Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 77 for “"foot model"”

  1. A Biomechanically and Anatomically Realistic Foot Model (BAREFOOT)

    … studies, cadaver studies, and finite element model studies to conduct lower limb biomechanical research. In other realms of biomechanics, a fourth alternative has been recently introduced; strides have been made recently regarding realistic physical model-based studies in place of conventional …

    washington Repository record for A Biomechanically and Anatomically Realistic Foot Model (BAREFOOT) (opens in a new tab)

  2. Reliability of a Multisegment Foot Model in Shod Running

    … reliability of the Leardini multisegment foot model (LMFM) for tracking foot kinematics during barefoot and shod running without alteration of footwear. Eleven participants, five males (25.6±5 yrs, 73±15.8 kg, 1.75±0.05m) and six females (22.5±2.9 yrs, 66.6±7.2 kg, 1.71±0.05 m) granted …

    unlv Repository record for Reliability of a Multisegment Foot Model in Shod Running (opens in a new tab)

  3. Passive dynamic walking with knees : a point foot model

    In this thesis, a hybrid model for a passive 2D walker with knees and point feet is presented. The step cycle of the model has two phases of continuous dynamics: one with an unlocked knee configuration and a second one with a locked knee configuration. These stages are modeled as three-link and …

    mit Repository record for Passive dynamic walking with knees : a point foot model (opens in a new tab)

  4. APPLICATION OF A MULTI-SEGMENT FOOT MODEL DURING RUNNING

    … using optical motion capture systems involves modeling the foot as a single segment which limits the information on inter-segmental foot motion. Foot models have been shown to be reliable, but limited research is available that uses these foot models in conjunction with shoes. There are …

    uwo Repository record for APPLICATION OF A MULTI-SEGMENT FOOT MODEL DURING RUNNING (opens in a new tab)

  5. Validation of the multi-segment foot model with bi-planar fluoroscopy

    A multi-segment foot model (MSFM) is a useful tool for measuring foot joint kinematics although soft-tissue artefact is often present. Quantifying this error is needed to evaluate the accuracy of this model. This study validated the MSFM against bi-planar radiostereometric analysis (RSA) …

    uwo Repository record for Validation of the multi-segment foot model with bi-planar fluoroscopy (opens in a new tab)

  6. DEVELOPMENT AND VALIDATION OF KINETICS AND MUSCULOSKELETAL MODELING FOR THE MILWAUKEE FOOT MODEL

    Many children are afflicted by foot and ankle pathologies which affect the ankle, midfoot, and metatarsophalangeal joints. However, a clinically feasible foot model capable of assessing multi-segment kinetics throughout the gait cycle does not exist. Similarly, a musculoskeletal foot model …

    marquette Repository record for DEVELOPMENT AND VALIDATION OF KINETICS AND MUSCULOSKELETAL MODELING FOR THE MILWAUKEE FOOT MODEL (opens in a new tab)

  7. Clinical Meaningfulness of the Oxford Foot Model to Assess Foot Deformity during Gait

    The prevalence of foot deformity is globally high affecting populations across the lifespan. Foot deformity can be present from birth (such as clubfoot), emerge during growth/ present over-time (flat foot, hallux valgus), or occur following an injury or neurological event (cerebral palsy, stroke). …

    ucl Repository record for Clinical Meaningfulness of the Oxford Foot Model to Assess Foot Deformity during Gait (opens in a new tab)

  8. Implementing a multi-segment foot model in a clinical setting to measure inter-segmental joint motions

    … measuring inter-segmental joint motions of the foot using a dynamic method is required to evaluate the function and level of impairment of the foot joints. Optical motion tracking using the multi-segment foot model (MSFM) developed by Jenkyn and Nicole (2007), has been demonstrated to be a valid …

    uwo Repository record for Implementing a multi-segment foot model in a clinical setting to measure inter-segmental joint motions (opens in a new tab)

  9. A Multi-Segment Foot Model Analysis on Normal, Pes Planus and Pes Cavus Feet and Ankle Kinetics

    … on testing a clinically practical multi-segment foot model, in an optical motion capture laboratory, to analyse foot kinetics and the medial longitudinal arch (MLA) of the foot. The foot kinetics are analysed for differences between a control group with a normal/neutral arch foot anatomy, and two …

    uwo Repository record for A Multi-Segment Foot Model Analysis on Normal, Pes Planus and Pes Cavus Feet and Ankle Kinetics (opens in a new tab)

  10. Analysis of the hindfoot and tibia segment-based axes in the Oxford Foot Model - anatomy and accuracy

    The Oxford Foot Model (OFM) is a multi-segment foot model, which consists of three rigid segments (tibia, hindfoot and forefoot). The segments are defined by surface markers placed on bony landmarks on the foot and leg. The accuracy of the OFM angle calculations depends on how the markers and …

    oxford Repository record for Analysis of the hindfoot and tibia segment-based axes in the Oxford Foot Model - anatomy and accuracy (opens in a new tab)

  11. Effect of Fixation Using Locked Compression Plate versus Lag Screws on Biomechanics of Talonavicular Joint: A Human Cadaveric Foot Model

    … fusion is a surgery used for treating many hind foot pathologies. A problem associated with the procedure is non-union which may be due to inadequate stabilization. The objective of our study was to compare the effect of two surgical fixation techniques on the motion and biomechanics of the …

    tenn-hsc Repository record for Effect of Fixation Using Locked Compression Plate versus Lag Screws on Biomechanics of Talonavicular Joint: A Human Cadaveric Foot Model (opens in a new tab)

  12. A novel analytical pipeline quantifying variance in foot morphology and function using statistical shape modelling and a 26-segment foot model.

    … outline an approach applying a statistical shape model and developing a 26-segment patient specific foot model to identify relationships between foot posture and function. The premise of structural and functional variance between different foot arch types exists, however an analytical pipeline …

    whiterose Repository record for A novel analytical pipeline quantifying variance in foot morphology and function using statistical shape modelling and a 26-segment foot model. (opens in a new tab)

  13. Quantitative analysis of the kinematics of the foot during gait with respect to barefoot running shoes using a Multi-Segment Foot Model

    Kinematics of the foot during static and dynamic tasks are technically challenging to accurately measure, making it difficult to evaluate their contribution to running-related injuries. Motion capture can detect changes in running mechanics, such as with differing footwear. Habitual barefoot …

    uwo Repository record for Quantitative analysis of the kinematics of the foot during gait with respect to barefoot running shoes using a Multi-Segment Foot Model (opens in a new tab)

  14. To develop a clinically friendly multi-segment kinematic and kinetic foot model and test it on pre-/post-HTO patients with medial knee osteoarthritis and knee varus

    … to develop a clinically useful multi-segment foot model that will enable the analysis of foot kinematics and kinetics in an optical motion capture laboratory setting. This study will also test the new multi-segment foot model on patients with knee osteoarthritis and varus knee alignment that …

    uwo Repository record for To develop a clinically friendly multi-segment kinematic and kinetic foot model and test it on pre-/post-HTO patients with medial knee osteoarthritis and knee varus (opens in a new tab)

  15. Methods of Estimating Foot and Ankle Power in Takeoff Phase of Standing Vertical Jump

    … capture studies have commonly considered the foot as a single rigid body. However, the presence of internal joints as well as soft-tissue interactions inside the foot demonstrate that the foot is in fact not rigid. Various methods have been applied to study the deviations of the foot from …

    gvsu Repository record for Methods of Estimating Foot and Ankle Power in Takeoff Phase of Standing Vertical Jump (opens in a new tab)

  16. MODELOS CINEMÁTICOS MULTISSEGMENTARES DO COMPLEXO TORNOZELO-PÉ: influência sobre ângulos relacionados à pronação-supinação do pé na postura e na marcha

    Abnormal pronation of the foot is related to various musculoskeletal conditions. Multisegmental Foot Models have been used to measure kinematic foot parameters, including those reporting on pronation / supination. The present study investigated the differences in the articular and segmental angles …

    brazil-ufmg Repository record for MODELOS CINEMÁTICOS MULTISSEGMENTARES DO COMPLEXO TORNOZELO-PÉ: influência sobre ângulos relacionados à pronação-supinação do pé na postura e na marcha (opens in a new tab)

  17. Extended Biomechanical Model of the Ankle-Foot Complex: Incorporation of Muscles and Ligaments

    Current musculoskeletal foot-ankle models have a limited complexity and therefore they are not able to capture the full functionality of the foot-ankle complex. However, in the context of the Aladyn project, which aims at developing custom insoles with dynamic structures through 3D printing, there …

    coimbro Repository record for Extended Biomechanical Model of the Ankle-Foot Complex: Incorporation of Muscles and Ligaments (opens in a new tab)

  18. Gait Alterations and Plantar Pressure in Diabetic Peripheral Neuropathy: A Preliminary Study

    … integrated a full-body analysis with a detailed foot model. Purpose: To assess PP and gait alterations in DPN by controlling walking speed and incorporating a multisegment foot model into a full-body gait analysis. We hypothesize that hip and ankle kinetics will be altered consistent with distal …

    byu Repository record for Gait Alterations and Plantar Pressure in Diabetic Peripheral Neuropathy: A Preliminary Study (opens in a new tab)

  19. The selection, instrumentation and calibration of a low range pressure transducer for use in Webb Institute Towing Tank experiments

    … selected for use with Webb Institute Towing Tank models in making pressure and velocity surveys. The instrumentation of this transducer included a 14 watt variable frequency power supply, a 1000 cycle filter, a cathode-ray oscilloscope, and a transducer output amplifier as an optional component. …

    nps Repository record for The selection, instrumentation and calibration of a low range pressure transducer for use in Webb Institute Towing Tank experiments (opens in a new tab)

  20. Effects of Ankle Actuation on Stability and Gait Dynamics in Oscillatory Bipedal Walking

    … problems in robotics and biomechanical modeling due to its inherent instability, underactuation, and the complexity of human gait dynamics. This study presents the design and control of a planar bipedal walking model developed to analyze the role of ankle control in achieving stable and …

    denver Repository record for Effects of Ankle Actuation on Stability and Gait Dynamics in Oscillatory Bipedal Walking (opens in a new tab)

Page 1 of 4