. Optimisation Of Fixation Methods For Vancouver Type B2 And B3 Periprosthetic Femoral Fracture Treatment

    Periprosthetic femoral fractures (PFF) are a complication associated with total hip arthroplasty patients that can be both traumatic and challenging to treat. With the increasing age of the population and increasing prevalence of hip replacement surgery periprosthetic femoral fractures are expected …

    whiterose Download PDF for Optimisation Of Fixation Methods For Vancouver Type B2 And B3 Periprosthetic Femoral Fracture Treatment (opens in a new tab)

  15. Interactions between bio-tribocorrosion phenomena and cellular response of titanium-based femoral stems

    In orthopedics, the loosening/failure of the femoral stem of hip implants is a major concern. In uncemented Ti-based implants, the tribochemical reactions occurring at the implant/bone interface due to micromotion are known to contribute to these failures. However, the bio-tribocorrosion behavior …

    minho-thes Repository record for Interactions between bio-tribocorrosion phenomena and cellular response of titanium-based femoral stems (opens in a new tab)

  16. Surface Modifications to Enhance the Wear Resistance and the Osseo-integration Properties of Biomedical Ti-alloy

    … focuses on improving the wear resistance of femoral head component and enhancing the osseo-integration properties of femoral stem component of a hip implant made of a new generation low modulus alloy, Ti-35Nb-7Zr-5Ta or TNZT. Different techniques that were adopted to improve the wear …

    unt Repository record for Surface Modifications to Enhance the Wear Resistance and the Osseo-integration Properties of Biomedical Ti-alloy (opens in a new tab)

  17. An Investigation on the Corrosion Susceptibilities of Multi-Alloy Total Hip Replacements.

    … applications of the titanium alloy for the femoral stem and a cobalt alloy for the femoral head have been established.

    uab Repository record for An Investigation on the Corrosion Susceptibilities of Multi-Alloy Total Hip Replacements. (opens in a new tab)

  18. Characterization of Sintered TiAl : A Mechanical Alloy for Use in the Design of a Total Artificial Hip

    … is replacing. The focus for this study was the femoral stem of a total artificial hip and the material used in making it. This material must be strong, have a high damping capacity and an elastic modulus close to that of bone. In an attempt to produce a material which could fit all these …

    marquette Repository record for Characterization of Sintered TiAl : A Mechanical Alloy for Use in the Design of a Total Artificial Hip (opens in a new tab)

  19. Wear prediction in the acetabular component of hip implants

    … of hip implants, the articulating surface of the femoral stem, faces the most wear. Wear prediction of the liner bearing surface is key in understanding revision rates. Wear depth is often done computationally using a using deterministic finite element analysis. Coupling finite element analysis …

    ttu Repository record for Wear prediction in the acetabular component of hip implants (opens in a new tab)

  20. Μικρής παρεμβατικότητας (MIS) προσπέλαση και υλικά (short stem) στην ολική αντικατάσταση της άρθρωσης του ισχίου

    … (MIS), either MIS approaches or the use of short femoral stems. The objective of this doctoral thesis was the conduction of clinical research in order to investigate the effectiveness of the MINIMA® short stem and the MIS SuperPATH approach in primary THA. Thus, this doctoral thesis was cocncluded …

    greece Repository record for Μικρής παρεμβατικότητας (MIS) προσπέλαση και υλικά (short stem) στην ολική αντικατάσταση της άρθρωσης του ισχίου (opens in a new tab)

Page 1 of 2