Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"fixation failure"”.
-
Frakturbehandlung langer Röhrenknochen bei Hund und Katze mit einem 2.0/2.4mm Fixateur interne System : die ersten konsekutiven 66 Frakturen
… Komplikationen wurden erfasst und in Fixationsversagen und andere Komplikationen eingeteilt. Der Einfluss verschiedener Parameter auf das Auftreten von Komplikationen wurde statistisch ausgewertet. Resultate: 66 Frakturen wurden behandelt. Das UniLock System wurde bei 44 Frakturen zur …
-
Comparative Evaluation of TFNA versus PFNA in the Treatment of Intertrochanteric Fractures in Elderly Patients: A Clinical Efficacy Analysis
… fragility and functional limita-tions, surgical fixation is typically required. TFN-ADVANCED™ (TFNA) and proximal femoral nail anti-rotation (PFNA) are two widely used implants for ITF treatment. How-ever, their comparative efficacy remains unclear. Since TFNA replaced PFNA in our institution in …
-
Early range of motion exercise in pediatric patients with olecranon fractures treated with tension band suture with double loops and double knots
… of the tension band suture technique and enhance fixation tensile strength. We believe that early range-of-motion exercises could be achieved without nonunion or fixation failure. Methods: Twelve pediatric patients with olecranon fractures were treated with tension band suture with double loops …
-
Finite element analysis of a cementless proximal femoral stem in relation to early stem stability and interface bone strain
… of the femur, which suggest that risk of fixation failure and implant migration increase with decrease of overall bone stiffness. This suggests that more predictive preclinical finite element analyses of new stem designs should be performed with multiple femurs, which span the range of the …
-
Optimisation Of Fixation Methods For Vancouver Type B2 And B3 Periprosthetic Femoral Fracture Treatment
… poor bone stock (Type B3 fractures). Clinical failures and unclear optimal treatment recommendations for many fractures suggest that further investigation is required. This study mechanically tested experimental specimens representing the cemented long stem revision treatment of a Type B2 PFF …
-
The Advanced Locking Plate System (ALPS): application and results in 71 small animal patients
… in a radius/ulna fracture in a cat; (2) fixation failure occurred in a femoral fracture in a cat with all monocortical fixations of the proximal fragment being pulled out of the bone; (3) a radius/ulna fracture in a dog needed revision surgery because of non-healing and implants getting …
-
Epidemiology and outcome of fractures in elderly and super-elderly patients
… of 162 elderly patients that underwent internal fixation for an undisplaced intracapsular hip fracture was collected. An established database of proximal humeral fractures was used to describe epidemiology and outcome of these fractures in the elderly. Two hundred and twenty-eight displaced …
-
Complications following surgery for hip fracture
… 365-day risk of prosthesis dislocation was 1.1%, fixation failure 1.8%, and peri-prosthetic or peri-implant fracture 2.2%; and the 30-day risks of re-operation for any indication was 2.3% and surgical site infection (SSI) 1.7%. For general complications, the 30-day risk of acute kidney injury was …
-
Minimally invasive treatment approaches in the operative management of unstable ankle fractures
… treatment approaches, including intramedullary fixation of the fibula and treating well-reduced medial malleolar fractures non-operatively, following fibular stabilisation. This thesis aims to examine both concepts further through a series of retrospective, biomechanical and randomised …
-
Nonunion of the clavicle: novel use of clinical recovery and ultrasound to improve our ability to predict fracture healing
… widespread increase in the use of acute plate fixation for displaced fractures is justified on current evidence. It is unknown whether the early accurate prediction of fractures at high risk of nonunion is advantageous. Currently the perceived risk of nonunion is largely based on factors …
-
Biomechanical investigation of the factors related to pedicle screw fixation strength
… intervention is often performed using internal fixation devices. Fixation with pedicle screws is a well-established method providing spinal stability and deformity correction. However, reported rates of fixation failure because of screw loosening have become a major concern, especially with the …
-
Λοξή διαφυσιακή οστεοτομία 1ου μεταταρσίου (Ludloff) για την διόρθωση βλαισού μεγάλου δακτύλου: συγκριτική εμβιομηχανική μελέτη δύο τύπων
… in 1918, the osteotomy was performed without any fixation. In the mid-1900s, Myerson et al. re-introduced the procedure, using two interfragmental compression screws for fixation. Problematic issues associated with use of the Ludloff osteotomy, similar to other proximal and shaft osteotomies, …