Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 129 for “"flow test"”.
-
Passive Microfluidic Mixer Fabrication And Flow Test
… of microfluidic mixer fabrication and their flow test. Two different design based on a T-mixer were fabricated. J-shaped and vertical pillar micromixers were fabricated with Zeonor, PDMS, silicon and SU-8. Several methods were used to seal mixer and test the sealing effect. Using Cy5 and …
-
AC power control in the Core Flow Test Loop
… to design an a.c. power controller for the Core Flow Test Loop. The Core Flow Test Loop will be an engineering test facility which will simulate the thermal environment of a gas-cooled fast-breeder reactor. The problems and limitations of using sinusoidal a.c. power to simulate the power …
-
Development of a Particle Flow Test for Rotational Molding
One of the current testing method (the Dry Flow test) to qualify resin for use in production in the rotomolding process has been shown to have many flaws in both equipment and procedure. Research was done here to investigate a possible alternative that could eliminate some of these testing …
-
Automated control of a pebble bed core thermal flow test unit
The HTTF (Heat Transfer Test Facility) is a unique project verifying the only pebble bed correlations currently used by PBMR (Pty) LTD. They are developing a new concept nuclear power station and are at present in the preparation phase of the construction of the worlds first PBMR (Pebble Bed …
-
Characterization of bacterial biofilm biomass constituents, community structure, and metabolic activity in dynamic-flow test systems
… this knowledge gap has resulted from a lack of test systems and analytical techniques for examining bacterial colonization and biofilm formation under conditions which approximate those of in situ environments. This dissertation explores the effects of bulk-phase environments and surfaces on …
-
Investigation of surface roughness of natural rock fractures using high-resolution X-ray computed tomography and laboratory flow test measurements
Fluid flow through natural rock fractures is an important - and often dominant - factor in many aquifer and reservoir systems. Rock fractures are rough-walled, and this surface roughness introduces complexities. The analytically-derivable 'cubic law' describes laminar flow behavior through smooth, …
-
Design of a cold-flow test facility for the high-pressure fuel turbopump turbine of the space-shuttle main engine
… at the Naval Postgraduate School of a cold-flow test facility for the turbine of the high-pressure fuel turbopump of the Space Shuttle Main Engine, is reported. The specific article to be tested is the 'Alternate Development Model' designed and manufactured by Pratt & Whitney. The design of …
-
Hydraulic single-borehole techniques for characterizing hydraulic conductivity in highly permeable aquifers: Slug test, borehole flowmeter test, and dipole -flow test
… estimation of hydraulic conductivity, the dipole-flow test, the slug test, and the borehole flowmeter test were applied in two highly permeable aquifers. Modified procedures for the analysis of the data from each technique are proposed. The steady-state dipole flow test (DFT) was used to …
-
Development of a Highly Sensitive Protein Diagnostic Device using Isothermal Strand Displacement Amplification
The lateral flow test (LFT) is the preferred tool for detection of protein biomarkers in low-resource settings. While low-cost and rapid, these immunoassay devices often suffer from limited sensitivity in the single chemical step format. Our group has addressed this deficiency by coupling a lateral …
-
Numerical simulation of the rheological behavior of fresh concrete
… main methods for scientific investigation and testing of the fresh concrete were shown. The test methods were critically discussed in order to select the test, which has been used as a reference experimental test for the numerical simulations. Chosen reference experimental test was the slump …
-
Changes in Pregnancy - Associated Glycoproteins Associated with Fetal Age, Postpartum Interval and Evaluation of a Chute-side Lateral Flow Assay
… Pregnancy-associated glycoprotein pregnancy tests are gaining in popularity due to their ease of use and the unique feature of not requiring specialized training. Recently, a new lateral flow test (Alertys OnFarm Pregnancy Test) that does not require special equipment has been developed. A …
-
Odpovědnost statutárního orgánu v kontextu insolvence
… neschopnosti a předlužení, analyzuje nástroje testování insolvence (cash flow test, balance sheet test) a hodnotí modely finančního zdraví podniku (Altmanův index, IN05, Tafflerův model). Praktická část aplikuje tyto poznatky na případ společnosti MAMMOTH s.r.o., která čelí insolvenčnímu …
-
LATTICE BOLTZMANN METHOD AND CELLULAR AUTOMATA SIMULATION OF PARTICLE MOTION AND DEPOSITION IN 2-D CASE
… and Cellular Automata (CA) simulation in fluid flow and particle deposition. The current work focuses on incompressible flow simulation passing cylinders, in which we incorporate the LBM D2Q9 and CA techniques to simulate the fluid flow and particle loading respectively. For the LBM part, the …
-
Cold flow simulation of the alternate turbopump development turbine of the space shuttle main engine high pressure fuel turbopump
… at the Naval Postgraduate School of a cold-flow test facility for the turbine of the Space Shuttle Main Engine High Pressure Fuel Turbopump is reported. The article to be tested is the first stage of the Alternate Turbopump Development model designed and manufactured by Pratt & Whitney. The …
-
Isothermal Nucleic Acid Assays Based on Nucleic Acid Sequence Based Amplification (NASBA) and Recombinase Polymerase Amplification (RPA) for HIV-1 Diagnosis and Management in Low Resource Settings
… HIV live in the developing world. Nucleic acid tests (NATs) are necessary for early infant diagnosis and for monitoring patients receiving therapy. However, NATs cost $50-100 USD per test and require expensive thermal cycling equipment that may be unavailable in the developing world. This thesis …
-
An Investigation of Multicomponent Gas Flow in Tight and Shale Reservoirs
… gas industry. This study proposes a steady-state flow test using adsorbing and non-adsorbing gases of single and binary gas components through tight adsorbing and non-adsorbing cores to investigate the true permeability value of its diffusion and slip counterparts. A steady-state flow permeability …
-
2-D CFD design of the cross-sectional shape of arterial stents
… The solver is validated using well known fluid flow test cases and is shown to match other published computed results for bloodflow through stented arteries. New candidate stent shapes are produced by the optimization and are evaluated based on comparison to modern commercial stent designs.
Page 1 of 7