Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 50 for “"flattening filter"”
-
Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode
… by using a higher dose rate, provided by flattening filter free (FFF) photon mode. To validate that increasing dose rate through removal of the flattening filter does not decrease cell kill, radiobiological experiments were carried out with three cell lines. Both the clonogenic survival …
-
Dosimetric effects of removing the flattening filter in radiotherapy treatment units
… the dosimetric effects of removing the flattening filter from conventional C-arm medical linear accelerators. In conventional linear accelerators used for radiotherapy, a flattening filter is positioned in the beam line to provide a uniform lateral dose profile at a specified depth in …
-
Improved Target Coverage of Spinal Metastases Through The Use of Flattening Filter Free Beams
… local control and tumor recurrence at follow-up. Flattening Filter Free (FFF) photon beams have been shown to have lower out-of-field dose and sharper dose gradients when compared with conventionally flattened (FF) photon beams of similar energy; this sharp dose fall-off could potentially prove …
-
Flattening Filter Free photon beams for treatment of early-stage lung cancer: an investigation of peripheral dose
… SABR treatments for 10X, 6X, and 10X-FFF beams. Flattening Filter Free (FFF) radiotherapy photon beams exhibit high dose rates as compared to standard flattened photon beams. The high dose rates available with FFF beams make them ideal for high dose treatments, such as Volumetric Modulated Arc …
-
Determination of the Shape of a Flattening Filter Free (FFF) Radiation Beam When Modified by a Physical Wedge
The determination of a flattening filter free (FFF) beam profile when the collimator is intentionally modified to incorporate a physical wedge. Specifically, radiation beam profiles change shape when a metallic wedge is placed in the path of the beam. Examination of this unknown is necessary to …
-
Developing a QA procedure for gated VMAT SABR treatments using 10 MV beam in flattening-filter free mode
… Arc Therapy (VMAT) using a 10 MV beam in Flattening Filter Free (FFF) mode. This method takes advantage of the high dose gradient region of SABR treatments to detect any inaccuracies in the performance of the Varian Real-time Position Manage- ment (RPM) gating system. This study involves …
-
Potential Efficacy of the Monte Carlo Dose Calculations of 6MV Flattening Filter-Free Photon Beam of M6™ Cyberknife® System
MapCheck measurements for 50 retrospective patient’s treatment plans suggested that MapCheck could be effectively employed in routine patient specific quality assurance in M6 Cyberknife with beams delivered at different treatment angles. However, these measurements also suggested that for highly …
-
Monte Carlo modelling of peripheral dose and risk of secondary malignancy in flattening-filter-free and 10 MV photon beams for paediatric radiotherapy
… radiotherapy treatment modes: 6MV flattened, 6MV flattening-filter-free (FFF) and 10MV FFF. To establish the clinical significance of the dose difference between the three modes, the risk of SMN as calculated by four different risk models was assessed for whole lung irradiation (WLI). The mixed …
-
Evaluation of The Effectiveness of Anisotropic Analytical Algorithm In Flattened and Flattening-Filter-Free Beams For High Energy Lung Dose Delivery Using The Radiological Physics Center Lung Phantom
… lung phantom using both flattened and flattening-filter-free high energy beams. Radiation treatment plans were developed following the Radiation Therapy Oncology Group and theRadiologicalPhysicsCenterguidelines for lung treatment using Stereotactic Radiation Body Therapy. The tumor was …
-
A Dosimetric Evaluation of The Eclipse and Pinnacle Treatment Planning Systems in Treatment of Vertebral Bodies Using IMRT and VMAT with Modeled and Commissioned Flattening Filter Free (FFF) Fields.
Modern treatment planning systems (TPS's) utilize different algorithms in computing dose within the patient medium. The algorithms rely on properly modeled clinical setups in order to perform optimally. Aside from various parameters of the beam, modifiers, such as multileaf collimators (MLC's), …
-
Ακριβής προσδιορισμός παραμέτρων ποιότητας δέσμης ακτινοβολίας στην ακτινοθεραπεία με τη βοήθεια επαναληπτικών υπολογιστικών μεθόδων monte carlo
… of the photon beam due to the present of the flattening filter. These calculations were made along the central ray and at 10, 17, and 24 cm off axis rays. The analysis of the results showed that as the distance from the central axis increases from 0 to 24 cm the mean energy of the 6 MV beam …
-
Unflattened Radiotherapy beams; characterisation, optimisation and application
The goal of this thesis was to investigate flattening filter free (FFF) beams produced by medical linear accelerators for radiotherapy applications, from their initial setup through to their clinical implementation. This was split into four sections that comprise the main experimental chapters of …
-
Absorbed dose in the build-up region in modern megavoltage photon radiotherapy
… to 6.2x20 cm². Secondly, we focussed on flattening filter-free linear accelerators, which currently face swift implementation into clinical practice because of their increased dose rate and reduction in head scatter compared to conventional designs. Our study demonstrated that build-up …
-
Μελέτη της βελτιστοποίησης εξελιγμένων τεχνικών ακτινοθεραπείας με χρήση νανοσωματιδίων
… increase. For this purpose, a flattened and a flattening filter free 6 ΜV photon beam arising from the TrueBeam® linear accelerator was modelled in GATE platform. AuNPs of different sizes were arranged in clusters and distributed in different depths in a modelled water phantom. The clusters …
-
Implementation of TG-351 Reference Dosimetry for a 6 MV Photon Beam in an MR-Guided Radiotherapy System
… used to perform reference dosimetry for a 6 MV flattening filter-free (FFF) photon beam from a Viewray MRIdian MR-Linac radiation therapy system. Beam quality determination, magnetic field correction factors, and radial profile corrections for FFF beams are included in the calculation for …
-
COMMISSIONING AND ACCEPTANCE TESTING OF A TRUEBEAM LINEAR ACCELERATOR
… with 4 megavoltage (MV) energies of which 2 are flattening filter-free (FFF) and 6 electron energies varying from 6 MeV to 20 MeV. A 2 dimensional (2D) water tank was used for scanning all the required field sizes for all the energies. The one dimensional (1D) water tank was used to collect all …
-
Quality Assurance Procedures Implementation for Varian TrueBeam
… LINAC includes 6x, 6xFFF (i.e., 6x without flattening filter known as flattening filter free), 10x, 10xFFF, 15x photon beams and 6e, 9e, 12e MeV electron beams. This system is also equipped with a 6 degree of freedom (DOF) couch, RapidArc, kV on board imager, MV portal imager and Cone Beam …
-
The 8-channel dynamic channel equalizer and its adaptation as a "smart amplifier solution"
… Doped Fiber Amplifier) design without GFF (Gain Flattening Filter) and its integration with the DCE and embedded control electronics into a Smart Amplifier is proposed. Further improvement of the Smart Amplifier is suggested. The systems design approach, where all subsystems are taken into …
Page 1 of 3