Showing 1 to 20 of 35 for “"fire safety design"”.
-
Fire safety design of road tunnels
… be described as a journey in performance-based fire safety design. Along the way questions such as what fire safety is, how it can be measured, whether we are posing the right questions, or engineer the best solutions, have arisen. The safety journey naturally started out with the traditional …
-
Fire safety design of composite slim floor structures
A structural fire safety design method for composite steel-concrete slim floor structures was developed, including the characterization of fully-developed compartment fire curves and the equivalent fire exposure, temperature analysis of the composite structures, and the structural response analysis …
-
Automated Compliance Audit Processes for Building Information Models with an application to performance-based fire engineering design methods
Every architectural and building engineering design in the AEC/FM (Architectural, Engineering, Construction, and Facility Management) domain is subject to conformance with a diverse range of statutory requirements and standards before the official consent for construction may be granted by the …
-
Pyrolysis and Cracking of Nordic Timbers Under External Heat Exposure
… inherently associated with an increased risk to fire safety. To address the fire risks of wood construction, regulators impose prescriptive building codes that define the limits for use of timber in construction. Performance-based fire safety design is the only method to realize timber …
-
Model Uncertainty in Fire Safety Engineering
Summary: Traditionally, fire safety has often been addressed with methods based on prescriptive recommendations. The opportunity to use an alternative analytical approach has led to the development of fire safety engineering, beginning with structural fire safety design in the 1960's and today …
-
Uncertainty and Risk Analysis in Fire Safety Engineering
… occupants in, for example, a building in which a fire has broken out. The extended QRA considers the inherent uncertainty in the variables explicitly. The standard QRA does not consider the uncertainties in the variables and must be complemented by a sensitivity analysis or an uncertainty …
-
Heat transfer analysis of components of construction exposed to fire
… studyof components of construction exposed to fire.Within the computational aspects of the work, one and two-dimensional finitedifference and finite element methods have been developed to determine thetransient temperature distributions in the cross-section of elements of constructionsubject to …
-
Behaviour of Fibre Reinforced Polymer Confined Reinforced Concrete Columns Under Fire Condition
… requirements. However, concerns associated with fire remain an obstacle to applications of FRP materials in buildings and parking garages due to FRP’s sensitivity to high temperatures as compared with other structural materials and to limited knowledge on their thermal and mechanical behaviour in …
-
Behaviour and reliability of wood tension members exposed to elevated temperatures
The merit of approaching fire safety design from the standpoint of reliability is the impetus of this thesis. Reliability, a direct function of time to failure, is a measure of performance which falls naturally under a performance-based code. The objectives of this study focus on advancing our …
-
Creep buckling behavior of steel columns subjected to fire
The essence of performance-based structural fire safety design of steel building structures is the ability to predict thermal and structural response to fire. An important aspect of such predictions is the ability to evaluate strength of columns at elevated temperatures. Columns are critical …
-
Vibration performance of modular prefabricated cross-laminated timber–steel composite floors
… lateral load-resistance systems, seismic and fire safety design. In the flooring segment, cross-laminated timber (CLT) and CLT-concrete composite floor systems are seeing increased application, while other timber-based composites such as timber-steel and timber-timber composites are not as …
-
Evacuation Modelling of Mixed-Ability Populations in Fire Emergencies
… that a significant percentage of fatalities in fires have suffered from some kind of disability. In this context 'disability' relates to a person's physical or mental condition that impinges on their ability to react and move promptly in an emergency. Various evacuation modelling techniques are …
-
Externally Venting Flames (EVF) dynamics and development in non-orthogonal geometries
… has highlighted the need to address the evolving fire safety challenges associated with modern and sustainable buildings. Particularly in high-rise buildings exterior fire spread and heat transfer caused by Externally Venting Flames (EVF) pose significant challenges as evidenced by the increased …
-
Evaluation of steel columns under fire: Real-time hybrid testing and reliability assessment
The current practice for fire design of structures follows prescriptive approaches based on furnace tests of structural elements. The element-level furnace tests do not capture structural system response and the reliability of fire safety design following current approaches has not been quantified. …
-
A framework for characterizing the safety of Li-BESS using performance based code analysis and testing
… Li-BESS adoption is being hindered by safety concerns related to fire and explosion hazards involving these systems. In the event of thermal runaway, these systems can release flammable gases which can cause fires or explosions. The fire and explosion hazard associated with these cells …
-
Development and assessment of experimetnal and numerical tools for characterization of externally venting flames and evaluation of their effect on building facades
… experimental and theoretical investigation of fire spreading in buildings and façade systems due to Externally Venting Flames (EVF). When a building fire is fully developed, flames may spill out of external openings; it is well established that EVF may significantly increase the risk of fire …
-
Response of long-span and high-strength steel beams to nonuniform temperature fields induced by fire
… members using the finite element (FE) method and fire simulations using computational fluid dynamics were conducted. Comprehensive steady and transient state tensile tests at elevated temperatures were carried out to determine the mechanical properties of S700 MC grade HSS, which were used to …
-
Steel fracture modeling at elevated temperature for structural-fire engineering analysis
… the key elements of performance-based structural-fire safety design is the ability to accurately predict thermal and structural response to fire. For steel structures, significant advances have been made in using finite element models for predicting the response of members, connections and entire …
-
A structured, systemic methodology to improve maritime fire safety in machinery spaces
The primary cause of machinery space fires is cited as the release of flammable oil mist contacting unprotected hot surfaces. With this being common knowledge why do we continue to see this type of incident reoccurring on ships carrying thousands of passengers to precarious destinations? Anecdotal …
-
Utilisation of statistics to assess fire risks in buildings
… data, a general view of the anatomy of fires is established and valuable information relating to fire risks and quantitative methods for the risk-assessment of buildings presented. This work is a step forward in the field of risk-analysis-based fire safety design and overall a step …
Page 1 of 2