Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 122 for “"fire tests"”.

  1. Fire tests on concrete

    Thesis (B.S.)--Michigan Agricultural College, 1913

    msu Repository record for Fire tests on concrete (opens in a new tab)

  2. Numerical modeling of full scale limited ventilation fire tests

    Underventilated enclosure fires represent one of the largest causes of fire fatalities and understanding their behavior is of great interest. The newest major release of the Fire Dynamics Simulator (FDS) has made significant progress towards providing a tool for accurate modeling of underventilated …

    maryland Repository record for Numerical modeling of full scale limited ventilation fire tests (opens in a new tab)

  3. Development of Hybrid Fire Simulation Methods and Their Applications to Column Fire Tests

    The design philosophy in structural fire design has been shifting from prescriptive design toward performance-based design. The hybrid fire simulation method, where a physical element and a numerical model are integrated, can be used to combine the benefits of the element-level fire test and …

    toronto-retro Repository record for Development of Hybrid Fire Simulation Methods and Their Applications to Column Fire Tests (opens in a new tab)

  4. Deriving Generalized Temperature-Dependent Material Models for Masonry Through Fire Tests and Machine Learning

    … masonry provides low-cost construction, fire, and weather protection as well as thermal and sound insulation. In addition, masonry has superior material properties at elevated temperatures which is reflected by its slow degradation of its mechanical and thermal properties. Literature …

    clemson Repository record for Deriving Generalized Temperature-Dependent Material Models for Masonry Through Fire Tests and Machine Learning (opens in a new tab)

  5. Numerical field model simulation of full scale fire tests in a closed and an open compartment

    … study is to adapt a general numerical model of fires within an enclosure to a specific experimental test facility. The test facility is operated at the Naval Air Warfare Center China Lake, California. The research facility is in the process of studying missile fuel fires in a surface ship …

    nps Repository record for Numerical field model simulation of full scale fire tests in a closed and an open compartment (opens in a new tab)

  6. Numerical field model simulation of full-scale fire tests in a closed spherical/cylindrical vessel with internal ventilation.

    Shipboard fires have plagued mariners for centuries; they still cause significant damage and casualties each year. Improved fire prevention and control require a sound knowledge of the phenomena of fire. At the same time, a study of fires in enclosed pressure vessels has been undertaken by the Navy …

    nps Repository record for Numerical field model simulation of full-scale fire tests in a closed spherical/cylindrical vessel with internal ventilation. (opens in a new tab)

  7. On the Potential Use of Small Scale Fire Tests for Screening Steiner Tunnel Results for Spray Foam Insulation

    … is to assess the potential of using bench-scale fire testing to screen materials for the Steiner tunnel fire test. It is hypothesized that the chemical and physical changes made to a material to improve its fire performance in small scale fire tests will have a predictable response in the Steiner …

    waterloo Repository record for On the Potential Use of Small Scale Fire Tests for Screening Steiner Tunnel Results for Spray Foam Insulation (opens in a new tab)

  8. EXPERIMENTAL CHARACTERIZATION AND MODELING OF FLAME HEAT FEEDBACK AND OXIDATIVE PYROLYSIS FOR SIMULATION OF BENCH SCALE FIRE TESTS

    Two important bench scale fire tests, the cone calorimeter test and UL-94V, werecharacterized experimentally to allow for predictions using a numerical pyrolysis solver, ThermaKin2Ds with pyrolysis parameter sets. Flame heat feedback was measured in cone calorimeter tests for several polymers to …

    maryland Repository record for EXPERIMENTAL CHARACTERIZATION AND MODELING OF FLAME HEAT FEEDBACK AND OXIDATIVE PYROLYSIS FOR SIMULATION OF BENCH SCALE FIRE TESTS (opens in a new tab)

  9. Vibration measurements on the Phalanx electro-optical stabilization system

    … (FLIR) camera stabilizer system during live-fire tests to evaluate its performance. Uniaxial, triaxial, and angular accelerometers were mounted at 19 different locations on the stabilizer and on the camera. Acceleration data were collected during eight live fire tests conducted at a Navy …

    nps Repository record for Vibration measurements on the Phalanx electro-optical stabilization system (opens in a new tab)

  10. A multi-scale approach for predicting the fire response of building barriers

    … elements in buildings that limit the passage of fire and smoke to adjacent spaces. They are key elements in the overall response of a building in a fire. The adequate fire response of building barriers is usually assessed by the fulfilment of standardized resistance to fire tests. However, …

    lund Repository record for A multi-scale approach for predicting the fire response of building barriers (opens in a new tab) Download PDF for A multi-scale approach for predicting the fire response of building barriers (opens in a new tab)

  11. Simulation of steel/concrete composite structures in fire.

    … and composite framed buildings subjected to fire. The steel skeleton is represented using two-noded line elements, the steel-to-steel connections using spring elements and the flooring system by isotropic flat shell elements. Structures are therefore considered as a complete entity, allowing …

    whiterose Download PDF for Simulation of steel/concrete composite structures in fire. (opens in a new tab)

  12. The structural response of industrial portal frame structures in fire.

    A number of recent fires in single-storey warehouses have drawn attention to a current lack of understanding about the structural response of industrial portal frame structures to elevated temperatures. This research project has investigated the subject by conducting fire tests on a scaled model …

    whiterose Download PDF for The structural response of industrial portal frame structures in fire. (opens in a new tab)

  13. Fire Performance of Ultra-High Performance Concrete Double-Wythe Insulated Panels

    … is limited by its relatively poor performance in fire conditions, a result of its propensity for explosive spalling. Additionally, a lack of formal fire standards and ratings adopted by national building codes for the use of UHPC in structural applications is a deterrent to its adoption. In an …

    queens Repository record for Fire Performance of Ultra-High Performance Concrete Double-Wythe Insulated Panels (opens in a new tab)

  14. Accelerating the Flame Retardant Design: From Small-scale to Bench-scale

    … nanofillers in polymeric nanocomposites. The fire tests were then scaled up to the bench scale and addressed the flame retardancy with a cone calorimeter. Finally, an accelerated design of flame-retardant polymeric nanocomposites via a machine learning prediction model was performed to …

    tamu Repository record for Accelerating the Flame Retardant Design: From Small-scale to Bench-scale (opens in a new tab)

  15. Fire protection of surface coatings

    Multilayer paint is a significant fire hazard particularly concerning rapid spread of flame,smoke and toxic species production. Fire protective coatings are often employed to protect this unpredictably flammable substrate from ignition (for example resulting from arson attacks in the communal areas …

    cent-lancashire Download file for Fire protection of surface coatings (opens in a new tab)

  16. Performance of Load-Bearing Cold-Formed Steel Wall Systems with Web-Perforated Studs Subjected to Standard Fire

    … with CFS C-shape studs with one or two layers of fire-rated sheathing attached to both sides. In practice, perforations are placed in stud webs to accommodate the passage of utilities or installation of intermediate braces. These walls may fail by local buckling at the web perforations, combined …

    waterloo Repository record for Performance of Load-Bearing Cold-Formed Steel Wall Systems with Web-Perforated Studs Subjected to Standard Fire (opens in a new tab)

  17. Development and implementation of a methodology for hybrid fire testing applied to concrete structures with elastic boundary conditions

    Fire tests remain a precious tool to comprehend the behavior of structures under accidental fire conditions. The common practice in fire testing is to isolate the tested element in a furnace in which the mechanical support conditions are maintained constant throughout the test. However, such tests …

    liege Repository record for Development and implementation of a methodology for hybrid fire testing applied to concrete structures with elastic boundary conditions (opens in a new tab) Download PDF for Development and implementation of a methodology for hybrid fire testing applied to concrete structures with elastic boundary conditions (opens in a new tab)

Page 1 of 7