Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 21 for “"focal plane detector"”
-
Building the sweeper magnet focal plane detector
Thesis (M.S.)--Michigan State University. Department of Physics and Astronomy, 2001
-
A Proposal for a High Resolution Focal Plane Detector
… effective way of constructing a high resolution focal plane detector for the Glasgow photon tagging spectrometer installed at Mainz. Chapter 1 summarises the objectives which must be met by such a detector and concludes which detectors should be further pursued. Chapter 1 also outlines and …
-
Karlsruhe Tritium Experiment: Detector System Commissioning and In-Situ PIN-Diode Array Dead-Layer Measurement
… spectrometer resolution, but a confluence of focal plane detector parameters contribute to the uncertainty in the measured neutrino mass including the detector backgrounds and the detector electron response function. The detector system group developed a figure of demerit, <italic>F</italic>, …
-
New detector technologies for astronomy
… usage. The primary technology discussed is the focal plane detector mosaic. A complete description of this new concept is given, covering the relevant background topics, including: image sensors; ranging from infra-red to X-ray wavebands, medium and large sized optical telescopes, imaging …
-
Development of the analyser module for the MIDAS Data Acquisition System operating on the K600 magnetic spectrometer at iThemba LABS, Cape Town
The focal-plane detector package at iThemba LABS, Cape Town, is reviewed and a new analyser module is developed. The mathematical methods employed by the analyser are also reviewed and the final system is calibrated and tested against experimental data taken at iThemba LABS, Cape Town.
-
High Depth Resolution Rutherford Backscattering Spectrometry with a Magnet Spectrometer: Implementation and Application to Thin Film Analysis
… spectrometer magnet and a Micro-Channel Plate - Focal Plane Detector (MCP-FPD) assembly. In this thesis, analytical and numerical studies of the spectrometer ion optics were conducted and their results compared to the actual magnet response to ensure the accuracy and quality of the HRBS output …
-
Gamma-Ray Spectroscopy of Neutron-Deficient Nuclides 129Nd, 131Pm and 132Pm
… (HPGe) JUROGAM γ-ray spectrometer and a suite of focal-plane detector systems to facilitate detailed studies of in-beam and isomeric delayed radiation emitted by various types of nuclides. Excited quantum states were populated in the highly neutron-deficient nuclides 129Nd, 131Pm and 132Pm …
-
A Determination of the 27Si(P,y) Reaction Rate Using its Mirror and its Importance in X-Ray Burst Nucleosynthesis
… low-cost, low-modification upgrade to the Oxford focal plane detector using Micromegas technology. The upgrade was very successful in improving the total energy loss resolution by as high as a factor of 3 and thus improving the particle identification ability of the detector. This leads to an …
-
Determining the 17F(α,p)20Ne Reaction Rate for Application in Type I X-ray Bursts
… the decay of of 17F, were made using NaI detectors at the John D. Fox Superconducting Accelerator Laboratory at Florida State University. We also measured the same reaction through inverse kinematics with a 20Ne beam on a polypropylene target at the Argonne Tandem Linac Accelerator System …
-
Heavy-ion reaction studies of nuclei far from stability
… a magnetic spectrograph, a normal incidence focal plane detector and a system for the production of very pure isotopic targets via ion implantation. Descriptions of these systems and associated techniques are presented.
-
Studying The Low-Lying Structure of 9B via The 10B(3He,a)9B Reaction
… Split-Pole Spectrograph (SE-SPS). The SE-SPS focal plane detector has particle identification capabilities that were used to isolate the reaction of interest. This experiment utilized the large solid-angle coverage of the Silicon Array for Branching Ratio Experiments (SABRE) at backward …
-
Image Restoration in the Presence of Bad Pixels
… sensors from nonuniform responsivity of the detectors in the focal plane detector array. Furthermore, some pixels can have extreme responsivities or simply be unresponsive altogether. Such "bad pixels" must be detected and addressed to provide the best possible imagery from a given sensor. …
-
Terahertz imaging with compressive sensing
… mechanical raster scanning. Other systems using focal plane detector arrays can acquire images in real time, but are either too costly or limited by low sensitivity in the terahertz frequency range. To design faster and more cost-effective terahertz imaging systems, the first part of this thesis …
-
Heavy-ion double charge exchange reactions as tools for 0bb decays. The 40Ca(18O,18Ne)40Ar reaction at 270 MeV by using MAGNEX
… magnetic spectrometer and detected by its focal plane detector. The energy spectra and angular distributions have been extracted. The data analysis of experimental results have established that the transition to 40Args: is dominated by the direct processes. Finally, an innovative technique …
-
A study of the (₉Be, ₁₀B) reaction
… and the design and testing of its 30 cm focal plane detector, which is of the "hybrid" type, is described. Despite the size of the counter, in particular the large cathode to Frisch-grid separation, the resolution of the ionization signals is comparable with that of smaller counters. The …
-
Evidence of Nuclear Rainbow in the 16O + 27Al elastic scattering @ 280 MeV
… magnetic spectrometer and detected by its Focal Plane Detector. In order to obtain wide elastic and inelastic angular distributions, five different angular settings were chosen, which covered a whole angular range from about 5° to about 40° in the laboratory reference frame. 27Al excitation …
-
Studio dello scattering 18O + 48Ti a 275 MeV, simulazioni Monte Carlo e caratterizzazione sperimentale del rivelatore di piano focale di MAGNEX per il progetto NUMEN
… la costruzione di un nuovo rivelatore di piano focale (Focal Plane Detector, FPD), costituito da un tracciatore a gas basato sulle M-THGEM e da un muro di rivelatori a telescopio ΔE-E, basato sulla tecnologia SiC-CsI(Tl), per l’identificazione delle particelle (Particle IDentification, PID). In …
-
Modeling and simulation of adaptive multimodal optical sensors for target tracking in the visible to near infrared
… systems (MOEMS) devices, optical systems, and detector arrays has resulted in a proof of concept for a state-of-the-art imaging spectropolarimeter sensor model that does not suffer from typical multimodal image registration problems. Test methodology developed for this work provides the ability …
-
Compressed sensing on terahertz imaging
… for real-time applications. Other systems using focal plane detector arrays can acquire images in real-time, but they are too expensive or are limited by low sensitivity in the THz range. More importantly, such systems cannot provide spectroscopic information of the sample. To develop faster and …
-
LANDSAT 5 Characterization Of Outgassing Effects On The Thematic Mapper Cold Focal Plane
Detector responses in Bands 5 and 7 to the Internal Calibrator in the Landsat 5 Thematic Mapper vary over time. The observed variations are sinusoidal in nature, and believed to be caused by a time-dependent material accumulation on a window of the cold focal plane dewar containing the detectors. …
Page 1 of 2