Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 138 for “"flow cytometer"”.
-
A paraboloidal flow cytometer for improved fluorescence analysis of single cells
<p>A new flow cytometer featuring a paraboloidal flow chamber for optical collection has been designed to improve fluorescence analysis of single cells. The improvement is achieved by increasing the fluorescence collection efficiency, permitting measurement of weakly fluorescent particles, and by …
-
Development of a Diffraction Imaging Flow Cytometer for Study of Biological Cells
… we have designed and built a diffraction imaging flow cytometer with the ability to efficiently acquire high-contrast diffraction images from individual flowing cells. A series of experimental and modeling studies have been carried out to build this instrument including fabrication of square …
-
Evaluation of Stallion Sperm Membrane Integrity Using Varied Flow Cytometer-Based Methodologies
… two fluorescent vital-staining protocols used in flow cytometric analysis were compared – a combination of SNARF-1, Yo-Pro-1, and Ethidium Homodimer 1 (SYE) and a combination of lectin from Pisum sativum and propidium iodide (PSA/PI). We hypothesized that the SYE protocol adapted for use with …
-
Microwave Flow Cytometer for Single Cell Detection, Differentiation, and Drug Effect Study
… increase. The results show that microwave flow cytometry is a promising new method for high throughput and noninvasive characterization of cell heterogeneity. Moreover, broadband microwave measurement is a promising new approach for physicians to provide personalized candidemia therapy. …
-
Flow cytometer optimisation and standardisation for the study of extracellular vesicles as translational biomarkers
… In this thesis, I have developed methods for flow cytometer (FCM) resolution quantification, improvement, and standardisation. This involved building, testing and validating FCM optical models for EV analysis standardisation, and optimising FCM settings and protocols to increase resolution and …
-
Design and Operation of a Microwave Flow Cytometer for Single Cell Detection and Identification
… to penetrate cell membranes, making microwave flow cytometry a promising technology for label-free biosensing. In this dissertation a microwave flow cytometer is designed and used to measure single biological cells and micro particles. A radio frequency (RF)/microwave interferometer serves as …
-
Fluorescence activated sorting of antibody-labeled islets using an EPICS Elite ESP flow cytometer
A Beckman Coulter EPICS Elite ESP Flow Cytometer with a 400 [Mu]m tip was used to attempt to separate pancreatic tissue from acinar cells following digestion of the pancreas with collagenase. The islets were fluorescently labeled by using A2B5 as a primary antibody, and either a FITC or …
-
Investigation of microscale particles using a microfluidic flow cytometer equipped with a sensitive photodetector
<p>We have developed a sensitive optofluidic cytometer to investigate microscale particles. The flow cytometer is comprised of a microchannel that has a set of chevron-shaped grooves. Conducted by the chevrons, two sheath streams focus the core stream in the center of the microchannel …
-
A droplet-based microfluidic impedance flow cytometer for detection and quantification of microplastics in water
… and concentration of microplastics, we created a flow-focusing droplet generator with coplanar electrodes. Polystyrene microbeads of four distinct sizes and three different concentrations were employed. The impedance measurements were taken with a lock-in amplifier at three distinct frequencies: …
-
Development of a Microchip-Based Flow Cytometer with Integrated Optics – Device Design, Fabrication, and Testing
<p>Lab-on-a-chip technologies have created a burgeoning number of new and novel devices designed to automate biological processes on-chip in an efficient and inexpensive format for far reaching point-of-care (POC) medicine and diagnostic treatments and for remote and on-line monitoring functions. …
-
Design, fabrication and characterisation of a low-cost, acoustically focussed imaging flow cytometer for automated analysis of phytoplankton
… can only be provided by light microscopy and flow cytometry, two time-consuming and expensive methods. To address these challenges, this thesis details the development of a novel, high-throughput, acoustically focussed Imaging Flow Cytometer for low-cost imaging of phytoplankton in natural …
-
Development of a microfluidic flow cytometer for plant protoplast analysis and manipulation by means of laser radiation pressure
… involving microfluidic systems, particularly, flow cytometry. The advent of these highly capable microfluidic cytometry systems has brought new opportunities for research which in turn has begun to provide new applications in the industry. In the first chapter we review the current state of …
-
Validation of a comercially available fluorescence-based instrument to evaluate stallion spermatozoal concentration and comparison to photometric systems
… important to equine breeding operations. The hemacytometer is considered the standard for measuring spermatozoal concentration but is time consuming and may be imprecise. The flow cytometer is considered precise and accurate, but only practical for research purposes due to sample preparation time …
-
An Optical System towards In-line Monitoring of Bacteria in Drinking Water
… this goal, such as ELISA, PCR, FISH, FTIR and flow cytometry. However, they still have limitations of non-specificity, complexity and high cost. Therefore, an optical system is proposed and developed towards the in-line monitoring of bacteria, which combines the advantages of FTIR and …
-
Comparison of Methods for Assessing Viability of Equine Spermatozoa and Effects of Seminal Plasma on Viability and Motion Characteristics of Equine Spermatozoa
… for evaluating stallion sperm quality. The flow cytometer is considered the standard in the assessment of sperm plasma membrane integrity (viability); however, this instrument is costly to purchase and use, and it requires an experienced technician to operate it. The growing practice of …
-
An investigation into fuel cells and flow cytometers optimal design
… performance of fuel cells. CFD was used to study flow channels and information learned from the study was used to design a new and improved flow channel. A prototype of the new design was fabricated, tested and found to perform better than conventional designs. Protons mass flow equation and …
-
Optical particle analysis for use in simultaneous high throughput flow cytometry
… dielectrophoresis analysis in a high throughput flow cytometer system. To examine the viability of combining optical and dielectrophoretic analysis methods, this thesis proposes an optical model using Mie scattering theory, and a data extraction and particle classification algorithm that employs …
-
Modular Neural Networks for Analysis of Flow Cytometry Data
… developed an automated optical tool, called a Flow Cytometer (FC), to analyse samples quickly and in large quantities. The flow cytometer has<br/>successfully been applied to real phytoplankton studies. However, analysis of the data extracted from samples is still required. Artificial Neural …
-
Development of smartphone-based flow cytometry for selective cell counting
… capacity for multiplexed imaging. Along with flow cytometry, QDs of various colours allow for the detection and enumeration of multiple cell types simultaneously, which is critical for early and efficient screening for diseases, including cancers. Flow cytometry is widely recognized as the …
-
Investigation of the genotoxic potential of the marine biotoxins okadaic acid and azaspiracids
… and assess the right concentration range. Flow cytometer analysis was included to detect the possible involvement of apoptotic processes. In house background data for all endpoints were established using positive controls. Three different cell lines, Jurkat T cells, CaCo-2 cells and HepG-2 …
Page 1 of 7