Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 156 for “"flow profile"”.
-
Interpretation of Array Production Logging Measurements in Horizontal Wells for Flow Profile
… of production logging in multi-phase flow wells is challenging, especially for highly deviated wells or horizontal wells. Flow regime-dependent flow conditions strongly affect the measurements of production logging tools. Segregation and possible back flow of denser phases result in …
-
Development of Specialized Laser Doppler Velocimeters for High Resolution Flow Profile and Turbulence Spectral Measurements
… are always in need of innovative instruments for flow velocity measurements. An ideal instrument would be non-intrusive, have a very fine spatial resolution as well as a very fine temporal resolution, be able to measure three-components of velocity, and be compact. Through recent advancements, …
-
Hyaluronan synthase 2 and hyaluronan in endothelial cells are increased by shear stress via the PI3-kinase-Akt-pathway with the most pronounced effect by an atheroprotective flow profile
… reduced at vessel sites with disturbed blood flow and low shear stress. Removal of hyaluronan by treatment with hyaluronidase results in a reduction of the ESL to less than 0.1 μm thick and impaired vessel dilatation properties. Recently, studies showed that distinct shear stress conditions …
-
Investigation of Melt Electrical Conductance in Food Extrusion
… The specific feeding load, barrel fill and flow profile were affected by the feed rate and the screw speed in opposite directions. Spread of the normalized RTD decreased with increasing feed rate while increasing screw speed broadened RTD due to more mixing. The flow profile in the extruder …
-
Partially Closed Valve Effects on Electromagnetic Flow Meter Accuracy
… even result in a depleted resource. Generally, flow meters need a flow profile to be fully developed so to optimizemeasurement accuracy. In order to produce accurate measurements, most flow meters require a straight section of pipe immediately upstream of the meter. The straight pipe helps to …
-
MASS FLOW MEASUREMENT IN THE INLET OF A TRANSONIC AXIAL COMPRESSOR
… into the test rig to provide more favorable flow conditions for more accurate measurement of the mass flow rate entering the rig. A computational fluid dynamics analysis was conducted using a 3-D model of the inlet of the test rig to obtain a preliminary prediction of the flow profile in the …
-
Evaluation of Fracture Stimulation Design Based on Downhole Temperature Interpretation
… are commonly used to diagnose downhole flow conditions. Although the technology allows us to qualitatively confirm the fluid flow profile and other issues occurring downhole during fracturing such as leakage through plugs, for optimizing the fracturing design, we also need to …
-
Development of a microfluidic model system to study the response of endothelial cells to pulsatile shear
… response of endothelial cell to pulsatile shear flow. The chip was manufactured in PDMS consisting of a peristaltic pump with pneumatic actuated microvalves and ‘ventricle’ connected to parallel-plate flow-cells with recirculation. In addition, cell loading, media and reagent replacement was also …
-
Nondimensional approach to the design of open channels with spatially varied flow
… equation is developed which describes the flow profile in rectangular channels with spatially varied flow. This equation is solved for various slopes and rates of discharge. The results show that when the slope and roughness are constant the dimensionless profiles are also constant over a …
-
Subclinical Atherosclerosis Quantified Through Cumulative Shear Measurement
… Increased surface relative roughness affects the flow profile transition from laminar to turbulent resulting in reduced shear rate. The relationship between the shear stress and the relative roughness was studied using a computer model for fluid flow. A model of the brachial artery was generated …
-
Modification and Optimization of Conducting Polymer-Modified, Redox-Magnetohydrodynamics (R-MHD) Pumping for Enhanced and Sustained Microfluidics Applications
… approach is scalable, tunable, generates flat flow profile, and does not require any channels or valves. Pumping performance, such as speed scales with the ionic current density (j) and duration depends on the total charge (Q). The ionic current density (j) results from the conversion of …
-
Effect of Surface Finish on Boiling Heat Transfer at Stagnation Point under Free Liquid Jet Impingement
… higher jet velocities which is attributed to the flow profile.</p> <p>For jet velocities lower than 2 m/s, the surface with higher <strong>Ra </strong>was found to have a delayed Onset of Nucleate Boiling ONB, higher Burn out Heat Flux BOF, and lower rate of heat transfer in the single phase …
-
An experimental investigation of the effects of swirling and pulsing the flow through an axisymmetric duct
It is known that the presence of swirl in a flow stream can affect heat and mass transfer rates, and pulsatile flow has important aspects in physiological studies and in non-steady turbulent flows. This investigation consisted of an experimental study of the generation and decay of swirling flow in …
-
Modeling and Optimization of Self-Healing Polymers
… studies, an ultimate aim is to predict the flow and macroscopic wound closures in polymeric materials. Corresponding numerical simulations to experimental results are presented, utilizing two mathematical models that describe bulk or layer flow. An optimization routine for this self-healing …
-
Production Log Analysis and Statistical Error Minimization
… methods and minimize the errors in interpreted profiles with statistical methods. After the investigation of all available standard production log interpretation methods, a new interpretation method for determining oil-water flow profiles was developed with temperature and flowmeter logs. Mass …
-
Predicting Flow in Firebrand Pile using Pore Network Model
… an in-depth understanding of heat transfer and flow profile within the firebrand pile. Modeling the firebrand pile as a fibrous porous medium, this study identified a porosity-permeability correlation that accurately describes the transport properties of a firebrand pile. The conduction-based …
-
An Analytical Approach to Utilize Temperature and Pressure Profile of a Multi-zone Well in Estimating Zonal Flow Contributions
… world face a major challenge in estimating zonal flow contributions in wells with multiple pay zones. This study develops an analytical approach that estimates zonal flow contributions from producing zones using the pressure and temperature profiles of the well. Such a method can assist operators …
-
Development and Evaluation of an Improved Microbial Inactivation Model for Analyzing Continuous Flow UV-LED Air Treatment Systems
… inactivation model for analyzing continuous flow UV-LED air treatment systems and use of the model to evaluate the impact of several treatment system design parameters on inactivation. Model development includes three submodels: a radiation submodel, a fluid flow submodel, and an inactivation …
-
Microfluidics Guided by Redox-Magnetohydrodynamics (MHD) for Lab-on-a-Chip Applications
… the important microfluidic features of flat flow profile and fluid circulation. MHD is driven by the body force, FB = j × B, which is the magnetic part of the Lorentz force equation, and its direction is given by the right hand rule. The ionic current density, j, was generated in an equimolar …
-
PARTICLE IMAGE VELOCIMETRY MEASUREMENTS OF THE TOTAL CAVOPULMONARY CONNECTION WITH CIRCULATORY FLOW AUGMENTATION
… in the inferior vena cava (IVC). Fluid velocity profiles were examined under various physiologic conditions for Fontan patients. The velocity profiles for all cases demonstrated the shunting of flow from the IVC toward the right pulmonary artery. A rotational component in the pump outflow was …
Page 1 of 8