Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 180 for “"flowmeter"”.

  1. The electromagnetic flowmeter

    Abstract Not Provided.

    glasgow Download PDF for The electromagnetic flowmeter (opens in a new tab)

  2. Vortex shedding flowmeter pulsating flow CFD studies

    The computational analysis of vortex shedding flow is presented, using the commercially available computational fluid dynamics ( CFD ) software package PHOENICS. In this analysis it is shown how the use of the conventional PHOENICS default first-order hybrid-upwind convective differencing scheme …

    strathclyde Repository record for Vortex shedding flowmeter pulsating flow CFD studies (opens in a new tab)

  3. Modelling of calibration steam flowmeter test bench

    … test bench that serves to calibrate the steam flowmeters by using steam as working fluid. The test bench contains a condenser, the purpose of which is to condense the steam. By maintaining a steady-state regime, the weight of condensate measured during a given period of the time is used to …

    ets-quebec Download PDF for Modelling of calibration steam flowmeter test bench (opens in a new tab)

  4. Analysis of a cantilever coriolis mass flowmeter concept

    <p>A new flowmeter concept which simultaneously measures density, mean velocity, and mass flowrate has been conceived, analyzed, and experimentally verified. The concept is based on the dissipative effect of Coriolis inertial forces present in a vibrating hydroelastic cantilever. The concept also …

    utk-theses Repository record for Analysis of a cantilever coriolis mass flowmeter concept (opens in a new tab)

  5. Improving multi-phase performance of a Coriolis Flowmeter

    … performance of an existing Coriolis Mass Flowmeter (CMF) by sensor fusion with an additional differential pressure sensor. Core element of the concept is an empirical functional group of so-called acceleration factors that characterize the correlation of pressure drop over other flow …

    glasgow Repository record for Improving multi-phase performance of a Coriolis Flowmeter (opens in a new tab) Download PDF for Improving multi-phase performance of a Coriolis Flowmeter (opens in a new tab)

  6. Liquid Flowmeter Using Thermal Measurement; Design and Application

    This thesis presents flowmeter devices which can measure flowrate, pressure and temperature offlowing liquid samples using thermal measurement method. Typical thermal mass flowmeter usesthermal properties of materials to obtain flow features only for gases. We designed and fabricatedflowmeter …

    marquette Repository record for Liquid Flowmeter Using Thermal Measurement; Design and Application (opens in a new tab)

  7. The Analysis and Optimization of a Respiratory Flowmeter

    … PTMs studied are screen type resistive element flowmeters designed to efficiently measure respiratory gas volumetric flowrate at expiration and/or at inspiration. A mathematical model based on a force balance describes the PTM pressure drop across a single fine-mesh, square-weave wire screen. …

    marquette Repository record for The Analysis and Optimization of a Respiratory Flowmeter (opens in a new tab)

  8. A microcomputer-based averaging flowmeter using FORTH programming language

    <p>A flowmeter was designed and constructed to measure the average fluid flow over a ten-minute interval. The instrument used a bubbler system and differential pressure sensors to measure the density-compensated level in a sealed vessel. A microcomputer was used to record a fluid-level histogram …

    ut-knoxville Repository record for A microcomputer-based averaging flowmeter using FORTH programming language (opens in a new tab)

  9. In Vivo Evaluation of the NMR Limb Blood Flowmeter

    A control study of the NMR limb blood flowmeter was done for total pulsatile flow in arms and legs. Thirty three "normal" subjects were tested, to establish mean and peak to peak flow values, as well as variability. The results of this inter-subject test were compared to previously published …

    marquette Repository record for In Vivo Evaluation of the NMR Limb Blood Flowmeter (opens in a new tab)

  10. Development and analysis of a gas cantilever coriolis mass flowmeter concept

    <p>A concept of a cantilever Coriolis mass flowmeter for gas flow measurement has been developed and tested. This work draws from original work performed by W. R. Hamel, who developed the cantilever Coriolis flowmeter concept. The concept has been developed as an in line device utilizing a …

    ut-knoxville Repository record for Development and analysis of a gas cantilever coriolis mass flowmeter concept (opens in a new tab)

  11. Venturi Flowmeter Performance Installed Downstream of the Branch of a Tee Junction

    … junction on flow rate measurement of a Venturi flowmeter installed downstream of the branch of a tee. Accuracy in flow measurement is important to organizations where miscalculated flow rates can add up to be millions of dollars in either lost revenue, overcharges to the client, or improper …

    utahstate Repository record for Venturi Flowmeter Performance Installed Downstream of the Branch of a Tee Junction (opens in a new tab)

  12. An improved determination of calibration gas corrections for a typical thermal mass flowmeter design

    <p>The mass flow controller, or MFC, is a thermal flow device used extensively for the measurement and control of hazardous and corrosive process gases in the semiconductor industry. Calibration of the mass flow meter is conventionally performed using benign, non-hazardous surrogate gases, such as …

    ut-knoxville Repository record for An improved determination of calibration gas corrections for a typical thermal mass flowmeter design (opens in a new tab)

Page 1 of 9