Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 210 for “"flow meter"”.

  1. A vibrating-reed mass-flow-meter.

    For many fluid-mass-rate-of -f low metering situations, a measure of the fluid's density-velocity product is required. The density -velocity (pv) product is multiplied by an effective conduit cross -sectional area to yield the mass-rate-of-f low. The area multiplication is accomplished by simply …

    nps Repository record for A vibrating-reed mass-flow-meter. (opens in a new tab)

  2. The construction of an improved milk flow meter

    Thesis (M.S.)--Michigan State University. Department of Agricultural Engineering, 1979

    msu Repository record for The construction of an improved milk flow meter (opens in a new tab)

  3. Partially Closed Valve Effects on Electromagnetic Flow Meter Accuracy

    … even result in a depleted resource. Generally, flow meters need a flow profile to be fully developed so to optimizemeasurement accuracy. In order to produce accurate measurements, most flow meters require a straight section of pipe immediately upstream of the meter. The straight pipe helps to …

    utahstate Repository record for Partially Closed Valve Effects on Electromagnetic Flow Meter Accuracy (opens in a new tab)

  4. The influence of viscosity on turbine flow meter calibration curves

    … Philosophy The influence of viscosity on turbine flow meter calibration curves by Ali Fakouhi Tlie sensitivity of the turbine flow meter to changes in fluid viscosity puts in question claims of accuracy (1%) and repeatability (.2%). The present results show that the output signal is a function of …

    soton Download PDF for The influence of viscosity on turbine flow meter calibration curves (opens in a new tab)

  5. Temperature Effect in Multiphase Flow Meter Using Slotted Orifice Plate

    Multiphase flow metering is one of the major focuses to develop in oil and gas industries. A combination of slotted orifice plate and electrical impedance technique was investigated in order to provide further development of a new type of multiphase flow meter. Flow visualization was conducted in …

    tamu Repository record for Temperature Effect in Multiphase Flow Meter Using Slotted Orifice Plate (opens in a new tab)

  6. Instability of stratified two-fluid flow in a Venturi flow meter

    … the subject of stability of stratified two-fluid flows in an inclined channel is examined and modelled using classical fluid dynamics. The problem is motivated by the consideration of oil-water flows through a Venturi flow meter in the oil industry. A background to both inviscid and viscous …

    oxford Repository record for Instability of stratified two-fluid flow in a Venturi flow meter (opens in a new tab)

  7. CFD Analysis of Viscosity Effects on Turbine Flow Meter Performance and Calibration

    <p>In this research turbine flow meters were studied, using computational fluid dynamics (CFD) modeling to the study effects of viscosity on the flow meters, across a wide range of operation, to improve our understanding and their performance. A three-dimensional computational model was created for …

    ut-knoxville Repository record for CFD Analysis of Viscosity Effects on Turbine Flow Meter Performance and Calibration (opens in a new tab)

  8. The Effects of Upstream Straight Pipe Length on Magnetic Flow Meter Accuracy

    … water systems, being able to accurately measure flow is absolutely essential. For many meter designs, including electromagnetic induction meters (also known as magnetic flow meters), the greatest accuracy is achieved when the device is calibrated correctly. Optimal meter accuracy often depends on …

    utahstate Repository record for The Effects of Upstream Straight Pipe Length on Magnetic Flow Meter Accuracy (opens in a new tab)

  9. The feasibility of micromachined dynamic resonant beam coriolis true mass flow meter

    … such as pressure sensors and accelerometers. MEMS flow sensing has emerged as a field of interest in microfluidics, with a variety of sensing methods being miniaturized, such as thermal anemometry, ultrasonic sensing and flow measurement based on the Coriolis effect. Coriolis sensing …

    njit Repository record for The feasibility of micromachined dynamic resonant beam coriolis true mass flow meter (opens in a new tab)

  10. Response of a slotted plate flow meter to horizontal two phase flow

    The slotted plate flow meter has been widely tested as an obstruction flow meter during the past several years. It has been tested for both single-phase flows as well as for two-phase flows. Previous studies have revealed that the slotted plate flow meter is always better in performance and …

    tamu Repository record for Response of a slotted plate flow meter to horizontal two phase flow (opens in a new tab)

  11. Capacitive Flow Meter Realtime Processing Using Cross Correlation HDL Design Methodology and Performance

    Accurate low cost flow rate measurements of multiphase varying rate flows would be beneficial to the oil and gas industries in Saskatchewan. This thesis provides a design methodology, implementation and analysis of the performance characteristics for data processing in a low cost real-time …

    regina Repository record for Capacitive Flow Meter Realtime Processing Using Cross Correlation HDL Design Methodology and Performance (opens in a new tab) Download PDF for Capacitive Flow Meter Realtime Processing Using Cross Correlation HDL Design Methodology and Performance (opens in a new tab)

  12. Simulation of Thermal Transit-Time Flow Meter for High Temperature, Corrosive and Irradiation Environment

    … challenges of providing reliable and accurate flow rate measurement is significant. In comparing with many other existing technologies for normal operation environments, correlated thermal transit-time flow meter show its advantages of resolving the challenges encountered in those harsh …

    unlv Repository record for Simulation of Thermal Transit-Time Flow Meter for High Temperature, Corrosive and Irradiation Environment (opens in a new tab) Download PDF for Simulation of Thermal Transit-Time Flow Meter for High Temperature, Corrosive and Irradiation Environment (opens in a new tab)

  13. Assessing the Effects of Local Turbulence and Velocity Profiles on Electromagnetic Flow Meter Accuracy

    … velocity profiles on electromagnetic (magnetic) flow meters. According to the American Water Works Association, “No tool available to water utilities has played a greater part in the conservation of water than the water meter (AWWA 2002).” Consequently, it is imperative to understand what …

    utahstate Repository record for Assessing the Effects of Local Turbulence and Velocity Profiles on Electromagnetic Flow Meter Accuracy (opens in a new tab)

  14. Design of a Novel Portable Flow Meter for Measurement of Average and Peak Inspiratory Flow

    … that accurately measures peak respiratory flows in situ is needed. This study provides a solution in the form of a novel portable flow meter design that accurately measures average and peak inspiratory flow of a user wearing an M40A1 respirator mask.

    maryland Repository record for Design of a Novel Portable Flow Meter for Measurement of Average and Peak Inspiratory Flow (opens in a new tab)

  15. The effects between two slotted plate flow meter under single, two, three components flow condition

    In previous work on the slotted flow meter, repeatibility and reproducibility were studied under different flow conditions and different configurations. In accordance with previous work, the effects of the distance between the slotted plate were identified as an area requring further investigation. …

    tamu Repository record for The effects between two slotted plate flow meter under single, two, three components flow condition (opens in a new tab)

Page 1 of 11