Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 41 for “"flame ionization detector (FID)"”
-
Characterization of Planar Titanium Platforms for Flame Ionization Detection in Microfluidic Gas Chromatography
Gas chromatography (GC) with a Flame Ionization Detector (FID) has been widely used for the analysis of volatile organic compounds in various fields. Instrument portability and miniaturization of the FID for micro GC (μGC) applications are of increasing interest. This thesis describes the design …
-
An improved method of gas chromatographic determination of trace organic vapors in ambient air collected in canisters
… The column effluent is measured by a parallel flame ionization detector (FID), and electron capture detector (ECD). The problems associating with quantitative transfer of the sample to the initial cryofocusing loop and with injection of the sample to the capillary column (2nd cryofocusing step) …
-
Thermal desorption of organic contaminant from sand using a continuous feed rotary kiln
… by a Gas Chromatograph (GC) equipped with a flame ionization detector (FID).</p><p>Each investigation was done at different temperatures, and, from these experiments an engineering equation was developed where the resistance time needed for removal can be predicted for any given temperature …
-
Measurement and Fractionation of Diesel Exhaust Hydrocarbons through Variable Temperature Controlled-Condensation and Flame Ionization Detection
… measuring hydrocarbons in engine exhaust is the flame ionization detector (FID). FID can measure total hydrocarbon concentrations but is limited in that it is not equally sensitive to all hydrocarbons present in exhaust. Instruments capable of measuring individual gas species such as gas …
-
Recovery, separation and characterization of phenolic compounds and flavonoids from maple products
… standards were developed using a wide range of detectors, including ultraviolet diode-array (UV-DAD) and electrochemical (EC) detectors for HPLC and flame ionization detector (FID) and mass spectrometry (MS) for GC. The results demonstrated that the limits of detection obtained with HPLC-EC …
-
Development of a fast methane sensor based on wavelength modulation spectroscopy for exhaust methane emission measurement
… using gas standards and validated against a flame ionization detector (FID). The 508 mm heated gas cell reliably detects CH₄ from 50 ppm to over 2% at a temporal resolution of over 200 Hz. The WMS sensor can resolve transient methane emission with a time delay and time constant of 0.55 s and …
-
Um Método Espectrofotométrico para Quantificação de Furfural em Cachaças por Extração Líquido-Líquido
… method based on gas chromatography with flame ionization detector (FID) (GC-FID), no statistical difference between the results was observed. The LLE method was sensitive, accurate and precise with recoveries in the range 102-109%, linear range of 0,2 to 8 mg 100 ml-1, limits of detection …
-
Sol-gel Resorcinarene Sorbent for Capillary Microextraction Coupled to Gas Chromatography
… limits (0.828 – 46.01 ng/L) in GC using a Flame Ionization Detector (FID). CME was performed by passing the aqueous samples through the resorcinarene coated microextraction capillary (10 cm). The extracted analytes where then thermally desorbed into the GC column connected to the exit end …
-
Desenvolvimento e validação de um método para determinação de colesterol em farinha de carne e ossos em mistura de alimentos para ruminantes utilizando cromatografia gasosa.
… of polyetileneglycol 30mx0,25mmx0,25µm and flame ionization detector (FID). GC conditions were: injection 1 µL, insert 260 ºC, column 100 ºC/2min and 260 ºC/48min (15 ºC/min), flow 1,68 mL/min, drag gas hydrogen and FID 300 ºC. Cholesterol was identified by comparison of retention times of …
-
Thermal desorption of hazardous and toxic organic compounds from soil matrices
… measured by a gas chromatograph equipped with a flame ionization detector (FID). The process was mathematically modeled and can be used to predict behavior such as effusion rates and transport of these compounds in soil desorption systems.</p><p>Second, a desorption system was constructed which …
-
Analysis and Treatment of Emerging Polar Contaminants
… system, hyphenated to a universal gas phase detector, flame ionization detector (FID), was designed. By using pure subcritical water as a mobile phase, temperature was used to control chromatographic retention. This instrument may be used for rapid screening of environmental samples with …
-
Estudio analítico de compuestos volátiles en vino: caracterización quimiométrica de distintas denominaciones de origen
… mode coupled with gas-chromatography (CG) and a flame ionization detector (FID) is selected as a rapid method for the analysis of volatile compounds from wine samples . The optimised method was successfully applied to the analysis of wine samples from five Denomination of Origin ( Rioja, Navarra, …
-
A comparative study of VPO catalysts in the oxidation of butane to maleic anhydride.
… (GC) monitoring system. A thermal conductivity detector (TCD) was employed for carbon oxide monitoring and a flame ionization detector (FID) for all other products. The catalysts were characterised by X-ray diffraction (XRD) to determine the phases present in the precursor, calcined and used …
-
Advancements in selenium speciation, fast gas analysis and sample preparation procedures for the chemical analysis of real-world samples.
The Pulsed Discharge Helium Ionization Detector (PDHID) was compared to the Flame Ionization Detector (FID) and the Thermal Conductivity Detector (TCD) for High Speed Gas Chromatography (HSGC). It was shown that the PDHID is as sensitive as the FID but can be less reproducible. Moreover, the PDHID …
-
Otimização de condições cromatográficas para quantificação de teor de ativo de Acefato por cromatografia gasosa com detector por ionização em chama (FID)
… of acephate by gas chromatography coupled to the flame ionization detector (FID), with a lower cost alternative when compared to techniques coupled to mass spectrometry. To optimize the chromatographic parameters, the acephate samples were prepared at concentrations of 100% active, 4 and 10 g L-1, …
-
Exploring Novel Strategies for Universal Detection in Chromatography
… included the further development of a universal detector that is compatible with organic solvents, as well as exploring separation techniques that are compatible with the universal Flame Ionization Detector (FID). For instance, the universal response of the Acoustic Flame Detector (AFD) was …
-
Development of a portable instrumentation system for "In Situ" assessment of soil respiration
… tested using a gas chromatograph equipped with a Flame Ionization Detector (FID) and an Electron Capture Detector (ECD). A dedicated software application in both MATLAB® and Python™ was developed to process the raw data from the device and extract the relevant defining parameters. The RSCA was …
-
Polytetrahydrofuran-and Dendrimer-Based Novel Sol-Gel Coatings for Capillary Microextraction (CME) Providing Parts Per Trillion (ppt) and Parts Per Quadrillion (ppq) Level Detection Limits in Conjunction With Gas Chromatography and Flame Ionization Detection (FID)
… with gas chromatography (GC). Using a Flame ionization detector (FID), low parts per trillion (ppt) and parts per quadrillion (ppq) level detection limits were achieved in CME-GC for both polar and nonpolar analytes including polycyclic aromatic hydrocarbons (PAHs), aldehydes, ketones, …
-
Thermal desorption of hazardous and toxic organic compounds
… with a gas chromatograph (GC) equipped with a flame ionization detector (FID). A relationship was developed based on time and temperature requirements for complete desorption of the selected pollutant species with inert gas purge. This relationship was used to develop an engineering equation …
-
Denitrogenation of Thermally Cracked Naphtha
… with gas chromatography coupled with both flame ionization detector (FID) and nitrogen phosphorus detector (NPD). Measurements of NPD response to different classes of nitrogen compounds were performed, thus the results have revealed that the response would be structure dependent. A …
Page 1 of 3