Showing 1 to 20 of 34 for “"five-story"”.
-
Post occupancy evaluation of five story walk up dwellings : the case of four mass housing estates in Algiers.
Because of the acute shortage of housing in Algeria, resulting from a high birth rate and the migration of the rural population to the cities, large mass housing programmes have been launched since the late 1970s, providing the urban population with dwellings and housing facilities just outside the …
-
Determination of the Modal Parameters of a Five Story Reinforced Concrete Structure Using Ultra-Low Level Excitation and Computational Analysis
… Polytechnic State University San Luis Obispo, a five-story reinforced concrete shear wall structure. The specific testing procedure used has been verified to produce accurate results in smaller buildings, but the Kennedy Library represents the most massive subject structure. Other characteristics …
-
Camden Plaza: a mixed-use megastructure
A twenty-five story, 200,000 square foot mixed-use complex on the edge of Baltimore's downtown office district. A building system reminiscent of the Japanese Metabolists' is developed, but with less of a preoccupation with "high-tech" imagery. This system is manipulated to produce plazas and public …
-
Pemberton Mills 1852-1938: a case study of the industrial and labor history of Lawrence, Massachusetts
On January 10, 1860, the five-story Pemberton Mill in Lawrence, Massachusetts, collapsed, burying more than six hundred Irish and native-born textile workers in a vast pile of debris. The event had many consequences. It affected numerous practices in the textile industry. It brought the Pemberton …
-
Performance-based seismic analysis and design improvements of two precast concrete structural systems
… various intensities. The maximum transient interstory drift, residual interstory drift and floor acceleration are considered as acceptance criteria for evaluating seismic performance of these systems subjected by four levels of ground motions. Interstory drift and floor acceleration are directly …
-
A Beachfront High-rise
… and resident services on the ground floor, a five-story parking garage, and a rooftop pool, restaurant, and sun deck.
-
Reducing Residual Drift in Buckling-Restrained Braced Frames by Using Gravity Columns as Part of a Dual System
… two, a heavy elastic brace in the top story, and three, a heavy elastic brace in the middle bay. Single and multiple degree of freedom models were analyzed to determine if gravity columns can be effective in reducing residual drift. In the single degree of freedom system (SDOF) models, …
-
Statistical structural health monitoring: Methodologies and Applications
… damaged reinforced concrete (RC) frame, a five-story shear frame, a shear wall, a twenty-degree-of-freedom system and a hyperbolic paraboloid roof shell as well as the experimental example of the I-40 Bridge benchmark.
-
Third
… the project disguises itself as a normative five-story building containing spaces for domestic, professional, and social activities. The result is a limited palette of planimetric and three-dimensional representations that stage mundane scenes of habitation and routine as something unfamiliar …
-
Design, construction, and analysis of a modular structural model for shake tables
… to that gap by designing and evaluating a five-story, 2-by-1 bay structure with replaceable columns and adjustable floors. The model was developed to support studies involving structural parameter variations and numerical model validation. To assess its consistency across physical and …
-
Policy Evaluation and Recommendation for Preserving Residential Compounds in Beijing: A Process-Oriented Approach
… and usually consisted of groupings of three to five-story buildings with various amenities and institutions. The construction of these neighborhoods profoundly shaped the city’s landscape. Since the reform of the "work-unit" system and the opening of the housing market in the late 1990s, …
-
"The Wrong Building, in the Wrong Place, at the Wrong Time": Marcel Breuer and the Grand Central Tower Controversy, 1967-1969
… by Marcel Breuer and Associates to float a fifty-five-story office tower in the air rights above Grand Central Terminal. As a flashpoint in the development of US preservation policy, the dispute over Breuer’s addition has figured prominently in historical accounts of the postwar city. This study, …
-
Connection and structural level analysis of precast hybrid frame systems
… was then used to examine the response of a five-story precast hybrid building model under different earthquake loading. From the response of the building, it has been shown that the hybrid building will perform satisfactorily under earthquakes of different intensities. An investigation on a …
-
Adapting the Built for the Buried: Biomimicry for Groundwater Recharge in Urban Infrastructure
… up to 5 million gallons per year from a single five-story building. These findings suggest that when contextually scaled, biomimetic interventions can make a quantifiable contribution toward mitigating urban groundwater deficits. The thesis ultimately reframes the built environment as a …
-
Development and experimental validation of self-centering buckling-restrained braces with shape memory alloy
… is both in tension and compression. Using a five-story building as context, half-scale SC-BRBs are designed and fabricated for experimental validation. To characterize hysteretic response, the braces are subjected to a cyclic loading protocol adapted from the AISC Seismic Provisions for …
-
New Housing in Tenleytown
… Despite Tenleytown's strong character and history, there are surprising gaps in its development. Specifically, across from the crossroads of River Road and Wisconsin Avenue there is a large block zoned for an allowable building height of 90' and an FAR of 4.5. Currently there are thirteen one …
-
Seismic fragility and retrofitting for a reinforced concrete flat-slab structure
… enhance seismic performance was assessed for a five-story reinforced concrete (RC) flat-slab building structure in the central United States. In addition to this, an assessment of seismic fragility that relates the probability of exceeding a performance level to the earthquake intensity was …
-
Seismic design and demand assessment of isolated and innovative timber lateral load resisting systems
… at a case study building, using an Inter-Story Isolation (ISI) configuration. As result of this study, the optimal stories of installation of the isolation layers are identified and the decrease in response with increasing the number of isolation layers is quantitatively assessed. Then, a …
-
An Effective Model for Dynamic Properties of Local Soils and Their Influence on Seismic Response of a Typical Reinforced Concrete Building
… central Adapazarı, Turkey, where four- to seven-story buildings suffered significant damage during the 1999 Kocaeli earthquake. A new model is presented that combines small-strain field data and large-strain laboratory data to produce the local soil profile's dynamic properties for site-response …
-
Random decrement based method for parameter identification of wind-excited building models using acceleration responses
… forces. The experimental simulation employs a five-story aeroelastic building model tested in a wind tunnel. These simulations are particularly critical to manifest the characteristics of the random decrement acceleration signatures when using the random decrement based method. The …
Page 1 of 2