Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 123 for “"flame ionization detector"”.

  1. Calibration of flame ionization detector for chlorinated hydrocarbons

    … for chlorine substituted compounds on FI detector at standard conditions. This is in contrast with previous investigators studies which employed older detector designs. Recent engineering improvement (1970 to present) in FI detector design and geometry with optimized combustion, flow …

    njit Repository record for Calibration of flame ionization detector for chlorinated hydrocarbons (opens in a new tab)

  2. A Hairpin Resonator Based Flame Ionization Detector for Gas Chromatographs

    A novel hydrocarbon-sensitive detector was investigated to determine if readily achievable sensitivity compares with that of the contemporary flame ionization detector. The targeted application is for use in a gas chromatograph system as a complement to less discriminatory detectors. A series of …

    houston Repository record for A Hairpin Resonator Based Flame Ionization Detector for Gas Chromatographs (opens in a new tab)

  3. Development and experimental analysis of a micro-flame ionization detector for portable gas chromatographs

    … has been developed that utilized a diffusion flame encased in a micro-fabricated SOI structure. The micro-flame was fueled by a portable electrolyzer that provided the hydrogen and oxygen flow rates necessary for the device operation. The micro-FID was able to detect organic analytes with …

    uiuc Repository record for Development and experimental analysis of a micro-flame ionization detector for portable gas chromatographs (opens in a new tab)

  4. Characteristics of a Novel Alkali Flame Ionization Detector as an Air Sensor for Volatile Organonitrogen Compounds

    … and characterization of a novel alkali flame ionization detector (AFID) for use as an air sensor for organonitrogen compounds without any chromatographic separation. Using a planar channelled quartz design, a simple, lightweight architecture for the portable device is presented, which …

    calgary Repository record for Characteristics of a Novel Alkali Flame Ionization Detector as an Air Sensor for Volatile Organonitrogen Compounds (opens in a new tab)

  5. The application of gas-liquid chromatography to the structural investigation of Polysaccharides

    … by gas-liquid chromatography, using the hydrogen-flame ionization detector. The conditions used compared favourably with conditions reported by other workers and were well suited to the quantitative analysis of methanolysis products from methylated polysaccharides. Excellent separations were …

    cape-town Repository record for The application of gas-liquid chromatography to the structural investigation of Polysaccharides (opens in a new tab)

  6. Measurement of Low Vapor Pressures: A Kinetic Approach

    … in a tube. The air stream was combusted, and a flame ionization detector was used to measure the mass of CO2 so obtained. Several different flow rates were used at each temperature with each substance.

    portland-state Repository record for Measurement of Low Vapor Pressures: A Kinetic Approach (opens in a new tab)

  7. Thermal desorption of hazardous and toxic organic compounds from soil matrices

    … (nitrogen) and a gas chromatogragh equipped with Flame Ionization Detector but no added column other than the soil was used to measure the axial dispersion and the rate of passage of the organic contaminants through various soil matrices. The soil matrices used were Gas Chrom R, organic soil, and …

    njit Repository record for Thermal desorption of hazardous and toxic organic compounds from soil matrices (opens in a new tab)

  8. Effect of inorganic salts on adsorption process

    … of organic pollutants was measured using a Flame Ionization Detector Gas Chromatograph. This study investigated the role of inorganic salts during the sorption process. The results of this study show the improvement of treatment efficiency by the addition of inorganic salts depends on the …

    njit Repository record for Effect of inorganic salts on adsorption process (opens in a new tab)

  9. An explosive vapor generator based on capillary gas chromatography

    … The design of the vapor generator replaces a flame ionization detector on the gas chromatograph with an effluent heater system to provide a cloud of explosive vapor while preventing condensation onto the walls of the capillary column. This vapor source has been successfully used to produce …

    vt Repository record for An explosive vapor generator based on capillary gas chromatography (opens in a new tab)

  10. Catalytic oxidation of chlorinated hydrocarbons over powdered transition metal oxide

    … Gas chromatography with electron capture detector and flame ionization detector was used for quantitative analysis of feed and product streams. Gas chromatography/mass spectrometry and gas chromatography/Fourier transform infrared spectroscopy were used to identify all oxidation products. …

    njit Repository record for Catalytic oxidation of chlorinated hydrocarbons over powdered transition metal oxide (opens in a new tab)

  11. Sorption and desorption of organic compounds by flyash

    … separately. The samples were analyzed using a Flame Ionization Detector Gas Chromatograph. The result of this study demonstrates that isolation/ immobilization of the organic pollutants is technologically feasible by adsorbing the contaminants onto flyash. The residual carbon content of the …

    njit Repository record for Sorption and desorption of organic compounds by flyash (opens in a new tab)

  12. A Kinetic Analysis on Hydrolysis and Hydrothermal Conversion of Cellulose to Dodecane

    … for identification and Gas Chromatography Flame Ionization Detector for quantification. Our findings revealed the formation of a possible dodecane isomer, a known fuel additive. We also examined the role of hydrogen content in conversion and proposed a probable reaction mechanism. Kinetic …

    etsu Repository record for A Kinetic Analysis on Hydrolysis and Hydrothermal Conversion of Cellulose to Dodecane (opens in a new tab) Download PDF for A Kinetic Analysis on Hydrolysis and Hydrothermal Conversion of Cellulose to Dodecane (opens in a new tab)

  13. Characterization of Planar Titanium Platforms for Flame Ionization Detection in Microfluidic Gas Chromatography

    Gas chromatography (GC) with a Flame Ionization Detector (FID) has been widely used for the analysis of volatile organic compounds in various fields. Instrument portability and miniaturization of the FID for micro GC (μGC) applications are of increasing interest. This thesis describes the design …

    calgary Repository record for Characterization of Planar Titanium Platforms for Flame Ionization Detection in Microfluidic Gas Chromatography (opens in a new tab)

  14. The terpenes of Virginia pine (<u>Pinus virginiana mill</u>.), with investigations of their attractancy to the southern pine beetle (<u>Dendroctonus frontalis</u> zimm.)

    A gas chromatograph, equipped with a flame ionization detector, was used to qualitatively and quantitatively analyze the monoterpenes of Virginia pine. The instrument was adjusted for optimum performance prior to sample analysis. Two packed columns with stationary phases of different polarity, …

    vt Repository record for The terpenes of Virginia pine (<u>Pinus virginiana mill</u>.), with investigations of their attractancy to the southern pine beetle (<u>Dendroctonus frontalis</u> zimm.) (opens in a new tab)

  15. The Design of Gas Chromatography Ionisation Detectors:A Study of the Electron Capture Detector and the Home Ionisation Detector

    Two gas ionization detectors were studied from an instrument designer's point of view. Experimental results indicate that the electron capture detector is sensitive to carrier gas density and to atmospheric oxygen. The finite conductivity of electrode insulators was also found to play an important …

    aston Download PDF for The Design of Gas Chromatography Ionisation Detectors:A Study of the Electron Capture Detector and the Home Ionisation Detector (opens in a new tab)

  16. Adsorption and kinetics of adsorption by flyash in solution

    … examined and the samples were analyzed using a Flame Ionization Detector Gas Chromatograph. The potentialities of adsorption on flyash as a method of renovation of water have not been realized fully, because little knowledge is available regarding the effective application of the method for this …

    njit Repository record for Adsorption and kinetics of adsorption by flyash in solution (opens in a new tab)

  17. An improved method of gas chromatographic determination of trace organic vapors in ambient air collected in canisters

    … The column effluent is measured by a parallel flame ionization detector (FID), and electron capture detector (ECD). The problems associating with quantitative transfer of the sample to the initial cryofocusing loop and with injection of the sample to the capillary column (2nd cryofocusing step) …

    njit Repository record for An improved method of gas chromatographic determination of trace organic vapors in ambient air collected in canisters (opens in a new tab)

  18. Development of a Novel Alcoholic Spirit From the New Zealand Native Plant Cordyline australis

    … spectrometry (SPME-GC-MS) and gas chromatography flame ionization detector (GC-FID) compared with four commercial spirit products to show similarities and differences. A distinctive spirit was produced with similarities to tequila.

    auckland-tech Repository record for Development of a Novel Alcoholic Spirit From the New Zealand Native Plant Cordyline australis (opens in a new tab)

  19. Development of a micro-FID using a diffusion flame

    A micro-flame ionization detector (micro-FID) was developed operating with a diffusion flame with a folded flame structure. Unlike conventional FIDs, an air-hydrogen diffusion flame was developed and tested in an encapsulated structure of Quartz-Macor®-Quartz layers. Diffusion flames are generally …

    uiuc Repository record for Development of a micro-FID using a diffusion flame (opens in a new tab)

  20. Zebra GC: A Fully Integrated Micro Gas Chromatography System

    … column with on-chip thermal conductivity detector (microSC-TCD), the flow controller unit, and all the necessary flow and thermal management as well as user interface circuitry are integrated to realize the fully functional microGC system. The work reports extensive characterization of …

    vt Repository record for Zebra GC: A Fully Integrated Micro Gas Chromatography System (opens in a new tab)

Page 1 of 7