Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 43 for “"flow rate measurement"”

  1. A flow rate measurement system for a mobile emissions measurement system.

    … is over-the-road testing. A Mobile Emissions Measurement System (MEMS) was developed by West Virginia University for over-the-road emissions testing. A component of this system is the flow rate measurement device, an Annubar, incorporated within a flow tube. To measure flow rate from this …

    wvu Repository record for A flow rate measurement system for a mobile emissions measurement system. (opens in a new tab)

  2. Flow rate measurement in a high temperature, radioactive, and corrosive environment

    Accurate measurement of coolant flow rate is essential for determining the maximum power required by the nuclear plant operation and critical for monitoring its operation safety. However, no practical off-the-shelf flowmeter is available to satisfy all the pressing multidimensional operation …

    unlv Repository record for Flow rate measurement in a high temperature, radioactive, and corrosive environment (opens in a new tab)

  3. Multiphase Flow Rate Measurement Using a Novel Conductance Venturi Meter: Experimental and Theoretical Study In Different Flow Regimes

    Multiphase flows, where two or even three fluids flow simultaneously in a pipe are becoming increasingly important in industry. Although much research has been done to measure the phase flow rates of two-phase flows using a Venturi meter, accurate flow rate measurements of two phase flows in …

    huddersfield Repository record for Multiphase Flow Rate Measurement Using a Novel Conductance Venturi Meter: Experimental and Theoretical Study In Different Flow Regimes (opens in a new tab)

  4. Assessments and Computational Simulations in Support of a Time-Varying Mass Flow Rate Measurement Technique for Pulsatile Gas Flow

    … the orifice meter. A dynamic absolute pressure measurement is also taken at the inlet of the orifice meter, along with a suitable temperature measurement of the mean flow gas. Together these three measurements allow for an incompressible CFD simulation (using a well-tested and robust model) for …

    mtu Repository record for Assessments and Computational Simulations in Support of a Time-Varying Mass Flow Rate Measurement Technique for Pulsatile Gas Flow (opens in a new tab)

  5. A novel fluidic flowmeter based on fluid oscillation phenomenon

    Accurate flow rate measurement is of prime importance in many areas, e.g. combustion control, process control, gas or water flowmetering and plant monitoring. A type of fluidic flowmeter for volumetric flow rate measurement, known as the target fluidic flowmeter, was investigated. The principle of …

    nanyang Repository record for A novel fluidic flowmeter based on fluid oscillation phenomenon (opens in a new tab)

  6. Non-Invasive Flow Measurement Via Distributed Acoustic Sensing Utilizing Frequency Spectra Analysis of Wall Pressure Fluctuations

    … sensing to noninvasively measure volumetric flow rate via multiple unique sensor styles. This work modifies previously used methods of flow detection via fiber optic acoustic sensors affixed onto the exterior body of a flow apparatus. Flow rate measurement methods for two unique sensor styles …

    vt Repository record for Non-Invasive Flow Measurement Via Distributed Acoustic Sensing Utilizing Frequency Spectra Analysis of Wall Pressure Fluctuations (opens in a new tab)

  7. Venturi Flowmeter Performance Installed Downstream of the Branch of a Tee Junction

    … to evaluate the influence of a tee junction on flow rate measurement of a Venturi flowmeter installed downstream of the branch of a tee. Accuracy in flow measurement is important to organizations where miscalculated flow rates can add up to be millions of dollars in either lost revenue, …

    utahstate Repository record for Venturi Flowmeter Performance Installed Downstream of the Branch of a Tee Junction (opens in a new tab)

  8. Chute flow experiments

    … is to study the behavior of granular materials flowing down an inclined chute using three diagnostic techniques under different chute inclination angles and chute floor conditions. The three methods are: (1) tracking the motion of single particle within the mass in a noninvasive manner using a …

    njit Repository record for Chute flow experiments (opens in a new tab)

  9. Asymmetric flow measurement in space constrained cooling water ducts using a traversing probe

    … research was to identity and recommend a type of flow measurement technique suitable for flow measurements in the CW ducts. After conducting a literature survey, the author restricted research to a local flow measuring technique as a result of physical constraints on site. In addition, the flow …

    cape-town Repository record for Asymmetric flow measurement in space constrained cooling water ducts using a traversing probe (opens in a new tab)

  10. Thermodynamic studies in flow metrology

    Thermodynamic studies in flow metrology were carried out to improve the realization of fluid flow quantities. First, a metrological competence study of the dynamic gravimetric gas mass flow rate measurement standard of MIKES was carried out. Then, a theoretical and experimental study to clarify the …

    aalto Repository record for Thermodynamic studies in flow metrology (opens in a new tab)

  11. The CMDS flow-rate and conductivity transducer : design, manufacture and testing

    … and functional requirements, a custom Flow-Rate And Conductivity Transducer (FRACT) was conceived, designed, and built for use in situ aboard the spinning rotor of the Centrifugal Membrane and Density Separation (CMOS) Research centrifuge. It was subjected to rigorous laboratory …

    uvic Repository record for The CMDS flow-rate and conductivity transducer : design, manufacture and testing (opens in a new tab)

  12. Evaluation of a Close Coupled Slotted Orifice, Electrical Impedance, and Swirl Flow Meters for Multiphase Flow

    … of a coupled slotted orifice and swirl flow meters, and a coupled slotted orifice and an impedance probe flow meter for multiphase flow is evaluated to develop a new multiphase flow meter. The slotted orifice also provides well homogenized flow for several pipe diameters downstream of …

    tamu Repository record for Evaluation of a Close Coupled Slotted Orifice, Electrical Impedance, and Swirl Flow Meters for Multiphase Flow (opens in a new tab)

  13. Simulation of Thermal Transit-Time Flow Meter for High Temperature, Corrosive and Irradiation Environment

    … the challenges of providing reliable and accurate flow rate measurement is significant. In comparing with many other existing technologies for normal operation environments, correlated thermal transit-time flow meter show its advantages of resolving the challenges encountered in those harsh …

    unlv Repository record for Simulation of Thermal Transit-Time Flow Meter for High Temperature, Corrosive and Irradiation Environment (opens in a new tab)

  14. Analyse des erreurs dues à l'écoulement dans la mesure de débit par la méthode acoustique : approches expérimentale et numérique

    The precise flow-rate measurement is a basic problem in the management and the exploitation of a hydraulic power-plant. The efficiency characterisation of an hydraulic machinery or of a water distribution net is linked to the accurate knowledge of the flow-rate. As well as the usual measurement …

    epfl Repository record for Analyse des erreurs dues à l'écoulement dans la mesure de débit par la méthode acoustique : approches expérimentale et numérique (opens in a new tab)

  15. Non-intrusive pressure measurement in microchannels

    A non-intrusive interferometric measurement technique has been successfully developed to measure fluid compressibility in both gas and liquid phases via refractive index (RI) changes. The technique, consisting of an unfocused laser beam impinging a glass channel, can be used to separate and …

    mtu Repository record for Non-intrusive pressure measurement in microchannels (opens in a new tab)

  16. Development of a test method to measure "in-use" emissions from stationary and portable diesel sources

    A cost-effective, accurate and easy-to-use in-field test method was developed that would allow regulatory bodies, such as the California Air Resources Board (CARB) to determine in-use compliance with emission standards for newly manufactured portable and stationary engines. As emissions measured …

    wvu Repository record for Development of a test method to measure "in-use" emissions from stationary and portable diesel sources (opens in a new tab)

  17. Monitoring the Stability of Anaerobic Digestion Using a Novel On-line Bicarbonate Alkalinity Monitor

    … The proposed method is based on a continuous flow rate measurement of carbon dioxide evolved from a continuous stream of sampled (<15cm3min-1 ) solution after saturation with gaseous C02 and subsequent acidification with excess acid. Measurement of bicarbonate in this way eliminates the …

    southwales Repository record for Monitoring the Stability of Anaerobic Digestion Using a Novel On-line Bicarbonate Alkalinity Monitor (opens in a new tab)

  18. Effect of Face Mask Leaks on Inhaled Corticosteroid Delivery to Infants

    … displacement. Face mask seal is quantified using flow rate measurement. The lung dose of beclomethasone dipropionate delivered via a Qvar® pressurized metered dose inhaler with AeroChamber Plus Flow-Vu™® Valved Holding Chamber and Small Mask, defined as that which passes through the nasal airways …

    alberta Repository record for Effect of Face Mask Leaks on Inhaled Corticosteroid Delivery to Infants (opens in a new tab)

  19. Sistema de Acumulação de Energia Solar Térmica com Módulo de Adsorção: Software de Controlo e Monitorização

    … to read and store temperature, pressure and flow rate data, and to control the position of the three system valves. The access to the built adsorption module prototype was not possible, so the program was not tested under real conditions. However, separate tests were conducted for each …

    coimbro Repository record for Sistema de Acumulação de Energia Solar Térmica com Módulo de Adsorção: Software de Controlo e Monitorização (opens in a new tab)

Page 1 of 3