Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 23 for “"fetal ECG"”.
-
Modelling the fetal ECG
Promotores : A. van Oosterom en T. Eskes
-
Design of a biomedical system for fetal ECG monitoring
A mobile, non-intrusive, biomedical system for fetalECG monitoring has been designed. By using electrodes placedon the belly of a pregnant woman, the system is capable ofmeasuring the electrocardiograph of the fetus without the need oftrained personnel. Because the system uses Bluetooth Smart, …
-
Blind separation for fetal ECG from single mixture by SVD and ICA
… a novel blind-sourceseparation method to extract fetal ECG from a single-channelsignal measured on the abdomen of the mother. The signal is amixture of the fetal ECG, the maternal ECG and noise. The key ideais to compute the spectrogram of the original signal, and then usean assumption of …
-
Deep learning applied to non-invasive ECG pregnancy monitoring : fetal ECG recovery and QRS complex detection
… situations is typically performed by measuring fetal heart rate (fHR), often in conjunction with uterine contractions (UC). Given the limitations of established monitoring methods in clinical practice, non-invasive electrocardiography (niECG) emerges as a promising alternative. This technique …
-
NUOVI METODI DI ANALISI DELL'ELETTROCARDIOGRAMMA FETALE ACQUISITO PER VIA TRANS-ADDOMINALE
… OF ANALYSIS OF TRANS-ABDOMINALLY ACQUIRED FETAL ELECTROCARDIOGRAM Background. Our group was one of the first to apply Phase Rectified Signal Averaging (PRSA) analysis in obstetric field by analyzing fetal ECG acquired non-invasively by trans-abdominal ECG. PRSA is a new method that …
-
Denoise high dimensional dataset with complicated noise and its clinical applications
… rate.</p><p>We apply eOptShrink to recover fetal electrocardiogram (ECG) for both the fetal heart rate analysis and morphological analysis of its waveform from two or three trans-abdominal maternal ECG channels. </p><p>For the fetal heart rate analysis, the algorithm is evaluated on publicly …
-
Extraction and Detection of Fetal Electrocardiograms from Abdominal Recordings
The non-invasive fetal ECG (NIFECG), derived from abdominal surface electrodes, offers novel diagnostic possibilities for prenatal medicine. Despite its straightforward applicability, NIFECG signals are usually corrupted by many interfering sources. Most significantly, by the maternal ECG (MECG), …
-
Independent component analysis for maternal-fetal electrocardiography
… problems in this area is the extraction of the fetal heartbeat from an electrocardiogram in which it is overshadowed by a strong maternal heartbeat. This thesis presents a study of a signal separation technique called independent component analysis (ICA), in order to assess its suitability for …
-
Improving Maternal and Fetal Cardiac Monitoring Using Artificial Intelligence
… monitoring methods, such as electrocardiogram (ECG) and photoplethysmography (PPG), are commonly performed. Although there are several methods for monitoring fetal and maternal health, research is currently underway to enhance the mobility, accuracy, automation, and noise resistance of these …
-
Algorithms and systems for home telemonitoring in biomedical applications
… telemonitoring application considered is the fetal electrocardiography. Non-invasive fetal electrocardiography is the recording of the fetal heart electrical activity using electrodes placed on the maternal abdomen. It can provide important diagnostic parameters, such as the beat-to-beat heart …
-
Fetal Magnetic Resonance Oximetry
Fetal magnetic resonance oximetry has the potential to improve upon current, ultrasound-based methods for the diagnosis of fetal hypoxia. Unlike ultrasound, which detects hypoxia by measurement of adaptive blood fow changes, MRI is directly sensitive to blood oxygen content. This phenomenon is …
-
Non-invasive fetal electrocardiogram classification using spatial correlation
… of premature birth a challenging proposition. Fetal monitoring can support the physician in making the often vitally important decision whether or not to induce labor artificially. Nowadays, the most common used technique for fetal monitoring is cardiotocography (CTG). However, information from …
-
Advanced Source Reconstruction and Volume Conductor Modeling for Fetal Magnetocardiography
… failure. Compared to adult cardiac monitoring, fetal electrophysiological heart monitoring using fetal ECG is extremely difficult due to the low signal amplitude and interferences from the maternal cardiac signal and to the complex environment inside the mother's womb. This problem is even worse …
-
Novel approaches to improving the monitoring and mechanistic understanding of intrahepatic cholestasis of pregnancy
… bile acid (TSBA) concentrations and adverse fetal outcomes such as preterm labour (PTL) and intrauterine death (IUD); the risk of which is directly associated with the degree of maternal TSBA derangement. Assays for measurement of TSBA concentration are not readily available at every clinical …
-
Intelligent fetal monitoring and decision support in the management of labour
… labour is inferred from the continuous plot of fetal heart rate and uterine contractions (cardiotocogram, CTG). This can be _ difficult to interpret which results in both unnecessary intervention and a failure to intervene when necessary causing potentially preventable neurological damage and …
Page 1 of 2