Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 38 for “"floor acceleration"”.
-
Effect of Torsional Ground Motion Component on Floor Acceleration Response in Flexible SMRF Buildings
… components of the ground motions (TGM) on the floor acceleration response of flexible special moment resisting frame (SMRF) buildings. For this purpose, computational models of three SMRF buildings were subjected to far-field ground motions with and without TGMs. Accordingly, the effect of TGM …
-
Assessment of seismic floor acceleration demands on nonstructural components in limited ductility RC frame buildings designed according to NBC 2015
… on quantifying the seismic demands on the acceleration-sensitive nonstructural components (NSCs) attached to the RC moment-resisting frame buildings with limited ductility and designed according to the National Building Code of Canada (NBC 2015). A total of four benchmark structures with …
-
Assessment of Floor Accelerations in Yielding Buildings
… analysis method is employed to evaluate the floor response of inelastic steel moment frame buildings subjected to all three components of a suite of 21 ground motions. To better understand the acceleration demands on nonstructural components, this study focuses on the influence of structural …
-
Performance-based seismic analysis and design improvements of two precast concrete structural systems
… interstory drift, residual interstory drift and floor acceleration are considered as acceptance criteria for evaluating seismic performance of these systems subjected by four levels of ground motions. Interstory drift and floor acceleration are directly related to structural and non-structural …
-
Seismic Analysis and Design for Enhanced Performance of Nonstructural Components in Steel Buildings
… better quantify the seismic demands imposed on acceleration-sensitive components mounted in steel buildings with common lateral force resisting systems, including Special Concentrically Braced Frame (SCBF) and Special Moment Frame (SMF) structures. The second main objective focuses on developing …
-
Base Isolation of a Chilean Masonry House: A Comparative Study
… this study is to reduce the interstory drifts, floor accelerations, and shear forces experienced by masonry houses subject to seismic excitation. Ambient vibration testing was performed on a case study structure in Maip�, Chile, to identify characteristics of the system. Upon creating a multiple …
-
Design of self-centering rocking steel braced frames : an engineering demand trade-off approach considering enhanced performance
… demands, such as inter-story drift ratio and floor acceleration, together with the goal of producing designs that reduce the total damage in the building system, including structural and nonstructural damage. This dissertation presents the modeling, design, and analysis of three- and …
-
Seismic performance, design and placement of multiple tuned mass dampers in building applications
… the vibration modes and installed at various floors of a building structure so that the floor acceleration can be significantly reduced and the potential damage to non-structural components in the building can be minimized. A practical yet reasonably accurate procedure for optimal placement of …
-
Seismic performance and fragility assessment of ductile light non-structural components in nonlinear structures: from peak demand factors to loss estimation
… These results indicate 40–60% reductions in peak floor acceleration, velocity, and displacement demands when NSC ductility increases from μ = 1.0 to μ ≈ 2.0 under resonant conditions. In the second step, Incremental Dynamic Analysis (IDA) is employed to quantify the combined effects of structural …
-
Seismic Design Optimization of Steel Structures Using Genetic Algorithm
… performance levels in terms of story drift and floor acceleration demand parameters. With the capability to consider an active ground motion subset scheme, the computational effort was significantly reduced without prohibiting soGA to find optimal design solutions that satisfy the performance …
-
Optimal design and assessment of nonlinear inerter vibration absorbers for earthquake response mitigation of building structures
… inerter, a lightweight device resisting relative acceleration through the inertance property, has been heavily considered in the scientific literature to improve the seismic building response mitigation capacity of FVDs and DVAs, giving rise to new promising classes of inerter-based seismic …
-
Seismic Response Analysis of a Full-Scale Base-Isolated Structure via Measurements and Modeling
… from sparse seismic-response measurements of floor accelerations. The method requires only direct matrix calculations (factorizations and multiplications); no iterative trial-and-error methods are required. The method requires a mass matrix, or at least an estimate of the floor masses. A …
-
Assessment of the effect of non-structural walls on the dynamic properties and engineering demand parameters of a case study building
… in terms of inter-story drifts and peak floor accelerations under the effect of selected and scaled earthquake records matching Montreal’s uniform hazard spectrum with a return period of 2500 years. First, ambient vibration measurements (AVMs) were conducted on the bare frame composed of …
-
Comparative response of mid-rise (9-story) based-isolated and conventional steel moment resisting frame buildings
… study (Sayani et al. 2011) with respect to peak floor acceleration, peak story drifts, and peak plastic rotation. A pair of 9-story isolated and conventional buildings were designed by Forell/Elsesser, using the same design philosophy as 3-story buildings that were investigated earlier. Both …
-
Effect of Multi-Component Excitation on the Sliding Response of Unanchored Components in Nuclear Facilities
… method detailed in ASCE 4-16. A suite of 40 floor acceleration histories obtained from response history analysis of a representative nuclear power plant facility are used as input for the sliding model. A wide range of friction coefficients is selected for analysis and the nonlinear sliding …
-
A simplified methodology for seismic design and assessment of nonstructural elements
… engineers. The existing analysis procedures of floor response spectrum method and modal synthesis method are very detailed and cumbersome to be efficiently used in a design office. Expressions recommended by building codes predict a response which, in many cases, is significantly different from …
-
Impact of connection details of architectural components on seismic induced repair cost in a shear wall building
… as inter-story drift ratio and peak horizontal floor acceleration) while using different prediction methods and highlight the correlation between calculated EDPs and their corresponding repair costs. Moreover, the results demonstrated that enhancing connection detailing can reduce repair costs …
-
Experimental and numerical investigation of human-induced vibration performance in mass timber office buildings
Timber floors are susceptible to vibration due to their low mass and bending stiffness. Utilizing mass timber products in long-span scenarios, such as in office buildings, makes vibration an important design driver for structural engineers. The performance of long-span office floors is studied both …
-
Seismic Performance Assessment of Wood-Frame Shear Wall Structures
… characteristics, level of gravity loads, and floor acceleration variations. A subset of building model designs that were originally designed for the development of FEMA P-695 methodology is adapted for the numerical evaluations and a baseline for the variations is established. To study the …
-
Effects of Connections Detailing and Friction Dissipation Devices on the Seismic Response of a Hospital Steel Braced Frame Building
… Rd> 2.0, while the interstorey drift at each floor is limited to 1.0%hs. Herein, Rd is the ductility-related force modification factor and hs is the storey height. Although the non-structural components and the hospital contents are not part of this research, they constitute a larger loss in …
Page 1 of 2