Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 190 for “"flow loop"”.
-
Benchmarking of a sCO2 Heat Exchanger Flow Loop
… studied experimentally by commissioning a sCO2 flow loop featuring a horizontal tube-in-tube counterflow heat exchanger with a circular cross section. The main objective was to establish experimental heat transfer research capabilities for sCO2 at Embry-Riddle Aeronautical University’s (ERAU) …
-
Investigating Mitral Valve Disease Progression Using a Flow Loop Bioreactor
… Here I sought to take advantage of an existing flow loop bioreactor capable of intact organ culture of porcine mitral valves, in order to investigate the remodeling response of valve tissues to the altered mechanics of the two main etiologies of mitral regurgitation. My global objective was to …
-
Design and Fabrication of a Vertical Pump Multiphase Flow Loop
… pump has been devised to handle two-phase flow. However, it requires full scale testing to allow further development. Testing is required to verify performance and to gain information needed to apply this design in the field. Further, testing will allow mathematical models to be validated …
-
Corrosion Studies of Molten Chloride Salt: Electrochemical Measurements and Forced Flow Loop Tests
… techniques and a forced convection loop. It explores corrosion thermodynamic properties, electrochemical corrosion kinetics, and flow-induced dynamic corrosion. The study developed a novel electrochemical method for measuring thermodynamic properties of corrosion products and …
-
Multiphase flow loop for the near horizontal hydronamics parameters measurement: Design, construction, and commissioning
The state-of-the-art laboratory scale flow loop was designed and constructed in this study. The flow loop allows the measurement of two-phase gas-liquid and three-phase gas-oil-water hydrodynamics and heat transfer characteristic through visualization and heat transfer sections. The inner pipe …
-
Rheology of hydrate slurries: transferability between a laboratory viscometer and a pilot scale flow loop
Includes bibliographical references (pages 107-110).
-
Development of a meso-scale flow loop facility to investigate scale deposition phenomena in pipes
… of scale deposition in pipes, an experimental loop was developed to generate inorganic salt deposition in a one-inch diameter pipe.Pre-heated water containing calcium and carbonate ions comes from a mixture tank and passes through a heated section of the pipe to accelerate scale precipitation …
-
Multiphase Flow Loop for the Near Horizontal Heat Transfer Parameters Measure-ment: Design, Construction and Commissioning
The multiphase flow loop for heat transfer experiment was designed, con-structed and commissioned by performing the preliminary test with two-phase air/water flow. The flow loop was designed so that it can be used for conducting a se-ries of heat transfer experiment on a high viscosity oil/air …
-
Transferability of hydrate kinetic inhibition results between bench scale apparatuses and a pilot scale flow loop, The
Includes bibliographical references (pages 189-197).
-
Design and Characterization of a High pressure Flow Loop for Heat Transfer Experiments of Supercritical Carbon Dioxide
… crucial phenomenon, a state-of-the-art closed flow loop was developed. This setup enabled convective heat transfer experiments of sCO2 under diverse boundary conditions and test section geometries. Key components of the loop include the test section, constant temperature bath, pump, flow meter, …
-
Integrated modeling to design a digital twin of the Massachusetts Institute of Technology molten salt irradiation flow loop
… of Technology's molten salt irradiation flow loop. By leveraging the SCALE nuclear analysis software suite—specifically the COUPLE, ORIGEN, and MAVRIC modules—along with analytical flow approximations, an integrated simulation was developed to predict gamma ray detector responses under …
-
Design of a high-pressure research flow loop for the experimental investigation of liquid loading in gas wells
… liquids from the wellbore. A review of existing flow loops worldwide revealed that specialized areas of research such as liquid loading in gas wells are still lacking dedicated test facilities. This project presents the design of a new dedicated facility to be located at the TowerLab at the …
-
Onset and Subsequent Transient Phenomena of Liquid Loading in Gas Wells: Experimental Investigation Using a Large Scale Flow Loop
… transient phenomena, using a large scale flow loop to visualize two-phase flow regimes, and to measure pressure and liquid holdup along a 42-m long vertical tube. From this investigation, it is possible to conclude that liquid loading should not be characterized based on onset criteria …
-
Vertical transport of solid particles in the ocean: phase I, development of a two-phase (solid-water) flow loop, instrumentation and data acquisition system
Includes bibliographical references (page 78).
-
Design and Construction of a Subcooled Boiling Flow Loop with an Internally Heated Vertical Annulus for Use in Testing Departure from Nucleate Boiling (DNB)
… of an apparatus to use in subcooled boiling flow experiments. A vertical annulus flow loop was design to mimic a rod used in a reactor boiler. The system was tested at different velocities and temperatures to verify it could be used in a range of experiments to try and match real world …
-
Quantifying a new horizontal well gas anchor performance
… used for the experiment is a transparent closed flow loop with horizontal wellbore configurations. Air and water were allowed to flow simultaneously creating a mixture at the inlet of the lateral section of the flow loop. The experiments were conducted in two folds: 1) With the tool in flow loop …
-
Characterization of local mass transfer rate downstream of an orifice
<p>Flow accelerated corrosion(FAC) results in wall thinning of pipes, tubes or vessels from exposure to flow due to corrosion. If FAC is not detected, it can lead to sudden failure of piping components. Orifices are used in piping systems to monitor and control the flow. Flow separation and …
Page 1 of 10