Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"flex sensors"”.

  1. Evaluating Appropriateness of Emg and Flex Sensors for Classifying Hand Gestures

    … of the integrated sensor system are: Surface EMG sensors, Flex sensors and accelerometers. Surface EMG is the electrical activity produced by muscle contractions and measured by sensors directly attached to the skin. Bend Sensors use a piezo resistive material to detect the bend. The sensor output …

    unt Repository record for Evaluating Appropriateness of Emg and Flex Sensors for Classifying Hand Gestures (opens in a new tab)

  2. Wearable flex sensors at the human-computer interface: Investigating security applications and privacy threats

    … and threats. First, with the plethora of sensors inbuilt into these devices, it might be possible to extract user-specific signatures (both physical and behavioral) to augment the traditional authentication schemes already in place. Such a user-derived security layer would mitigate many of …

    ttu Repository record for Wearable flex sensors at the human-computer interface: Investigating security applications and privacy threats (opens in a new tab) Embargoed until 2026-12-01

  3. Evaluating the Feasibility of Accelerometers in Hand Gestures Recognition

    … SWAT team gestures using different types of sensors. Accelerometer and flex sensors were explored extensively to build a prototype for soldiers to communicate in the absence of line of sight. Arm movements were recognized by flex sensors and motion gestures by Accelerometers. Accelerometers …

    unt Repository record for Evaluating the Feasibility of Accelerometers in Hand Gestures Recognition (opens in a new tab)

  4. Modelling of a segmented pneumatic soft actuator with integrated sensors using neural networks

    … segmented PneuNet actuator with two integrated flex sensors. Data was then gathered from this actuator which was used for training several neural networks to predict the three joint angles of the actuator. The results of this project can not definitively state the feasibility of using neural …

    chalmers Repository record for Modelling of a segmented pneumatic soft actuator with integrated sensors using neural networks (opens in a new tab)

  5. Smart Glove and Hand Gesture-Based Control Interface for Multi-Rotor Aerial Vehicles

    … A motion-processing unit (MPU) and a set of four flex sensors are used in the smart glove to produce discrete and continuous signals based on the bending value of each finger and the roll angle of the left hand. The generated discrete signals with the flex sensors are fed to a support vector …

    concordia Download PDF for Smart Glove and Hand Gesture-Based Control Interface for Multi-Rotor Aerial Vehicles (opens in a new tab)

  6. Creating a responsive, real-time, malleable environment for dancers

    … is by no means trivial. From piezo and flex sensors, radio frequency transceivers and bluetooth radios, to the ultimate development of a novel sensor system (the VDancer) that can eliminate the need for wires and breakable flex sensors, this thesis details the search for a system that is …

    iastate Repository record for Creating a responsive, real-time, malleable environment for dancers (opens in a new tab)

  7. ARTHE: AN AUGMENTED REALITY-ASSISTED THREE-STAGE HEALTHCARE EXERCISING SYSTEM

    … VIEW OF THE USER?S CONDITIONS, FIVE FLEX SENSORS, FIVE FORCE SENSORS AND TWO ACCELEROMETERS ARE INSTALLED ON AN AR-BASED DATA GLOVE TO MEASURE THE BENDING DEGREES OF THE FINGERS, GRIP FORCE AND ACCELERATION OF THE ARM SIMULTANEOUSLY. IN ADDITION, TWO LOW-COST RESIDENTIAL-BASED …

    nus Repository record for ARTHE: AN AUGMENTED REALITY-ASSISTED THREE-STAGE HEALTHCARE EXERCISING SYSTEM (opens in a new tab) Download file for ARTHE: AN AUGMENTED REALITY-ASSISTED THREE-STAGE HEALTHCARE EXERCISING SYSTEM (opens in a new tab)

  8. Unmanned systems: a lab-based robotic arm for grasping

    … and proved ineffective. Experiments with flex sensors on the glove for normal hand movements were completed and were successful.

    nps Repository record for Unmanned systems: a lab-based robotic arm for grasping (opens in a new tab)

  9. Exploration Of Robotics Need In The Medical Field And Robotic Arm Operation Via Glove Control

    … a robotic arm. The glove consists of multiple flex sensors and an inertial measurement unit (IMU) that sends data to an Arduino, which processes the data and sends a signal through Bluetooth transmission to the robotic arm. The robotic arm consists of servo motors that move according to the …

    bucknell Repository record for Exploration Of Robotics Need In The Medical Field And Robotic Arm Operation Via Glove Control (opens in a new tab)

  10. Mirror Rehabilitation Therapy with Mirrored Glove

    … sensor evaluation process—including flex sensors, linear and rotational potentiometers, photoresistors, fiber optic emitter-receiver pairs, and Hall effect sensors—the linear potentiometer was selected for its optimal balance of accuracy, cost, and reliability. The motorized glove …

    unt Repository record for Mirror Rehabilitation Therapy with Mirrored Glove (opens in a new tab)

  11. Toward Untethered Autonomous Real-World Deployment of Mobile Soft Robots: from Standardized Fabrication to Closed-Loop Control and Proprioceptive Sensing

    Soft robots, constructed from compliant and flexible materials, offer inherent adaptability, versatile motion, and safe interaction with both the environment and humans. These compelling characteristics have also spurred the development of diverse actuation strategies including fluidic, …

    alabama Repository record for Toward Untethered Autonomous Real-World Deployment of Mobile Soft Robots: from Standardized Fabrication to Closed-Loop Control and Proprioceptive Sensing (opens in a new tab)

  12. Sistema multissensorial vestível de baixo custo para captura de marcha humana aplicado a exoesqueleto ortopédico Ortholeg 2.0

    … proposed system composed of four encoder type sensors, five inertial measurement unit sensors and four flex sensors, allowing to measure the kinematic parameters of the anthropomorphic movements.

    brazil-ufrn Repository record for Sistema multissensorial vestível de baixo custo para captura de marcha humana aplicado a exoesqueleto ortopédico Ortholeg 2.0 (opens in a new tab)

  13. Development of Wearable Sensors for Body Joint Angle Measurement

    … for body joint angle measurement using wearable sensors. Continuous monitoring of patients' movements and activities has recently become one of the active research areas in the field of body sensor network and telehealth monitoring. For many medical and rehabilitation applications, a continuous …

    denver Repository record for Development of Wearable Sensors for Body Joint Angle Measurement (opens in a new tab)

  14. Development of an Instrumented Mannequin for Training of Caregivers in Safe Patient Handling and Movement

    … was achieved by retrofitting a mannequin with flex sensors, electrogoniometers, pressure sensors, and photocells. The sensors were capable of quantifying angular displacement, skin pressure distribution and undignified exposure. All of these variables were monitored by a computer-based data …

    usf Repository record for Development of an Instrumented Mannequin for Training of Caregivers in Safe Patient Handling and Movement (opens in a new tab)

  15. Real-Time Control of Bilateral Movement Training System for Stroke Patients

    … upper limb. The system employs a range of sensors, namely flex sensors, Inertial Measurement Units (IMUs), and Electromyography (EMG) sensors, to achieve precise position and force control. We validated the functionality of the system on healthy individuals by performing tests that included …

    tamu Repository record for Real-Time Control of Bilateral Movement Training System for Stroke Patients (opens in a new tab) Embargoed until 2027-08-01

  16. Real-Time Control of Bilateral Movement Training System for Stroke Patients

    … upper limb. The system employs a range of sensors, namely flex sensors, Inertial Measurement Units (IMUs), and Electromyography (EMG) sensors, to achieve precise position and force control. We validated the functionality of the system on healthy individuals by performing tests that included …

    tamu Repository record for Real-Time Control of Bilateral Movement Training System for Stroke Patients (opens in a new tab) Embargoed until 2027-08-01

  17. Real-Time Control of Bilateral Movement Training System for Stroke Patients

    … upper limb. The system employs a range of sensors, namely flex sensors, Inertial Measurement Units (IMUs), and Electromyography (EMG) sensors, to achieve precise position and force control. We validated the functionality of the system on healthy individuals by performing tests that included …

    tamu Repository record for Real-Time Control of Bilateral Movement Training System for Stroke Patients (opens in a new tab) Embargoed until 2027-08-01

  18. Real-Time Control of Bilateral Movement Training System for Stroke Patients

    … upper limb. The system employs a range of sensors, namely flex sensors, Inertial Measurement Units (IMUs), and Electromyography (EMG) sensors, to achieve precise position and force control. We validated the functionality of the system on healthy individuals by performing tests that included …

    tamu Repository record for Real-Time Control of Bilateral Movement Training System for Stroke Patients (opens in a new tab) Embargoed until 2027-08-01

  19. Real-Time Control of Bilateral Movement Training System for Stroke Patients

    … upper limb. The system employs a range of sensors, namely flex sensors, Inertial Measurement Units (IMUs), and Electromyography (EMG) sensors, to achieve precise position and force control. We validated the functionality of the system on healthy individuals by performing tests that included …

    tamu Repository record for Real-Time Control of Bilateral Movement Training System for Stroke Patients (opens in a new tab) Embargoed until 2027-08-01

  20. Real-Time Control of Bilateral Movement Training System for Stroke Patients

    … upper limb. The system employs a range of sensors, namely flex sensors, Inertial Measurement Units (IMUs), and Electromyography (EMG) sensors, to achieve precise position and force control. We validated the functionality of the system on healthy individuals by performing tests that included …

    tamu Repository record for Real-Time Control of Bilateral Movement Training System for Stroke Patients (opens in a new tab) Embargoed until 2027-08-01

Page 1 of 2