Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 96 for “"fluid analysis"”.

  1. Pharmaceutical water systems: a thermal-fluid analysis of pipe dead-legs

    … most commonly used technique for flow exchange, fluid isolation and removal in pharmaceutical water systems, is the installation of a branch tee with a conventional two-way outlet port valve. This however can create a stagnant or “dead-leg” zone, which is particularly hazardous as bacteria can …

    dcu Download PDF for Pharmaceutical water systems: a thermal-fluid analysis of pipe dead-legs (opens in a new tab)

  2. Surfactant Design for EOR Project and Dynamic Surface Tension for Fluid Analysis

    … while formulating an optimal injection fluid for good field scale performance. In the pre-injection phase, laboratory measurements like contact angle and spontaneous imbibition experiments are performed to evaluate wettability alteration performance. The effects of chemical additives are …

    tamu Repository record for Surfactant Design for EOR Project and Dynamic Surface Tension for Fluid Analysis (opens in a new tab)

  3. A thermal-fluid analysis of piping dead-legs in high purity water systems

    … distribution loops are commonly used to divert fluid flow at take-off points. However fluid flow restriction at teesection branches can cause piping dead-legs. Dead-legs consist of reglons of stagnant fluid where harmful organisms can proliferate unaffected by the scounng effects of distribution …

    dcu Download PDF for A thermal-fluid analysis of piping dead-legs in high purity water systems (opens in a new tab)

  4. Coupled thermal-fluid analysis with flowpath-cavity interaction in a gas turbine engine

    … through a higher fidelity computational fluid dynamics (CFD) modeling of the inlet to the cavity, and a coupled finite element (FE) thermal to CFD fluid analysis of the cavity in order to accurately predict engine component temperatures. Accurately predicting temperature distribution in …

    iupui Repository record for Coupled thermal-fluid analysis with flowpath-cavity interaction in a gas turbine engine (opens in a new tab)

  5. Synovial fluid analysis used as an adjunct to diagnosis of canine joint diseases

    Thesis (M.S.)--Michigan State University of Agriculture and Applied Science. Dept. of Surgery and Medicine, 1962

    msu Repository record for Synovial fluid analysis used as an adjunct to diagnosis of canine joint diseases (opens in a new tab)

  6. Investigation and improvement of Wells turbine performance : fluid analysis & 2nd law of thermodynamics study

    … based only on the first law of thermodynamics analysis, without relying on the second law analysis. Since the second law of thermodynamics is concerned with the generation rate of entropy and accordingly the useful work, it is important to take the entropy generation rate into account while …

    strathclyde Repository record for Investigation and improvement of Wells turbine performance : fluid analysis & 2nd law of thermodynamics study (opens in a new tab)

  7. Analyzing Cannabinoid Stability in Different Conditions and Validating Novel Cannabinoids for Oral Fluid Analysis

    Oral fluid (OF) drug testing has been expanded to laboratory evidentiary confirmation testing in driving under the influence (DUI) cases. OF samples are collected by officers at the roadside using collection devices such as the Quantisal® device. Tetrahydrocannabinol (Δ9-THC) was the most prevalent …

    uab Repository record for Analyzing Cannabinoid Stability in Different Conditions and Validating Novel Cannabinoids for Oral Fluid Analysis (opens in a new tab)

  8. Thermal fluid analysis of combined power and desalination concepts for a high temperature reactor

    … to be R 2,486,958,689. The results and analysis for the different cycle configurations are presented in such a way that an easy comparison can be made.

    nwu-za Repository record for Thermal fluid analysis of combined power and desalination concepts for a high temperature reactor (opens in a new tab)

  9. A motion of freely oscillating droplet of a yield stress fluid: analysis and numerical studies

    … oscillations of a droplet of a yield stress fluid under the action of surface tension forces. The problem is treated both analytically and numerically. In particular, we address the question if there exists a finite stopping time for an unforced motion of a yield stress fluid with free …

    houston Repository record for A motion of freely oscillating droplet of a yield stress fluid: analysis and numerical studies (opens in a new tab)

  10. Evaluation of cytokines in the tumor microenvironment of lung cancer using bronchoalveolar lavage fluid analysis

    … by analyzing cytokines in bronchoalveolar lavage fluid (BALF). Materials and methods: Between January 2018 and June 2019, 119 patients were prospectively enrolled in this study. For each cancer patient, levels of 16 cytokines (fractalkine, granulocyte-macrophage colony-stimulating factor (GM-CSF), …

    zurich

  11. Guidelines for Optimizing Wireline Formation Testing and Downhole Fluid Analysis to Address Fault Transmissivity in the Context of Reservoir Compartment Connectivity

    Reservoir fluids are rarely found in homogeneous structures having homogeneous properties. The various elements and processes of the petroleum system result in complex fluid distributions and compositions. A sound understanding of these complexities can avoid disappointing results and costly …

    tamu Repository record for Guidelines for Optimizing Wireline Formation Testing and Downhole Fluid Analysis to Address Fault Transmissivity in the Context of Reservoir Compartment Connectivity (opens in a new tab)

  12. Application of simulated lung fluid analysis to characterize the influence of smelter activity on the respiratory bioaccessibility of nickel-bearing soils in Kalgoorlie, Western Australia

    … lung disease and analyzed using a simulated lung fluid to determine the concentration of nickel soluble in the lungs. The soluble nickel represents the fraction that may be involved in allergic or asthmatic reactions, while the insoluble compounds may be of concern as some are carcinogenic. …

    queens Repository record for Application of simulated lung fluid analysis to characterize the influence of smelter activity on the respiratory bioaccessibility of nickel-bearing soils in Kalgoorlie, Western Australia (opens in a new tab)

  13. Coefficient of isothermal oil compressibility for reservoir fluids by cubic equation-of-state

    … are usually obtained from reservoir fluid analysis. Reservoir fluid analysis is an expensive and time consuming operation that is not always available when the volumetric properties of reservoir fluids are needed. For this reason correlations have been developed and are being …

    ttu Repository record for Coefficient of isothermal oil compressibility for reservoir fluids by cubic equation-of-state (opens in a new tab)

  14. Pvt Simulators for Microcomputers

    Fluid analysis or pressure-volume-temperature (PVT) analysis of petroleum fluids can be obtained by either laboratory analysis, empirical correlations, or through the use of equations of state. Laboratory analysis is notably accurate but is expensive, time-consuming, and requires specialized …

    texas Repository record for Pvt Simulators for Microcomputers (opens in a new tab)

  15. The use of radioisotopes (Synovetin OA®) for the treatment of equine osteoarthritis

    … with respect to radiographs and/or synovial fluid analysis. Four horses with naturally occurring lameness due to OA were injected with Synovetin OA® intra-articularly. The horses were then monitored over a six-month period using an inertial-sensor system to measure the degree of lameness. …

    missouri Repository record for The use of radioisotopes (Synovetin OA®) for the treatment of equine osteoarthritis (opens in a new tab)

  16. Analog System-on-a-Chip with Application to Biosensors

    … SoC is developed with application to organic fluid analysis. The device contains a built-in self-test method for performing on-chip analysis of analog macros. The analog system-on-a-chip developed in this dissertation can be used to evaluate the properties of fluids for medical diagnoses. The …

    maryland Repository record for Analog System-on-a-Chip with Application to Biosensors (opens in a new tab)

  17. DESIGN AND OPTIMIZATION OF PERISTALTIC MICROPUMPS USING EVOLUTIONARY ALGORITHMS

    A design optimization based on coupled solid–fluid analysis is investigated in this work to achieve specific flow rate through a peristaltic micropump. A micropump consisting of four pneumatically actuated nozzle/diffuser shaped moving actuators on the sidewalls is considered for numerical study. …

    vcu Repository record for DESIGN AND OPTIMIZATION OF PERISTALTIC MICROPUMPS USING EVOLUTIONARY ALGORITHMS (opens in a new tab)

  18. A la frontière entre la pathologie cérébrovasculaire et neurodégénérative : un cas d'angiopathie amyloïde cérébrale

    … Additionally, biomarkers of the cerebrospinal fluid analysis showed a pattern suggestive of Alzheimer’s disease. After a review of the clinical presentations of cerebral amyloid angiopathy, magnetic resonance imaging biomarkers and their associated pathological findings will be discussed. The …

    liege Repository record for A la frontière entre la pathologie cérébrovasculaire et neurodégénérative : un cas d'angiopathie amyloïde cérébrale (opens in a new tab) Download PDF for A la frontière entre la pathologie cérébrovasculaire et neurodégénérative : un cas d'angiopathie amyloïde cérébrale (opens in a new tab)

Page 1 of 5