Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 730 for “"flowrate"”
-
Evaluation of exhaust flowrate measurement techniques for a mobile emissions monitoring system
… the emissions concentrations the total exhaust flowrate through the engine must be determined. The devices evaluated were an Annubar, an Accutube, a hot film anemometer, a Pitot static tube, a venturi, and a vortex shedder.;The evaluation of the devices was broken down into two parts, the first …
-
Correlation of dissolved oxygen with flowrate and water temperature in the Passaic River Basin
… to Little Falls.</p><p>Having daily data of flowrate, water temperature and dissolved oxygen in the Passaic River at Little Falls from the U. S. Geological Survey for the latest ten years (1970-1980), this study has developed the relationships between dissolved oxygen (the present water …
-
Development of an experimental arrangement for measurement of evaporation through measurement of changes in flowrate
… which is due to an increase in the resulting flowrate. The evaporation rate is then calculated from this change in flowrate. These results are then compared with the results achieved from theoretical method. The results achieved from theoretical method indicated that the evaporation rate of …
-
The effects of platelet activating factor (PAF) on the arteriolar average blood velocity and volumetric flowrate in the microcirculation of the hamster cheek pouch
… red blood cell (RBC) velocity and volumetric flowrate were studied in twenty-four arterioles located in the cheek pouches of nine male syrian golden hamsters. The observed vessels were between 8-32um in diameter. These vesgs were subdivided further into two groups: 8-17um and the 21-32um …
-
Dynamic simulations of carbon dioxide pipeline transportation for the purpose of carbon capture and storage
… project aimed to study the effects of varying flowrates on the flow dynamics of carbon dioxide within a pipeline. The researched utilised the software gCCS to simulate three different transport system. The first system looked at the effects of transporting pure carbon dioxide in both the …
-
Evaluation of clamp-on ultrasonic liquid flowmeters
… flowmeter measures the fluid flow velocity and flowrate with the help of ultrasonic waves. Flow profile distortion due to pipe network disturbances cause uncertainty in the flowrate measurement. A numerical and experimental investigation is conducted to model the performance of a clamp-on …
-
Performance comparison of packed bed latent heat storage systems for medium temperature applications
… fluid in the experiments. The effect of the flowrate on the charging performance is evaluated using three charging flowrates namely; 4 ml/s (low), 6 ml/s (medium) and 8 ml/s (high). The storage system is also evaluated with three different set heater charging temperatures (260 oC (low), 280 …
-
Equivalent circuit modeling and analysis of microflow stabilization through compliant microchannels
… and analysis of the stabilization of pulsatile flowrates through a compliant microchannel. Flowrate stabilization leads to improved performance in microfluidic systems that use mechanically driven pressure sources, which inherently develop pulsatile flowrates. The hypothesis of this …
-
The fluid dynamics of the lower urinary tract
… technique for the measurement of urine flowrate simultaneously with bladder pressure has been developed and is discussed in Chapter 2. The method also permits the measurement of residual urine. The techniques used for the measurement of bladder pressure and abdominal pressure are also …
-
The Analysis and Optimization of a Respiratory Flowmeter
… is designed to measure respired gas volumetric flowrate. An instrumentation problem related to physiology is obtaining an accurate, efficient and economic measurement of respiratory gas flowrate in humans and laboratory test animals. This thesis develops the design criteria and the prototypes …
-
Influence of Magnetic Nanoparticles and Magnetic Stress on an Ionic Liquid Electrospray Source
… magnetic nanoparticles increased the required flowrate and extraction potential of the source, as well as the emission current at a given flowrate. The nanoparticles also influenced the beam divergence and energy of an electrospray, increasing and decreasing each respectively with higher …
-
Thermal performance representation and testing of air solar collectors
… of air solar collectors with an emphasis on flowrate and leakage effects. The thermal efficiency was evaluated using two methods. In the first method, referred to as the oulet mass flowrate method, the efficiency is based on the product of the outlet mass flowrate, the air specific heat and …
-
Ventiliatoriaus VKAP 200LD 2.0. slėgio-srauto charakteristikos ir naudingumo tyrimas /
… efficiency curves in all range of measured flowrate. Experimental and theoretical pressure-flowrate curves coinside in the range of midle and large flowrate. Presented methods of numerical modeling can be utilised in analysis of aerodynamic characteristic and efficiency of ducted fan used in …
-
Liquid Flowmeter Using Thermal Measurement; Design and Application
… presents flowmeter devices which can measure flowrate, pressure and temperature offlowing liquid samples using thermal measurement method. Typical thermal mass flowmeter usesthermal properties of materials to obtain flow features only for gases. We designed and fabricatedflowmeter devices with …
-
Flow resistance corrections for physical models using unit flowrates
… Evaluating physical models using a scaled unit flowrate provides a method by which the length-scale factor may be minimized. In this way, a scaled design discharge per unit width of channel is applied to a channel that is less wide than the prototype design. Using this approach greatly improves …
-
Characterization of Arterial Flow for Junctional Bleeding Control
This study investigated reducing volumetric flowrate under steady flow conditions by varying lengths of compression with constant cross-sectional area and varying cross-sectional area reduction with constant length in order to better understand how to control junctional hemorrhaging. The hypotheses …
-
Performance prediction model for positive displacement helical screw flowmeters
… loss for a given speed. This pressure loss times flowrate is then energy balanced against all internal loses. Pressure loss and speed are the reasons for leakage. Rotational speed times the theoretical swept volume is the theoretical flowrate and this flowrate, when combined with leakage flow can …
Page 1 of 37