Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 28 for “"flat panel detector"”
-
Investigation of an amorphous silicon flat-panel detector for ion radiography
… X-ray imaging; however, it lacks simple detectors suitable for this purpose. In this study the performance of an amorphous silicon flat-panel detector, originally designed for photon imaging, was investigated for radiographic and tomographic imaging with ions. After the application of a …
-
Development of a Flat Panel Detector with Avalanche Gain for Interventional Radiology
… using a very low x-ray exposure (~ 1 uR at the detector). At such an exposure, most semiconductor-based digital flat panel detectors (FPD) are not x-ray quantum noise limited (QNL) due to the presence of electronic noise which substantially degrades their imaging performance. The goal of this …
-
Rare Earth-Doped Glass-Ceramic Scintillators as X-Ray Flat Panel Detector Substrates
… x-rays to form a digital image. DR employs a flat panel detector that converts incident x-rays, that have passed through the subject, to an electrical signal, which is used to create a digital image. The conversion from x-rays to electrical signals can be done either directly or indirectly. …
-
IMPROVING REALTIME 3-D TRACKING OF HIGH DOSE RATE RADIATION SOURCE USING A FLAT PANEL DETECTOR
… between our C program and the new Varex Paxscan flat panel detector (FPD). Finally, we will try to embed our C codes into a MATLAB graphical user interface (GUI) This research will attempt to improve the overall existing system in several ways including, code optimization and trying a sample …
-
REAL TIME 3-D TRACKING OF THE HIGH DOSE RATE RADIATION SOURCE USING A FLAT PANEL DETECTOR
A number of QA procedures have been developed for Breast Brachytherapy treatments, yet none guarantee accurate dose delivery or allow conformation of the actual source position leading to errors sometimes going unnoticed. The objective of this study is to track the exact path the HDR source would …
-
Dual Energy X-ray for Quantitative Analysis of areal Bone Mineral Density (aBMD) using a stacked Flat Panel Detector (FPD)
This study explores the application of a stacked flat panel detector (FPD) system for spectral dual-energy X-ray imaging aimed at quantifying areal bone mineral density (aBMD). The proposed technique enables single-exposure dual-energy acquisition using a conventional cone-beam X-ray source, …
-
Retrospectively Gated Computed Tomography in Mice
… using a volumetric micro-CT scanner with a flat-panel detector mounted on a slip ring gantry. An acrylic edge phantom mimicking cardiac motion was used to characterize the system’s resolution. My findings were also demonstrated in a mouse model. Results: Measurements of resolution …
-
Desenvolvimento de um sistema de microtomografia de raios X de baixo custo para amostras de pequenas dimensões e baixas densidades
… dimensions and low densities is presented. A flat panel detector originally developed for dental applications was used. The characterization process that allowed its implementation in a microtomographic system is detailed in the work. A study of the linear and volumetric magnifications of the …
-
Spatial Resolution Analysis of a Variable Resolution X-ray Cone-beam Computed Tomography System
… CT (VRX-CBCT) uses a CsI-based amorphous silicon flat panel detector (FPD) that can tilt about its horizontal (u) axis and vertical (v) axis independently. The detector angulation improves the spatial resolution of the CT images by changing the effective size of each detector cell. Two components …
-
Development and Realization of the IGRT Inline Concept
… realization is described. An x-ray tube and a flat panel detector were installed along the treatment beam axis, such that the detector could not only be used for x-ray imaging of patients lying on the treatment couch, but also to measure the primary fluence of the therapy beam. The imaging …
-
Development of a motion-free tomographic imaging system
… without any moving parts. With a clinical flat-panel detector, we demonstrate 3D reconstructions of several biological samples.
-
New Methods for Motion Management During Radiation Therapy
… simulation for an improved amorphous-silicon flat-panel detector that reduced treatment beam filtration by 60% and long-range MV-scatter by 80%. We conclude this thesis by presenting results of an experimental demonstration of a novel dose-saving actively-triggered 4d cone-beam computed …
-
Modeling of resolution of x-ray imaging detectors
A flat-panel detector based on a photoconductive detector with an active matrix array provides superior x-ray images. Amorphous selenium (a-Se) is currently the best choice of photoconductor for clinical x-ray image detectors. Spatial resolution in terms of modulation transfer function (MTF) is an …
-
Dose Optimization in Cardiovascular Interventional Radiology
… it has been measured the energy response of a flat panel detector (Varian CB4030) and, with a dedicated phantom and a software simulation, the image contrast of vessels injected with Iodine and CO2. The results show that the contrast generated by carbon dioxide is about one fourth of that …
-
Multilayer Energy Discriminating Detector for Medical X-ray Imaging Applications
… remove the contrast of normal tissue. Large area flat panel detectors may be used for CEM wherein the subtraction of two acquired images is used to create the resulting enhanced image. There exist several methods to acquire the images to be subtracted, which include temporal subtraction (pre- and …
-
Fabrication and Integration of CMUT Sensors
… could be the ultrasound-equivalent of x-ray flat panel detector arrays and could help to replace operator intervention in ultrasound scanning with automated electronic scanning.
-
Source strength verification and quality assurance of sterile, pre-loaded iodine-125 seed trains used for prostate brachytehrapy
… implant needles. The system used consisted of a flat panel image detector, an autoclavable apparatus (“jig”) to hold the needles in a fixed geometry relative to the detector, and software to analyze the detected signals. In addition to defining the geometry of the detection system, the jig serves …
-
Development of X-ray Coherent Scatter Projection Imaging Systems
… motorized stages for object translation, a flat-panel x-ray detector for measuring scattered x rays, and discrete photodiodes for simultaneously measuring transmitted x rays. The acquisition time for a 5.0 cm × 9.0 cm object with 8425 pixels was 2.3 min. Use of continuous motion acquisition …
-
X-RAY DOSE DEPENDENCE OF DARK CURRENT IN AMORPHOUS SELENIUM-ALLOY X-RAY PHOTOCONDUCTORS
… characteristic of a photoconductive X-ray detector, and can impact the dynamic range of the detector and its detective quantum efficiency. It is therefore essential that the dark current and its behavior with time and x-ray irradiation are well characterized and understood in amorphous …
-
Development of High-performance Flexible Poly-Si Thin Film Transistors and GaAs PIN Photodiode for Advanced X-ray Imaging
… industrial inspections. However, the existing flat panel detectors fail to meet the challenges posed by large-area and curved surface imaging. They are also inadequate for low radiation dose and high spatial resolution applications such as digital breast tomosynthesis (DBT) and fluoroscopy. In …
Page 1 of 2