Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 10 of 10 for “"finger plethysmography"”
-
Sympathetic Neural Responses to Acute Thermal Sensations
… (12 total trials). Continuous blood pressure (finger plethysmography), heart rate (electrocardiography), and MSNA (via microneurography) were recorded throughout all trials. Data was assessed with a Shapiro-Wilk test and log transformations were utilized for non-normal distributed data. T-tests …
-
The Impact of Very Short-term Variability of Blood Pressure in Outcome after Successful Thrombectomy
… systolic blood pressure values recorded by finger plethysmography with Finometer device. Outcomes included independence at 90 days (modified Rankin scale 0-2) and the initial clinical response to mechanical thrombectomy. Results: We included 121 patients. Increased BPV at high frequencies …
-
The Longitudinal Associations Between Endothelial Function and Diabetes Type II and Diabetes Related Outcomes in People with No Major Non-Communicable Chronic Diseases: A Systematic Review
… endothelial function, flow-mediated dilation and finger plethysmography. Study selection: Longitudinal studies and cohort/placebo/control group of interventions studies with non-invasive endothelial function measures—flow mediated dilation (FMD) and reactive hyperemia index (RHI)—at the start of …
-
Neuroprotective Effects of Cannabidiol Following Concussion: A Case Study
… responses, and electrocardiography (ECG) and finger plethysmography to record continuous cardiovascular responses. End-tidal carbon dioxide was measured using a breath-by-breath capnograph. The protocol consisted of: 5-minute sitting rest, 6 breaths·minute-1 paced breathing maneuver, a …
-
The Influence of Carbon Monoxide on Vascular Reactivity
… of heart rate (ECG), mean arterial pressure (finger plethysmography), brachial artery diameter (B-mode ultrasound), forearm blood flow (FBF) (duplex ultrasound) and vascular conductance (FVC) (calculated from mean arterial pressure and FBF) in 19 young healthy volunteers (10 females) before …
-
The effect of a single session of intermittent hypoxia on erythropoietin and oxygen-carrying capacity
… oxygen saturation, and hemodynamics, using finger plethysmography, were continuously assessed during the intervention. Erythropoietin levels were measured before and two hours following the completion of the protocol. Hemoglobin mass was assessed using the carbon monoxide rebreathing …
-
Walking with leg blood flow restriction : wide-rigid cuffs vs. narrow-elastic bands
… and heart rate were measured continuously using finger plethysmography. Blood lactate concentration, rating of perceived exertion (RPE), flow-mediated dilation (index of endothelium-dependent vasodilation), and cardio-ankle vascular index (measure of arterial stiffness) were assessed before and …
-
Cerebral Blood Flow Response to Posture Transition and Walking in Older Adults with Heart Failure
… walking at a self-selected normal pace. Portable finger plethysmography measured central hemodynamics, portable capnography measured partial pressure end-tidal carbon dioxide (PETCO2), portable transcranial Doppler ultrasound measured cerebral blood flow velocity (CBFV), and near infrared …
-
Peripheral artery endothelial function responses to altered blood flow in humans
… within-subject time control (CON). Non-invasive finger plethysmography was used to measure heart rate (HR) and blood pressure (BP) throughout the testing sessions. Ultrasonography was used to obtain measures of blood velocity and arterial diameter from the brachial artery of both limbs throughout …
-
Auswirkungen der nächtlichen Hypoxie beim Patienten mit moderatem obstruktiven Schlafapnoesyndrom auf die Endothelfunktion
… und der Gefäßsteifigkeit mittels Fingerplethysmographie (EndoPAT™ 2000, Itamar). Im Anschluss wurde eine mindestens 6-stündige kardiorespiratorische Polysomnographie durchgeführt, um unmittelbar nach Wecken des Probanden eine zweite EndoPAT™-Messung durchzuführen. Es herrschten …