  1. Simplified Analysis of Flat-Plate Buildings During Fire Exposure

    … in the field. Elevated temperatures caused by fires degrade the mechanical properties of concrete and steel bars and introduce new strains, including thermal and transient strains. An RC flat plate slab is not entirely free to move during temperature variations, which is attributed to the …

    uwo Repository record for Simplified Analysis of Flat-Plate Buildings During Fire Exposure (opens in a new tab)

  2. Air gaps in protective clothing during flash fire exposure

    … and applications to provide protection against fire exposure. Exposure to fire can result in skin burn injuries that range from first-degree to third-degree burn injury depending on the exposure intensity and duration. Within the firefighting community, and especially the petroleum and …

    sask Repository record for Air gaps in protective clothing during flash fire exposure (opens in a new tab)

  3. Residual response of reinforced concrete beams following fire exposure

    … concrete (RC) structures possess inherent fire resistance due to relatively low thermal conductivity, high thermal capacity, and slower strength degradation of concrete with temperature. Nonetheless, fire exposure results in varying reduction in strength and stiffness RC members because of …

    msu Repository record for Residual response of reinforced concrete beams following fire exposure (opens in a new tab)

  4. Structural Performance of Ordinary and Laminated Glass during Fire Exposure

    … inside and outside environment. Glass has low fire resistance and can quickly break during fire events. This creates new vents, which increase the oxygen supply and promote the flashover phenomenon. Existing methods for evaluating the structural fire safety of glass require expensive …

    uwo Repository record for Structural Performance of Ordinary and Laminated Glass during Fire Exposure (opens in a new tab)

  5. Simplified Modeling of Bonded Prestressed High Strength Concrete Girders during Fire Exposure

    To evaluate the behavior of structures exposed to fire and estimate their structural fire resistance, engineers need design tools to overcome the complexities associated with structural analysis during fire exposure. These complexities include the uneven distribution of temperature within the …

    uwo Repository record for Simplified Modeling of Bonded Prestressed High Strength Concrete Girders during Fire Exposure (opens in a new tab)

  6. Analysis of the behaviour of liquid hydrogen (LH2) tanks under fire exposure

    … their widespread adoption. Despite insulation, fire tests have shown LH₂ tanks may fail catastrophically under fire exposure. This was largely attributed to MLI degradation, leaving the tank unprotected. However, the few fire tests on LH₂ tanks and the lack of investigations into the MLI …

    bologna Embargoed

  7. Studies of Wildland Fires: Inclined Flame Instabilities and Fire Exposure to Structures

    … work investigates two aspects of the wildland fire problem: instabilities occurring in inclined laminar flames and the coupling between fire exposure and structure loss. The first study analyzes the structure and stability of a laminar diffusion flame that forms either on the topside or the …

    maryland Repository record for Studies of Wildland Fires: Inclined Flame Instabilities and Fire Exposure to Structures (opens in a new tab)

  8. Performance of Post-Tensioned Timber and Engineered Timber Adhesives with Fire Exposure

    … in FEM software Abaqus to model PT timber in fire conditions, with highly promising results. Beam failure times were modelled within 5%, and load-deflection behaviour and failure mechanisms were accurately demonstrated. Additionally, the performance of timber adhesives after fire damage was …

    carleton Repository record for Performance of Post-Tensioned Timber and Engineered Timber Adhesives with Fire Exposure (opens in a new tab)

  9. The Mediational Role of Resource Loss between Residential Fire Exposure and Psychological Distress

    The relationship between exposure to trauma and the development of both Posttraumatic Stress Disorder (PTSD) and general distress has been widely discussed in the empirical literature. However, relatively little attention has been paid to the specific processes through which trauma exposure leads …

    vt Repository record for The Mediational Role of Resource Loss between Residential Fire Exposure and Psychological Distress (opens in a new tab)

  10. Computational Study of Highway Bridges Structural Response Exposed to a Large Fire Exposure

    The exposure from a localized vehicle fire has been observed to produce excessive damage onto highway bridge structural elements including complete collapse of the infrastructure. The occurrence of a fire beneath a bridge can lead to significant economic expense and loss of service even if the …

    vt Repository record for Computational Study of Highway Bridges Structural Response Exposed to a Large Fire Exposure (opens in a new tab)

  11. Microstructure-based Constitutive Models for Residual Mechanical Behavior of Aluminum Alloys after Fire Exposure

    … marine crafts, and off-shore platforms. The post-fire (residual) integrity of aluminum structures is of particular concern as a severe degradation in mechanical properties may occur without catastrophic failure, even for short duration, low intensity fires. The lack of research characterizing …

    vt Repository record for Microstructure-based Constitutive Models for Residual Mechanical Behavior of Aluminum Alloys after Fire Exposure (opens in a new tab)

  12. A Computational Study of the Potential for LNG Tanker Polystyrene Foam Insulation Failure under Fire Exposure

    … insulation failure caused by a large ship fire. Experiments were done investigating the nature of polystyrene’s thermal degradation, notably by Brauman, Chen, and Matzinger and Butler. A large scale investigation was also performed by Sandia National Laboratory. However, computational …

    arkansas Repository record for A Computational Study of the Potential for LNG Tanker Polystyrene Foam Insulation Failure under Fire Exposure (opens in a new tab)

  13. Residual axial capacity of fire exposed reinforced concrete columns

    "Fire represents one of the most severe environmental loading conditions that a structure may experience during its design lifetime. Reinforced Concrete (RC) structural members can experience some level of damage following moderate or severe fire exposure. To ensure safe future use of the …

    msu Repository record for Residual axial capacity of fire exposed reinforced concrete columns (opens in a new tab)

  14. Effect of elevated temperature and fire on structural elements retrofitted by carbon fiber reinforced polymer composites

    … investigation for evaluating effects of fire exposure on properties of structural elements retrofitted by carbon fiber reinforced polymers. Mechanical properties of CFRP-strengthened reinforced concrete members, protected with secondary insulation, were investigated, before and after …

    fau Repository record for Effect of elevated temperature and fire on structural elements retrofitted by carbon fiber reinforced polymer composites (opens in a new tab)

  15. Strategies for enhancing the fire resistance of steel framed structures through composite construction

    … structural performance under ambient and fire conditions. However, the beneficial effects of composite action are not often taken into consideration in evaluating the fire response of structures due to poor understanding on the behavior of composite structural systems, and lack of design …

    msu Repository record for Strategies for enhancing the fire resistance of steel framed structures through composite construction (opens in a new tab)

  16. Structural Performance of Glass Façades Exposed to Fire

    … inadequate performance of glass façades during fire incidents, which accelerates the spread and severity of the fire. This concern is magnified by the recent worldwide increase in wildfires. Thus, it is critical for engineers to be able to assess the structural performance of glass façades at …

    uwo Repository record for Structural Performance of Glass Façades Exposed to Fire (opens in a new tab)

  17. Material properties related to fire spalling of concrete

    … 100 years of research, the fundamentals of fire spalling of concrete are not yet fully understood. Many different theories exist, each trying to describe the coupling between different phenomenon leading to fire spalling. Some of these phenomenon have been investigated and are presented in …

    lund Repository record for Material properties related to fire spalling of concrete (opens in a new tab)

  18. Response of reinforced concrete columns under temperature induced transient creep strain

    … creep deformations in later stages of fire exposure and are susceptible to failure due to temperature induced creep strains. Fire in a concrete structure can burn for several hours, and temperatures in concrete and reinforcing steel can exceed 500 °C. At such temperatures, high levels …

    msu Repository record for Response of reinforced concrete columns under temperature induced transient creep strain (opens in a new tab)

  19. INFLUENCE OF WEB THICKNESS AND CONCRETE COVER ON THE FIRE RESISTANCE OF AASHTO TYPE IV PRESTRESSED CONCRETE BRIDGE GIRDERS

    Bridge fires caused by vehicle accidents, fuel tanker explosions and storage of combustible material beneath highway structures have led to severe structural damage and catastrophic collapse of prestressed concrete bridges. Critical structural collapse due to fire incidents such as I-85 prestressed …

    fau Repository record for INFLUENCE OF WEB THICKNESS AND CONCRETE COVER ON THE FIRE RESISTANCE OF AASHTO TYPE IV PRESTRESSED CONCRETE BRIDGE GIRDERS (opens in a new tab)