Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 32 for “"fluid removal"”
-
The pathophysiology of fluid removal during haemodialysis: implications for blood volume monitoring and determination of dry weight.
… demonstrate abnormal proportional compartmental fluid distribution and assess fluid shifts and PR during UF. A significant relationship was demonstrated between ECF change, PR and haemodynamic stability. The dissociation between simultaneous absolute and RBV measurements was explained by a …
-
A Novel Nonparametric Test for Heterogeneity Detection and Assessment of Fluid Removal Among CRRT Patients in ICU
… discrepancies in practiced and prescribed fluid removal, possibly related to the heterogeneity among these patients. With mixture modeling there have been several techniques in detecting heterogeneity with their specific limitations. In this dissertation a novel nonparametric ‘d test’ will …
-
Patients’ Perspectives of Fluid Management during Haemodialysis
… clinical support. Deciding what volume of fluid should be removed remains challenging: complications linked to excessive fluid removal are common and debilitating and “sharing decisions about my care” has consistently been rated one of the poorest aspects of patients’ experiences. However, …
-
Toward Optimal Adaptive Control of Hemodialysis
… treatments three times a week to remove excess fluid, excess substances, and waste products. In 20% to 30% of these treatments, significant drop in blood pressure, i.e., hypotension, occurs. Repeating intradialytic hypotension increases mortality of a patient. There were about 400,000 dialysis …
-
Negative Pressure Wound Therapy - Mechanisms of Action and Protecting Exposed Blood Vessels in the Wound Bed
… transducers. Wound contraction and wound fluid removal were also studied. Tissue pressure 0.1 cm from the wound edge decreased while an increase was found further (0.5 cm) from the wound edge. Increased tissue pressure is believed to be the result of wound contraction and wound edge tissue …
-
Blood Volume Monitoring Guided Ultrafiltration Biofeedback on the Reduction of Intradialytic Hypotensive Episodes in Hemodialysis
… disease rely on hemodialysis (HD) to maintain fluid balance. Unfortunately, rapid fluid removal [ultrafiltration (UF)] often results in symptomatic, intradialytic hypotension (IDH). Our objective was to perform a randomized controlled crossover trial to evaluate the effectiveness of a blood …
-
Pneumatic compression devices during hemodialysis
… water (-2.6 vs -2.3L, p=0.05) and intracellular fluid volume (-1.3 vs -1.1L, p=0.03), with no difference in extracellular fluid volume (-1.3 vs -1.2L, p=0.09) for PCDs vs control. Compared with standard of care, PCDs have no effect on intradialytic hemodynamic parameters, including CBV, although …
-
Development of 3D constructs that enable vascularization and tissue integration for therapeutic macro-device implants
… delivery and lymphangiogenesis for waste and fluid removal that are essential for long-term transplanted cellular therapies survival, therapeutic efficacy, and disease management. Here we investigate biomaterials, 3D fabrication approaches, pro-angiogenic and pro-lymphangiogenic approaches …
-
Θεραπείες νεφρικής υποκατάστασης σε ασθενείς με τελικού σταδίου καρδιακή ανεπάρκεια και καρδιονεφρικό σύνδρομο
… I in addition to intermittent extracorporeal fluid removal in terms of continuous venovenous hemofiltration at first and accordingly as out of hospital intermittent ultrafiltration, through permanent internal jugular catheters (Group RRT). Patients of both groups were followed up prospectively …
-
Fluid and blood pressure management in maintenance hemodialysis patients
… medications may change due to the removal of extracellular fluid by ultrafiltration and other factors. Because most blood pressure medications are vasodilators or impact other components of cardiovascular function, they may prevent the normal physiological response to changes in …
-
Characterising fluid status, distribution and dynamics in haemodialysis patients to improve fluid management strategies
Both the removal of too much and the failure to remove enough fluid during haemodialysis are associated with morbidity and mortality. It has been suggested that bioimpedance measurements using the Body Composition Monitor (BCM) and relative blood volume (RBV) monitoring can improve fluid …
-
Construção e validação do diagnóstico de enfermagem risco de volume de líquidos excessivo a partir de uma teoria de médio alcance
The nursing diagnosis of excessive fluid volume is frequently present in patients undergoing hemodialysis. This problem has negative repercussions on the health of these individuals, as it generates an increase in hospitalization rates, morbidity and mortality. Thus, preventing this problem is an …
-
Pore compressibility of reservoir sandstones from integrated laboratory experiments
… in optimization of hydrocarbon production. Fluid removal from a reservoir increases the effective stress causing reduction of porosity and permeability, and changes pore compressibility. While pore compressibility, and pore compressibility and porosity relationship have been studied …
-
The effects of epinephrine, AVP, norepinephrine, and acetylcholine on lung liquid production in in vitro preparations of lungs from fetal guinea pigs (Cavia porcellus)
… of epinephrine, norepinephrine, AVP and ACh on fluid movement by the lungs of the late-term guinea pig fetus. Catecholamines and AVP are secreted in high amounts by the fetus during delivery, and could be important with respect to fetal lung fluid removal; this event is vital at the time of …
-
Exploring Novel Intradialytic Techniques to Identify & Ameliorate of Hemodialysis-induced Myocardial Ischemic Injury
… due to the extracorporeal circuit and volume removal. The stress induced by intermitted hemodialysis is repetitive with cumulative cardiovascular effect and is the principal driver of heart failure and sudden death in this vulnerable population. The insults imposed by hemodialysis result in …
-
An investigation into the mechanisms, consequences and moderators of intradialytic hypotension in paediatric haemodialysis
… and priming of the HD circuit due to loss of fluid from the intravascular space. However data, largely in adults, challenged this hypothesis leading to a new consensus that intradialytic hypotension has a multifactorial aetiology. The uraemic milieu triggers a series of events that alters the …
-
Damping and Ejection of Sloshing Liquid Drops from Elastic Substrates
… and drop location. We explore highly-coupled fluid-solid mechanics using singular liquid drop with varying viscosity and surface tension resting on a millimetric cantilever. Cantilevers are displaced 0.6 mm and their free end is allowed to vibrate freely. Cantilever vibration causes drops to …
-
THE QUANTIFICATION OF NEUROCOGNITIVE IMPAIRMENT ACROSS THE SPECTRUM OF KIDNEY DISEASE
… oxygenation, mean arterial pressure, and fluid removal rates were observed. In summary, neurocognitive impairments are common in patients with kidney disease, particularly in perceptual-motor, attention, and executive function domains. Future studies will need to address how these …
-
Echocardiographic studies of the left ventricle in patients with chronic renal failure
… ventricular changes as a result of dialysis with fluid removal. Highly significant changes in all left ventricular diastolic dimensions were observed, indicating that the widely used method of determining LV mass is not suitable for serial assessment of dialysis patients who are subject to changes …
Page 1 of 2