  1. Fire Performance of Hybrid Timber Connections

    … in this construction system particularly under fire exposure. Analysis of hybrid timber connections is complicated because the behavior and properties of the different materials are different under fire exposure.This study aims at investigating the effect of different parameters on the fire …

    carleton Repository record for Fire Performance of Hybrid Timber Connections (opens in a new tab)

  2. Fire Performance of Cold-Formed Steel Walls

    Fire is an important hazard to be considered in structural design. Therefore, rapid growth in the building industry demands lightweight construction to satisfy standardized design criteria that include fire resistance. As envisioned, performance-based fire design involves the development of models …

    jhu Repository record for Fire Performance of Cold-Formed Steel Walls (opens in a new tab)

  3. Fire performance of cold-formed steel sections

    … challenges due to the lack of knowledge to the fire performance of CFS at elevated temperatures and the lack of fire design guidelines. Among all available design specifications of CFS, EN1993-1-2 is the only one which provided design guidelines for CFS at elevated temperatures, which, however, …

    plymouth Repository record for Fire performance of cold-formed steel sections (opens in a new tab)

  4. Post-earthquake fire performance of building structures

    The potential of fire event after a strong earthquake is quite high and the damage caused by this fire could be significantly higher as compared to normal fire not accompanied by an earthquake. Thus it is important to know the behavior of structures under such circumstances. Modern buildings are …

    concordia Download PDF for Post-earthquake fire performance of building structures (opens in a new tab)

  5. Fire performance of frp-strengthened concrete flexural members

    … in capacity and stiffness resulting in lower fire resistance than an un-strengthened concrete member. The fire response of FRP-strengthened concrete structural members is influenced by several factors, and thus fire resistance evaluation requires advanced analysis. While several studies are …

    msu Repository record for Fire performance of frp-strengthened concrete flexural members (opens in a new tab)

  6. Modelling the Fire Performance of Hybrid Steel-Timber Connections

    … concealed, exposed and seated connections. The fire resistance of these connections is evaluated using a finite element model and compared with the full-scale experimental fire resistance tests which had been conducted earlier in a separate project. The finite element model results were in good …

    carleton Repository record for Modelling the Fire Performance of Hybrid Steel-Timber Connections (opens in a new tab)

  7. On the Fire Performance of Exterior Wall Materials and Assemblies

    … into the envelope, contributes to the overall performance of the exterior wall in meeting energy efficiency and hygrothermal requirements. Nowadays, multi-layered exterior envelopes are taking centre stage in construction, gradually replacing conventional monolithic concrete and masonry …

    waterloo Repository record for On the Fire Performance of Exterior Wall Materials and Assemblies (opens in a new tab)

  8. The Analysis of Thermal and Fire Performance of Cementitious Building Components

    … behaviour of reinforced concrete members in fire conditions. The numerical analyses of temperature histories and mechanical behaviour of reinforced concrete structural members subjected to fire are the major components of this research. In this thesis a non-linear finite element procedure is …

    cent-lancashire Repository record for The Analysis of Thermal and Fire Performance of Cementitious Building Components (opens in a new tab) Download PDF for The Analysis of Thermal and Fire Performance of Cementitious Building Components (opens in a new tab)

  9. Fire Performance of Ultra-High Performance Concrete Double-Wythe Insulated Panels

    Ultra-High Performance Concrete (UHPC) is emerging as an alternative material to conventional normal strength concrete in structural applications including bridges, buildings, and structural strengthening and retrofitting. Adoption of UHPC is limited by its relatively poor performance in fire …

    queens Repository record for Fire Performance of Ultra-High Performance Concrete Double-Wythe Insulated Panels (opens in a new tab)

  10. Fires in Narrow Construction Cavities : Fire Dynamics and Material Fire Performance

    There have recently been devastating fire incidents related to fire spread over ventilated façades. These incidents indicate gaps in our understanding of the fire behaviour of façades. This thesis takes a bottom-up approach to investigating fire behaviour in materials and elements associated with …

    lund Repository record for Fires in Narrow Construction Cavities : Fire Dynamics and Material Fire Performance (opens in a new tab) Download PDF for Fires in Narrow Construction Cavities : Fire Dynamics and Material Fire Performance (opens in a new tab)

  11. Peanut Shell-based Flame Retardant and its Fire Performance in Epoxy Resin

    … from peanut shells (CPS), to enhance EP's fire-resistant properties. Additionally, a Fire Dynamics Simulator (FDS) model coupled with kinetic parameters, was applied to analyse the fire behaviour of EP incorporating this flame retardant. The experimental work began by exploring CPS as a …

    unsw Repository record for Peanut Shell-based Flame Retardant and its Fire Performance in Epoxy Resin (opens in a new tab)

  12. Fire performance assessment of concrete with fly ash as the supplemental cementitious material

    … temperatures are imperative to structural fire safety assessment. However, fire performance of concrete at high temperature is extremely complex since concrete is a heterogeneous material with considerable variations. When it is subjected to thermal exposure, such as fire, concrete …

    plymouth Repository record for Fire performance assessment of concrete with fly ash as the supplemental cementitious material (opens in a new tab)

  13. Fire performance of concealed wood-steel-wood connections with perpendicular to grain reinforcement

    This study aimed to investigate the fire behaviour of concealed connections by considering the effects of parameters such as the number of bolts, bolt pattern and load ratios. The connections used for this study were fire-protected glulam beam-to-column reinforced concealed connections loaded …

    carleton Repository record for Fire performance of concealed wood-steel-wood connections with perpendicular to grain reinforcement (opens in a new tab)

  14. Fire Performance of FRP: Bond of GFRP Bars to Concrete and FRP Strengthened Columns

    … reinforced members is recommended to enhance fire resistance. Also, a series of approximate and simple numerical models including heat and structural analysis were developed to study the effects of high temperatures on two FRP-wrapped and insulated reinforced concrete columns tested by the …

    queens Repository record for Fire Performance of FRP: Bond of GFRP Bars to Concrete and FRP Strengthened Columns (opens in a new tab)

  15. A framework for fire performance assessment of mass timber structures : numerical and machine-learning approaches

    This thesis advances the evaluation of fire performance in mass-timber structures, from individual components to a complete building system, through the development of novel numerical modelling approaches and the integration of machine-learning techniques. Firstly, timber compartment fire scenarios …

    ubc Repository record for A framework for fire performance assessment of mass timber structures : numerical and machine-learning approaches (opens in a new tab) Download PDF for A framework for fire performance assessment of mass timber structures : numerical and machine-learning approaches (opens in a new tab)

  16. Analysis of Fire Performance, Smoke Development and Combustion Gases from Flame Retarded Rigid Polyurethane Foams

    … its use over the years. This raises significant fire safety concerns since polyurethanes are inherently very flammable and prone to release toxic gases as the foam thermally decomposes and burns. To improve fire safety characteristics by reducing ignitability and flammability of the foams, …

    waterloo Repository record for Analysis of Fire Performance, Smoke Development and Combustion Gases from Flame Retarded Rigid Polyurethane Foams (opens in a new tab)

  17. Experimental and Numerical Explorations of Fire Performance of Intumescent Thermoplastic Composites for Electric Vehicle Battery Enclosures

    … energy density and efficiency, their inherent fire risk remains a critical safety concern. To mitigate this hazard, plastic-intensive, flame-retardant enclosures have been engineered as promising alternatives to traditional metal-intensive systems for EV battery pack protection. This …

    vt Repository record for Experimental and Numerical Explorations of Fire Performance of Intumescent Thermoplastic Composites for Electric Vehicle Battery Enclosures (opens in a new tab)

  18. A Methodology for Determining the Fire Performance Equivalency Amongst Similar Materials During a Full-scale Fire Scenario Based on Bench-scale Testing

    … amongst materials during a full-scale fire scenario. This procedure utilizes milligram-scale and or bench-scale tests to obtain the effective physical and chemical properties of individual materials through an optimization procedure. A flame heat feedback model was developed for …

    maryland Repository record for A Methodology for Determining the Fire Performance Equivalency Amongst Similar Materials During a Full-scale Fire Scenario Based on Bench-scale Testing (opens in a new tab)

  19. Prediction of fire behaviour for amine cured epoxy resin systems based on molecular structure

    … composites in the transport sector, has made fire performance of composite materials a crucial factor. Due to their organic content, they release volatiles which burn, and also produce toxic fumes which are fatal in high concentrations during pyrolysis. Current approaches to fire retardancy …

    bristol Repository record for Prediction of fire behaviour for amine cured epoxy resin systems based on molecular structure (opens in a new tab) Download PDF for Prediction of fire behaviour for amine cured epoxy resin systems based on molecular structure (opens in a new tab)

  20. A Methodology for Flammability Diagrams

    The current state of fire safety regulations in the United States Department of Transportation is examined, along with some of the associated flammability test methods. The applicability and overall usefulness of these tests is evaluated along with their ability to accurately capture and describe …

    maryland Repository record for A Methodology for Flammability Diagrams (opens in a new tab)