Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 34 for “"field uniformity"”.
-
Identification of the Corona Point in Point-to-Plane Geometries in Atmospheric Air
The minimum sustaining electric field for streamer propagation is directly correlated to the minimum electric field at the corona point. Corona is a product of non-uniform electric fields; the onset of corona occurs before electrical breakdown. As electric fields become increasingly uniform the …
-
CHARACTERIZATION AND HANDLING OF UNCERTAINTIES IN EMC/EMI MEASUREMENTS
… uncertainty (MU) is an important topic in EMC field. The characterisation of MU aims to provide an appropriate tolerance/budget to the test laboratories, which will be associated with the measurement results of the equipment under test (EUT). It is the purpose of this thesis to characterise the …
-
Alternative winding patterns for twisted solenoid coils with improved characteristics for TRASE MRI
… imaging modality; however, conventional high-field MRI systems rely on strong static magnetic fields and gradient coils, resulting in high system complexity, power consumption, acoustic noise, and limited accessibility. The development of low-field MRI systems has the potential to alleviate …
-
Apparatus for Inertial Sensing with Cold Atoms
… include a finite-element model of the magnetic field coil setup used in the experimental apparatus, as well as the design and construction of a hermetically-sealed diode laser system with excellent long-term frequency stability. Additionally, a direct digital synthesis-based frequency generator …
-
Investigation of Swirl Assisted Colorless Distributed Combustion (CDC) for Gas Turbine Application
… method to enhance flame stability and thermal field uniformity, increase combustion efficiency and reduce pollutants emission, including noise. The focus of this thesis is to investigate swirl-assisted distributed combustion at high thermal intensity for gas turbine application. This thesis …
-
THE CORONA-TO-SPARK TRANSITION AND ITS DEPENDENCE ON ELECTRIC FIELD NON-UNIFORMITY
… understanding gaseous breakdown in non-uniform fields. The degree of uniformity in the geometry determines both the onset of corona as well as the eventual spark transition. In a highly non-uniform geometry, the onset of corona precedes the development of a spark. However, in weakly non-uniform …
-
A TEM cell design to study electromagnetic radiation exposure from cellular phones
… experiments and lab simulations. The electric field distribution was studied with such varying parameters as the cellular phone position, polarization, dialing type, and dialing frequency. Analysis showed that the electric field uniformity can be improved with either the use of a shorter signal …
-
Developing the Precision Magnetic Field for the E989 Muon g–2 Experiment
… precession frequencies defined by the magnetic field, proton precession and muon precession. The value of $(g\hbox{--}2)_\mu$ is derived from a relationship between the two frequencies. The precision of magnetic field measurements and the overall magnetic field uniformity achieved over the muon …
-
Enhancements to Uniformity of Magnetic Fields at the SNS nEDM Experiment
… requires an extremely uniform magnetic field to maintain 3He polarization during transit to the measurement cell. The Magnetic Shield Enclosure (MSE) coil provides the required field. However, the superconducting shield distorts the MSE field. This thesis discusses a magnetic cloak for …
-
Portable atom interferometry: investigation on magnetic shielding techniques for compact quantum sensors
… magnetic shielding design, aiming to reach a field attenuation factor of the order of 103, by mu-metal. The research was extended to alternative shielding techniques with the intention to push current technology towards next generation portable atomic sensors. Initially, Metglas foil was used …
-
Radiator modeling and design for MRI safety assessment
… the most performed procedure in clinic, higher fields such as 3 T and 7 T are gaining more popularity because of their increased sensitivity and spatial resolution. However, the increased frequency caused the degradation of the field uniformity. To compensate the field distortion, a so-called RF …
-
Study on the remediation of organic soil contaminated with polychlorinated biphenyls using a variable frequency microwave furnace
… frequencies of the microwave range is the non-uniformity of the electromagnetic field. In this thesis a Variable Frequency Microwave Furnace (operating between 2.40 and 7.50 GHz) is used to improve the uniformity of the field. A new method is used to map the field uniformity in a fixed and …
-
A Compact, Reconfigurable Penning Trap for Quantum Applications
… physics. They use static electric and magnetic fields to confine charged particles in 3-dimensional space. Most Penning traps employ a magnetic field produced by a large superconducting coil. However, in this thesis I detail the design and creation of compact, reconfigurable permanent magnet …
-
SIMULATION STUDIES OF MVDC POWER CABLE FOR ALL ELECTRIC AIRCRAFTS
… In this paper, the temperature and electric field across the insulator of the 5 kV DC Southwire cable is simulated up to 10 hours of cable operation. Furthermore, the temperature of the cable is shown with and without the presence of the chamber box. The other issue of the MVDC power cable is …
-
THE DESIGN OF PRIMARY HOLDING MAGNET FOR THE LANL NEUTRON ELECTRIC DIPOLE MOMENT EXPERIMENT
… 10−27 e·cm (68 % CL). A highly uniform magnetic field is key to achieving this sensitivity for the nEDM measurement by reducing the systematic uncertainties associated with the magnetic field non-uniformity. The B0 coil was designed to achieve a field uniformity of < 0.3 nT·m−1 at a nominal …
-
Advanced RF Hardware Solutions for Improved Imaging Performance and Safety in Ultra-High and Very-Low-Field MRI
… (MRI) continues to evolve across a wide range of field strengths, from ultra-high-field (7T) to very-low-field (70 mT) systems. Despite their clinical potential, each regime presents unique challenges in RF coil design, affecting imaging quality, patient safety, and system accessibility. This …
-
Improving the gain, noise, and dark current performance of AlInAsSb digital alloy photodiodes grown by molecular beam epitaxy
… greatly in device operation owing to electric field uniformity in the intrinsic regions of the material. Additionally, device design that was previously handcuffed by relatively high and varying unintentional doping was afterwards enabled. Here we also report these device improvements; they …
-
Characterization of the magnetically shielded room for the neutron electric dipole moment experiment at TRIUMF
… the Ramsey technique of separated oscillatory fields. This requires highly uniform electric and magnetic fields, achieved within a Magnetically Shielded Room (MSR), which isolates the precession field from external interference. However, magnetic field inhomogeneities are a major source of …
-
Magnetic Resonance RF Coil Modeling and Simulation: Analysis of Biot-Savart Law and Frequency Response Methods
… imaging provides a method to place a near-field antenna in close proximity with the anatomy of imaging interest and enables substantial improvements in the signal-to-noise ratios (SNR) and image quality relative to the standard whole-volume coils. This thesis focuses on the methods and …
-
Measurement of shielding in electrically large metallic enclosures
… and are also lacking in a full analysis of the field distributions within the enclosure. The work presented here uses the IEEE 299.1 draft standard as a base and investigates different methods of obtaining the SE, as well as looking at making the measurement more applicable to physically small …
Page 1 of 2