Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"force gauge"”.

  1. Three-Dimensional Flow Measurements Around a Mechanical Flapping Wing

    … thrust generated by the MAV are measured using a force gauge. The wing tip is tracked in 2D and 3D for synchronization of the measured lift forces with the flow field measurements from the SAPIV. The positive and negative circulation are plotted against the measured lift and thrust forces. The …

    byu Repository record for Three-Dimensional Flow Measurements Around a Mechanical Flapping Wing (opens in a new tab) Download PDF for Three-Dimensional Flow Measurements Around a Mechanical Flapping Wing (opens in a new tab)

  2. An Investigation of the Effects of N-Butanol on Friction and Wear Patterns When Mixed with Ultra Low Sulfur Diesel

    … wear rates and changes in the frictional force in the internal combustion engines in which they are used. The change in viscosity is much the same as when the diesel is mixed with other biodiesel alcohols but at a greater rate; in fact, the viscosity of the mixture is less than the …

    gsu Repository record for An Investigation of the Effects of N-Butanol on Friction and Wear Patterns When Mixed with Ultra Low Sulfur Diesel (opens in a new tab)

  3. Primate-Plant Interactions in the Tropical Dry Forests of Northwestern Madagascar: Seed Dispersal and Sensory Ecology of Eulemur fulvus.

    … fruit puncture resistance using a modified force gauge and fruit odor using XAD filtration and gas chromatography-mass spectrometry. I determine that many ripe fruits colors are conspicuous to brown lemurs against a background of leaves, and that ripe fruits are significantly different …

    toronto-retro Repository record for Primate-Plant Interactions in the Tropical Dry Forests of Northwestern Madagascar: Seed Dispersal and Sensory Ecology of Eulemur fulvus. (opens in a new tab)

  4. The analytical force prediction and dynamic response analysis of the Bristol H25A compressor

    … research is to perform an in-depth study of the force components within the H25A compressor along with a computer simulation program and the dynamic response analysis of the compressor internals using the finite element method. The model tor force prediction was created based on the assumption …

    vt Repository record for The analytical force prediction and dynamic response analysis of the Bristol H25A compressor (opens in a new tab)

  5. Drag measurements across patterned surfaces in a low Reynolds number Couette flow facility

    … bearings on a slide system that connects to a force gauge used to measure the drag. Within the gap between the model and moving belt a Couette flow with a linear velocity profile was created. Digital particle image velocimetry was used to confirm the velocity profile. A patterned surface, in …

    alabama Repository record for Drag measurements across patterned surfaces in a low Reynolds number Couette flow facility (opens in a new tab)

  6. Motor models in action prediction : a test of practice experience generalization when throwing darts with a weight

    … incongruent movement task (light press on a force gauge) after physical practice. Both physical and perceptual practice resulted in improvement in prediction accuracy post-practice, although this was strongest for the no-weight physical practice group. Overall, these data provide evidence …

    ubc Repository record for Motor models in action prediction : a test of practice experience generalization when throwing darts with a weight (opens in a new tab) Download PDF for Motor models in action prediction : a test of practice experience generalization when throwing darts with a weight (opens in a new tab)

  7. Changes in Cellular and Biomechanical Properties in the Rat Gastrocnemius Muscle Complex Following Injection of Platelet Rich Plasma and Traumeel®S Post Calcaneal Tenotomy

    … tension was measured in vivo using a Shimpo force gauge. Histological analysis included measurement of myofibre diameter with bright field microscopy, and percentage/thickness of collagen with polarizing microscopy. Western blot analysis was used to study the time course of TGF-1 and b-FGF …

    toronto-retro Repository record for Changes in Cellular and Biomechanical Properties in the Rat Gastrocnemius Muscle Complex Following Injection of Platelet Rich Plasma and Traumeel®S Post Calcaneal Tenotomy (opens in a new tab)

  8. Tesla Turbine Torque Modeling for Construction of a Dynamometer and Turbine

    … turbine stall torque was measured using a spring force gauge. Two methods were chosen to model Tesla turbine stall torque: 1) flow over flat plate and 2) free vortex with a sink. A functional dynamometer and thermodynamic apparatus were constructed once the model was confirmed to be within the …

    unt Repository record for Tesla Turbine Torque Modeling for Construction of a Dynamometer and Turbine (opens in a new tab)

  9. Development of a novel endoscopic platform for the treatment of gastrointestinal conditions

    … handle and an external unit which together exert forces on any suitable flexible instruments in order to produce up to five degree of independent instrument movement. The design and construction of the twin channel endoscopic platform is performed using computer aided design and rapid prototyping …

    strathclyde Repository record for Development of a novel endoscopic platform for the treatment of gastrointestinal conditions (opens in a new tab)

  10. Microcurrent treatment on pain, edema, and decreased muscle force associated with delayed onset muscle soreness: a double-blind, placebo, study

    … angle (biceps shortening), and biceps isometric force. Objective: To investigate the effect of two different microcurrent electrical neuromuscular stimulation (MENS) protocols on delayed onset muscle soreness (DOMS) of the biceps muscles. Background: Microcurrent treatment is gaining popularity …

    hawaii Repository record for Microcurrent treatment on pain, edema, and decreased muscle force associated with delayed onset muscle soreness: a double-blind, placebo, study (opens in a new tab)

  11. Ενδαγγειακή αποκατάσταση ανευρύσματος κοιλιακής αορτής: μηχανικές ιδιότητες που συμβάλλουν στη στήριξη του ενδομοσχεύματος

    … or iliac artery with running PTFE suture. Distal force was applied to the flow divider of each graft, either fully or only proximally deployed, via a sensitive force gauge. Minimum displacement force (DF) needed to dislodge the stent graft from the infrarenal neck was recorded. Measurements were …

    greece Repository record for Ενδαγγειακή αποκατάσταση ανευρύσματος κοιλιακής αορτής: μηχανικές ιδιότητες που συμβάλλουν στη στήριξη του ενδομοσχεύματος (opens in a new tab)

  12. Estimation of Position and External Force of Cable Driven Surgical Robots

    … To measure this initial tension, a special force gauge sensor can be used; however, these sensors are expensive and in some applications, such as surgery, it is not practical due to sterilization requirement. It is found that the stiffness parameter of cables has the highest correlation with …

    washington Repository record for Estimation of Position and External Force of Cable Driven Surgical Robots (opens in a new tab)

  13. Therapeutic Potential of Acute Intermittent Hypoxia (AIH) In Early Repair of Decompressed Peripheral Nerves

    … injuries were performed using mechanical force gauge sensor linked to a data acquisition system, allowing reproducible and consistent unilateral compression injuries in adult male Lewis rats, delivering 14 grams of force on each of a series of 4 constriction sites over a distance of 3mm. I …

    sask Repository record for Therapeutic Potential of Acute Intermittent Hypoxia (AIH) In Early Repair of Decompressed Peripheral Nerves (opens in a new tab) Embargoed until 2027-10-03

  14. The Effect of Size and Location of Composite Attachments on the Extrusive Force Delivered to a Maxillary Central Incisor by a Clear Aligner

    … effect of attachment size and location on the force delivered to a maxillary central incisor by a clear aligner has not been reported. Aim: To evaluate the effect of composite attachment size and location on the extrusive force delivered to a maxillary central incisor with a Zendura FLX clear …

    umn Repository record for The Effect of Size and Location of Composite Attachments on the Extrusive Force Delivered to a Maxillary Central Incisor by a Clear Aligner (opens in a new tab)

  15. The Effect of Lumbar Posture and Pelvis Fixation on Back Extensor Torque and Paravertebral Muscle Activation

    … adopted during lifting is thought to alter the force capabilities of the trunk and the active contribution of the paravertebral muscles. To date, most studies examining back extensor (BE) force and muscle activation have been undertaken in non-functional positions with the pelvis fixated. …

    auckland-tech Repository record for The Effect of Lumbar Posture and Pelvis Fixation on Back Extensor Torque and Paravertebral Muscle Activation (opens in a new tab)

  16. Early Time (E1) High Altitude Electromagnetic Pulse Effects on Lightning Surge Arresters and Trip Coils

    … state of health measurement comprises a peak force measurement using a force gauge, and an internal impedance measurement, using a vector network analyzer and an LCR meter. Impedance is presented as plots, where it is measured and displayed in a wide frequency range. The force measurement …

    unm Repository record for Early Time (E1) High Altitude Electromagnetic Pulse Effects on Lightning Surge Arresters and Trip Coils (opens in a new tab)

  17. The Effect of Attachment Flash on Clear Aligner Force Delivery

    … flash thickness and surface area has on the force delivered to a maxillary central incisors with a Zendura FLX clear aligner. Methods: The experiment was conducted in a lab setting using 3D printed models of the maxillary arch. Zendura FLX .030 mil clear aligners programmed for 0.25 mm of …

    umn Repository record for The Effect of Attachment Flash on Clear Aligner Force Delivery (opens in a new tab)

  18. Comparing the Kinematic and Kinetic Outputs from Digital Human Modeling Tools to a Lab-Based Rigid-Link Model for the Investigation of Musculoskeletal Disorder Hazards During Patient Handling

    … healthcare providers (HCPs) to high bone-on-bone forces, resulting in the development of musculoskeletal disorders (MSDs) (Fragala,2011). Researchers have been able to estimate biomechanical exposures during patient turning using kinematic and kinetic data collected from HCPs (e.g., Marras et al., …

    waterloo Repository record for Comparing the Kinematic and Kinetic Outputs from Digital Human Modeling Tools to a Lab-Based Rigid-Link Model for the Investigation of Musculoskeletal Disorder Hazards During Patient Handling (opens in a new tab)

  19. Quantifying the Ergonomic Impact on Healthcare Workers Using a Needle-free Injector Device

    … among US hospital healthcare workers. Yet the forces required to set and trigger devices using spring mechanisms for medication delivery have not been explored. This laboratory experiment measured forces exerted by healthcare workers (HCWs) using a particular jet injector approved by FDA in …

    usf Repository record for Quantifying the Ergonomic Impact on Healthcare Workers Using a Needle-free Injector Device (opens in a new tab)

  20. Přehled současných metod a zařízení pro měření součinitele tření v mazaném kontaktu třecích povrchů

    V této práci byla rozebrána problematika měření koeficientu tření. Byl definován pojem tření a okrajově popsány základní fyzikální metody určování koeficientu tření. Práce byla převážně zaměřena na moderní pokročilé metody měření koeficientu tření, realizované pomocí experimentálních přístrojů – …

    brno-tech Repository record for Přehled současných metod a zařízení pro měření součinitele tření v mazaném kontaktu třecích povrchů (opens in a new tab)

Page 1 of 2