Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 22 for “"femoral stems"”

  1. A study comparing the primary stability of two uncemented, modular titanium femoral stems

    … of tapered, fluted, modular, titanium-alloy stems. The Redapt® stem featured a novel flute configuration and chamfered tip. It was hypothesised that this would improve axial and rotational stability compared to the Modular Restoration® control stem. Each stem was implanted into one of 7 …

    ucl Repository record for A study comparing the primary stability of two uncemented, modular titanium femoral stems (opens in a new tab)

  2. Finite element design of a mechanical testing method for polymer composite femoral stems

    Polymer composite femoral stems do not have a standardized in vitro mechanical testing method. The testing device for metallic stems, which simulates proximal resorption of the femur, is inappropriate for composite stems, which they are expected to reduce or prevent proximal resorption. The …

    ohiolink Repository record for Finite element design of a mechanical testing method for polymer composite femoral stems (opens in a new tab)

  3. Interactions between bio-tribocorrosion phenomena and cellular response of titanium-based femoral stems

    In orthopedics, the loosening/failure of the femoral stem of hip implants is a major concern. In uncemented Ti-based implants, the tribochemical reactions occurring at the implant/bone interface due to micromotion are known to contribute to these failures. However, the bio-tribocorrosion behavior …

    minho-thes Repository record for Interactions between bio-tribocorrosion phenomena and cellular response of titanium-based femoral stems (opens in a new tab)

  4. The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems

    … towards the premature loosening of the femoral stem. In order to improve the stress shielding characteristics of metallic femoral stems, stiffness configurations that offer more flexibility should be considered. This research has investigated the potential of more flexible and …

    wlv Repository record for The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems (opens in a new tab)

  5. The effect of surface roughness and a collar on fixation of cemented femoral stems in vivo / by Scott Andrew Brumby.

    This thesis investigates the effect of femoral stem surface roughness and a collar on the fixation of cemented hip hemi-arthroplasty femoral stems in an in vivo sheep model up to nine months following implantation. Plain radiography, micromotion between prosthesis and bone during mechanical testing …

    adelaide Repository record for The effect of surface roughness and a collar on fixation of cemented femoral stems in vivo / by Scott Andrew Brumby. (opens in a new tab)

  6. The use of 3D surface analysis techniques to investigate the wear of matt surface finish femoral stems in total hip replacement

    … the loosening and failure of matt surface finish femoral stems. By examining stems which have been explanted from patients, a method of wear classification has been developed, and also 3D surface measurement techniques have been employed to quantify wear through parametric characterisation and …

    huddersfield

  7. Accounting for parameter uncertainties in the prediction of porous femoral stem reliability

    … hip replacement surgery makes the reliability of femoral stems very important. Revision surgery due to aseptic loosening is one the most common reason for early failure. Aseptic loosening is reported to occur mainly due to stress shielding. Revision surgery can greatly hamper the standard and …

    ttu Repository record for Accounting for parameter uncertainties in the prediction of porous femoral stem reliability (opens in a new tab)

  8. Modularity of metal-on-metal total hip Arthroplasty: a flawed concept?

    … systematic review performed recently on custom femoral stems; a better option than modular neck stems? Study 1 reported on corrosion found on the backside of two different modular metal liners, each highlighting a different corrosion pattern, but both designs illustrate greater corrosion at the …

    east-anglia Repository record for Modularity of metal-on-metal total hip Arthroplasty: a flawed concept? (opens in a new tab)

  9. The use of 3D-CT Planning and Patient Specific Instrumentation in Total Hip Arthroplasty: Pre-, Intra- and Post-Operative Evaluation

    … the role of 3D-CT planning and PSI in terms of femoral stem implantation through pre- and post-operative 3D-CT image analysis in primary THA. 3D-CT planning accurately predicted the femoral stem size (96% within one size) and femoral offsets in uncemented THA. Predicting Prosthetic Femoral …

    ucl Repository record for The use of 3D-CT Planning and Patient Specific Instrumentation in Total Hip Arthroplasty: Pre-, Intra- and Post-Operative Evaluation (opens in a new tab)

  10. Influence of postoperative treatment, surface treatment and stem design on the outcome of primary total hip arthroplasty

    … The main intention was to study anteverted femoral stems. Material and methods: Study 1: 43 patients who received an uncemented and hydroxy-apatite coated prosthesis with an anteverted stem were randomized to partial or full weight bearing and followed for 1 year with radiostereometry. The …

    goteborg Repository record for Influence of postoperative treatment, surface treatment and stem design on the outcome of primary total hip arthroplasty (opens in a new tab)

  11. Dynamic Ball & Socket Joint Force Simulator

    … a MTS 858 Mini Bionix machine. The design allows femoral components to be tested dynamically in three dimensions with four degrees of freedom. Two rotary actuators turn the distal end of the femur around perpendicular axes while the linear actuator applies a downward force through the centroid of …

    ku Repository record for Dynamic Ball & Socket Joint Force Simulator (opens in a new tab)

  12. Η χρήση των βραχέων μεταφυσιακών στυλεών στην πρωτοπαθή οστεοαρθρίτιδα του ισχίου: ανάλυση πεπερασμένων στοιχείων (finite element analysis), πειραματική εμβιομηχανική μελέτη (experimental biomechanichal testing) και προοπτική, τυχαιοποιημένη συγκριτική μελέτη δυο διαφορετικών στυλεών σε ασθενείς με πρωτοπαθή οστεοαρθρίτιδα του ισχίου

    … bone and soft-tissue-sparing surgery. Regarding femoral implants, different stem designs have been developed as an alternative to conventional stems, and there is a renewed interest towards short versions of uncemented femoral implants. The proposed study aims to compare the biomechanical …

    greece Repository record for Η χρήση των βραχέων μεταφυσιακών στυλεών στην πρωτοπαθή οστεοαρθρίτιδα του ισχίου: ανάλυση πεπερασμένων στοιχείων (finite element analysis), πειραματική εμβιομηχανική μελέτη (experimental biomechanichal testing) και προοπτική, τυχαιοποιημένη συγκριτική μελέτη δυο διαφορετικών στυλεών σε ασθενείς με πρωτοπαθή οστεοαρθρίτιδα του ισχίου (opens in a new tab)

  13. Optimization of distribution of porosity of a short metaphyseal femoral stem with respect to the strain field and the micromotion

    … aseptic loosening can lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective at reducing stress shielding; however, there is a lack of research on customized porous distributions in stem coatings. This study aimed to optimize the porous …

    patras-thes Repository record for Optimization of distribution of porosity of a short metaphyseal femoral stem with respect to the strain field and the micromotion (opens in a new tab)

  14. Interface micromotion in cementless hip prostheses.

    … reported failure modes of cementless hip stems are loosening and thigh pain both are attributed to the relative motion at the bone-implant interface due to failure to achieve sufficient primary fixation. The main aim of the current study is to investigate, using Finite Element Analysis, …

    ucl Repository record for Interface micromotion in cementless hip prostheses. (opens in a new tab)

  15. Optimization of distribution of porosity of a short metaphyseal femoral stem with respect to the strain field and the micromotion

    … aseptic loosening can lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective at reducing stress shielding; however, there is a lack of research on customized porous distributions in stem coatings. This study aimed to optimize the porous …

    greece Repository record for Optimization of distribution of porosity of a short metaphyseal femoral stem with respect to the strain field and the micromotion (opens in a new tab)

  16. Mechanical Behaviour of Ti6Al4V Lattice Structures Fabricated by Electron Beam Powder Bed Fusion

    … an exploratory study has been conducted, porous femoral stem has been designed based on the findings in SC lattices to meet the required fatigue life of 5×10^6 cycles specified the international standard while maintaining the fully porous surface for bone ingrowth. FE simulations and fracture …

    auckland-tech Repository record for Mechanical Behaviour of Ti6Al4V Lattice Structures Fabricated by Electron Beam Powder Bed Fusion (opens in a new tab)

  17. Μορφομετρική ανάλυση του άνω τριτημορίου του μηριαίου οστού στον ελληνικό πληθυσμό

    … dimensions, which are necessary for femoral stem design in noncemented hip arthroplasties, were calculated with DICOM Viewer 2.1. image processing software. Each femur was sawn into horizontal slices corresponding to the same level as in CT and the above dimensions were manually …

    greece Repository record for Μορφομετρική ανάλυση του άνω τριτημορίου του μηριαίου οστού στον ελληνικό πληθυσμό (opens in a new tab)

  18. Corrosion of Ti-based bulk metallic glasses for small diameter dental implants

    … and local acidity have been found for cemented femoral stems and modular orthopaedic Ti implants. There is concern that MACC may also be a risk for dental implants, so it is important to be able to evaluate risk in quantitative way. A new device was developed that can retain the local acidity …

    birmingham Repository record for Corrosion of Ti-based bulk metallic glasses for small diameter dental implants (opens in a new tab)

  19. Design and evaluation of CAD-CAM custom-made hip prosthesis

    … the geometry of the stem and its fit within the femoral canal. Particularly where the femoral canals are severely distorted such as in CDH or JRA, the femoral canal can not be accurately fitted by conventional hip stems. The condition of the femur on revision is highly variable, making it …

    ucl Repository record for Design and evaluation of CAD-CAM custom-made hip prosthesis (opens in a new tab)

Page 1 of 2