Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 200 for “"force plates"”.
-
Markerless Motion Capture and Force Plates Utilizing Machine Learning and its Utility to Identify Musculoskeletal Injuries in Marine Officer Candidates
… such as markerless motion capture (mMoCap) and force plates (FP) and allow for field expedient measures in dynamic military settings. The aim of this dissertation are in three parts, 1) evaluate the efficacy of commercial grade screening technology black box algorithms to predict MSKI using …
-
Design and Validation of a Wearable SmartSole for Continuous Detection of Abnormal Gait
… testing against the industry standard force plates. In total, 14 participants were selected for gait studies, 7 with pronounced gait abnormalities (e.g. limps), and 7 with physiological gait. Parameters of interest included stance time, gait cycle time, and the ratio of the force …
-
APE-V: athlete performance evaluation using video
… and drop jumps performed on bilateral force plates provide a wealth of metrics; however, detailed evaluation of this movement requires specialized equipment (force plates) and trained experts to interpret results, limiting its use. Computer vision techniques applied to videos of such …
-
Developing a User-Independent Deep Learning-Based Biomechanical Gait Analysis System Using Full Body Kinematics and Electromyography
Motion capture (mocap) systems integrated with force plates and electromyography (EMG) collect detailed kinematic and kinetic data on subjects, including stride length, width, cadence, speed, and other spatiotemporal parameters. These systems allow clinicians and researchers to analyze movements, …
-
Using Inertial Foot Pods to Develop a Gait Protocol to Assist with Concussion Diagnosis and Monitoring
… were that 3D motion capture (3D MOCAP) and force plates were the most commonly used technologies for analysing concussive gait, with only a few researchers incorporating the use of inertial sensors. A multitude of outcome variables were used to determine differences with concussive and …
-
The effect of acute fatigue on reactive strength index in modern dancers
… female, 4 male) participated in this study. Two force plates were utilized to record the force-time data during drop jumps (DJ) before and after an acute, fatiguing protocol. Dancers performed a 5-10 minute self-selected warm up followed by 3-5 practice trials of DJs onto the force plates. Three …
-
Integration of Force Sensors in Cross-Country Ski Bindings and Concept Development for Multi-Sport Measurement Platforms
Accurate force measurement is an essential component in sports science, providing valuable insights into biomechanics, performance, technique, and equipment interaction. Skisens, a Swedish sports technology company, pioneered the introduction of force measurement in cross-country skiing, through …
-
Development and clinical bench testing of a Matlab based, user friendly, deployable software application for automatic batch processing of fully instrumented three-dimensional human movement biomechanics data
… capture systems in conjunction with data from force plates. The information is processed with kinematic and kinetic models which output vast amounts of data. For analysis, gait data is separated into individual cycles and normalized from 1-100% where certain events are expected to occur at …
-
Pedestrian-induced lateral excitation of footbridges
… <p>Participants were recorded walking over force plates in a gait laboratory so their normal ground forces could be compared to each other and the IPM. High inter-subject variability and low intra-subject variability were observed. The IPM did not reproduce transient components of the ground …
-
Understanding gait analysis: variability of data collected with a pressure sensitive walkway
… calibration protocols assessing canine gait. Force plates are considered to be the gold standard method of kinetic gait analysis. Although pressure sensitive walkways produce comparable results to force plates, there is great variability in the results reported amongst pressure sensitive …
-
Development of an electronic platform to quantify human knee function
… knee joint angular velocity, and ground reaction force. A sensor platform was developed to collect data for wearable motion analysis. Accelerometers were used to measure knee joint angle, gyroscopes were used to measure knee joint angular velocity, and Velostat force sensors were used to measure …
-
Normative Database of Adult Unilateral Trans-Tibial Amputee Gait
… and analyzed using a motion analysis system, force plates, and surface electrodes. Data were normalized to percent gait cycle and presented as an average of trials taken. Results of this study were similar to previously published literature. This database of amputee gait will help researchers …
-
Attentional requirements of postural control in people with spinal cord injury : the effect of dual task
… task (ST) trials were recorded: i) standing on force plates; ii) math task while seated; iii) RT task while seated. Two dual-task (DT) trials were recorded: i) standing + math task; ii) standing + RT task. The primary outcome measures were the change in performance between ST and DT between SCI …
-
Drive Leg and Stride Leg Ground Reaction Forces Relationship to Medial Elbow Stress and Velocity in Collegiate Baseball Pitchers
… torque in collegiate baseball pitchers using force plates, an inertial measurement unit, and a radar unit. The purpose of this study is to investigate the kinetic variables being measured and their relationship to pitch velocity and loads being placed on the medial elbow. Twelve collegiate …
-
Design and Evaluation of an Instrumented Equine Shoe for Kinetic Gait Analysis
… Current methods of kinetic gait analysis include force plates, instrumented treadmills, and instrumented horseshoes. All these devices measure Ground Reaction Forces (GRFs). Force plates are considered the gold standard for kinetic gait analysis but are unable to record successive strides. The …
-
Biomechanics of terrestrial locomotion in bats
… are more robust than those of other bats. I used force plates to test a prediction of the hindlimb-strength hypothesis that the peak hindlimb forces of walking vampire bats should be greater than the forces exerted by the legs of poorly crawling bats. I found that shuffling bats (Pteronotus …
-
Understanding the Value and Potential Future Technological Implementations of Anterior Cruciate Ligament Assessments within an NHS Environment
… of biomechanical technologies such as portable force plates, three-dimensional (3D) motion capture and markerless motion capture may offer valuable, objective insights, though each approach has distinct advantages and limitations. Aim: This thesis aimed to evaluate the value and potential …
-
Gait time series estimation using wearable sensors and machine learning techniques
… Employing Optical Motion Capture (OMC) and force plates is the gold standard method for 3DGA due to its accuracy and robustness. However, the challenges associated with this approach, such as high costs and limited accessibility, necessitate a thorough exploration of alternative approaches …
-
Incorporation of Pressure Insoles into Inverse Dynamic Analysis
… collection of body kinematics and the external forces prevailing during the task under evaluation. Current practice calls for kinematic data to be gathered using optical motion capture systems (OMC) and external forces, primarily ground reaction forces (GRFs), to be gathered using force plates. …
-
Biomechanical effect of therapeutic shoes
… speed across a walkway with two embedded force plates. Both in-shoe plantar pressure and gait kinematics and kinetics in the sagittal plane were collected. Therapeutic footwear showed significant effects on gait kinetics and kinematics at the ankle joint level and the effects diminished …
Page 1 of 10