Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"floor diaphragm"”

  1. Inelastic Seismic Response Of Reinforced Concrete Buildings With Floor Diaphragm Openings

    Floor and roof systems are designed to carry gravity loads and transfer these loads to supporting beams, columns or walls. Furthermore, they play a key role in distributing earthquake-induced loads to the lateral load resisting systems by diaphragm action. In reinforced concrete buildings, the …

    wustl Repository record for Inelastic Seismic Response Of Reinforced Concrete Buildings With Floor Diaphragm Openings (opens in a new tab)

  2. System Level Interactions and Floor Diaphragm Out-of-Plane Stiffness Effects on the Lateral Response of Light Frame Wood Shear Walls

    … design approaches. In particular, the impact of floor diaphragm out-of-plane stiffness on the lateral behaviour of wood shear walls, and its role in mitigating cumulative deformations along the height of multi-storey systems, introduces complexities in the interpretation of global response …

    ottawa-retro Repository record for System Level Interactions and Floor Diaphragm Out-of-Plane Stiffness Effects on the Lateral Response of Light Frame Wood Shear Walls (opens in a new tab)

  3. In-plane stiffness of cross-laminated timber floors

    … study investigates the in-plane stiffness of CLT floor diaphragms and addresses the lateral load distribution within buildings containing CLT floors. In practice, it is common to assume the floor diaphragm as either flexible or rigid, and distribute the lateral load according to simple hand …

    ubc Repository record for In-plane stiffness of cross-laminated timber floors (opens in a new tab)

  4. Parametric Study of Self-Centering Concentrically-Braced Frames with Friction-Based Energy Dissipation

    … bearings between the columns at each floor level transfer the inertia forces from the gravity columns (which are connected to the floor diaphragm) to the SC-CBF (which is not directly connected to the floor diaphragm). Friction at the lateral-load bearings increases the overturning …

    ohiolink Repository record for Parametric Study of Self-Centering Concentrically-Braced Frames with Friction-Based Energy Dissipation (opens in a new tab)

  5. RC/COMPOSITE WALL-STEEL FRAME HYBRID BUILDINGS WITH CONNECTIONS AND SYSTEM BEHAVIOR

    … connections; to investigate the influence of floor diaphragms on the performance and stiffness characteristics of such connections; and to develop design criteria for ductile failure modes. To achieve these objectives, a coordinated experimental and analytical study was performed. The research …

    ohiolink Repository record for RC/COMPOSITE WALL-STEEL FRAME HYBRID BUILDINGS WITH CONNECTIONS AND SYSTEM BEHAVIOR (opens in a new tab)

  6. Performance of lightweight floor diaphragms under lateral loads

    Floor structural elements carry permanent and imposed loads applied to the floor to the surrounding beams, columns, or wall panels. Floor system transfers the load under bending type out-of-plane mode of deformation as well as distributes the resultant wind and earthquake actions to the lateral …

    uws Repository record for Performance of lightweight floor diaphragms under lateral loads (opens in a new tab)

  7. Performance of Cross-Laminated Timber Panel-to-Panel Diaphragm Connections with and without Tension Straps

    … the performance of cross-laminated timber floor diaphragm panel-to-panel connections loaded perpendicular to the joint with and without steel tension straps. Spline and half-lap connections are commonly used to join panels in-plane and are designed for loads parallel to the joint. Their …

    carleton Repository record for Performance of Cross-Laminated Timber Panel-to-Panel Diaphragm Connections with and without Tension Straps (opens in a new tab)

  8. Innovative stainless-steel connector for double-tee girders under various loading conditions

    … to join precast elements together to create floor diaphragm systems in structures such as parking garages. These steel connections are the main load transferring elements in precast structures and have been observed to be inadequate needing repairs after being in service due to high load …

    ksu Repository record for Innovative stainless-steel connector for double-tee girders under various loading conditions (opens in a new tab)

  9. Testing of a full-scale mass timber diaphragm

    … has not been fully investigated are horizontal diaphragms for floors, roofs, or bridge decks. This thesis aims to test a single large scale CLT cantilever diaphragm subjected to a simulated seismic load. Data was collected and the behavior of the diaphragm documented to help begin to reduce this …

    colostate Repository record for Testing of a full-scale mass timber diaphragm (opens in a new tab)

  10. Finn Hall Community Spaces Redesign

    … the design of the gravity system with a CLT floor diaphragm, glulam beams, and columns. The project also contains the design of connections of the mass timber redesign and to the existing sections of Finn Hall. Lastly, this project included a comparison of carbon emissions and costs between …

    santa-clara Repository record for Finn Hall Community Spaces Redesign (opens in a new tab)

  11. Evaluation of seismic fragilities of special concentrically braced frame equipped with innovative cross-laminated timber-steel floor diaphragms

    Floor diaphragms are structural elements mainly responsible for transmitting lateral loads to the adjoining vertical members of the Seismic-Force-Resisting System (SFRS). Under significant seismic events, the actual in-plane stiffness of floor diaphragms affects patterns of load distribution …

    ubc Repository record for Evaluation of seismic fragilities of special concentrically braced frame equipped with innovative cross-laminated timber-steel floor diaphragms (opens in a new tab)

  12. Shake table testing of hybrid wood shear wall system

    … with wood studs (but no sheathing) and a CLT floor diaphragm to support a seismic weight of 12,000 lbs. The structure was subjected to the 1989 Loma Prieta ground motion record scaled to different intensities. The final test used the original 1994 Northridge ground motion record from the …

    colostate Repository record for Shake table testing of hybrid wood shear wall system (opens in a new tab)

  13. Seismic performance of post-and-beam wood buildings

    … combination of 2D assemblies (e.g. shear walls, floor/roof diaphragms) while capturing the global structural responses of interest (e.g., inter-story drift and floor/roof acceleration). A mechanics-based wood shear wall model is implemented to represent the hysteretic properties of …

    ubc Repository record for Seismic performance of post-and-beam wood buildings (opens in a new tab)

  14. Parametric Study and Higher Mode Response Quantification of Steel Self-Centering Concentrically-Braced Frames

    … (where lateral load is transferred from the floor diaphragm to the SC-CBF) to dissipate energy and reduce the peak structural response.Previous research has identified that the frame geometry is a key design parameter for SC-CBFs, as frame geometry relates directly to the energy dissipation …

    ohiolink Repository record for Parametric Study and Higher Mode Response Quantification of Steel Self-Centering Concentrically-Braced Frames (opens in a new tab)

  15. Study of Deflection of Single and Multi-Storey Light Frame Wood Shear Walls

    … effects especially when the out-of-plane diaphragm stiffness is considered. The current study aims at investigating the effects of construction details variation on the behavior of the shear walls and evaluating whether the current deflection equation, as per wood design standard (CSA …

    ottawa-retro Repository record for Study of Deflection of Single and Multi-Storey Light Frame Wood Shear Walls (opens in a new tab)

  16. Enhancing Seismic Resiliency of Steel Buildings through Three-Dimensional Modeling of Diaphragm System Interaction with Braced Frame

    … resisting system (HLFRS) consisting of the floor and roof diaphragm. The floor diaphragm acts as a critical element that distributes the demands developed in a building during an extreme event to the vertical lateral-force resisting systems and eventually to the building foundation. Compared …

    jhu Repository record for Enhancing Seismic Resiliency of Steel Buildings through Three-Dimensional Modeling of Diaphragm System Interaction with Braced Frame (opens in a new tab)

  17. Behaviour and Design of Composite Metal Deck Diaphragms Subjected to In-plane Shear Forces

    The primary function of suspended flooring systems in multi-storey buildings is to support gravity loads, and transfer these loads to other structural members, such as beams, walls and columns. Moreover, they play a key role in the distribution of lateral loads into the structural system and …

    auckland-ms Repository record for Behaviour and Design of Composite Metal Deck Diaphragms Subjected to In-plane Shear Forces (opens in a new tab)

  18. The critical role of floor diaphragms in the seismic response of existing and retrofitted reinforced concrete buildings

    bergamo Repository record for The critical role of floor diaphragms in the seismic response of existing and retrofitted reinforced concrete buildings (opens in a new tab)