Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 188 for “"force platform"”.

  1. The effect of repetition on force platform metrics during the bilateral bodyweight squat

    … was to analyze the vertical ground reaction forces (GRFvs) and center of pressure (CoP) stability metrics during the down phase, up phase and whole movement across the course of a 20 repetition set of the BWT squat in a recreationally competitive group of young adult women. It was …

    colostate Repository record for The effect of repetition on force platform metrics during the bilateral bodyweight squat (opens in a new tab)

  2. Comparing pressure measurement systems and a force platform as tools for equine gait analysis

    … has been well established through testing with force platforms. The force platform measures ground reaction forces in three orthogonal directions: mediolateral (Fx), craniocaudal (Fy) and vertical (Fz). Testing with force platforms has shown researchers that this technology is capable of …

    colostate Repository record for Comparing pressure measurement systems and a force platform as tools for equine gait analysis (opens in a new tab)

  3. Examination and Validation of the Fundamental Lower Extremity Mobile Testing System, and Identification of Best Practice to Mount Synthetic Turf to a Force Platform

    … cleat-turf interface is often examined using a force platform, an instrument commonly used in a biomechanical laboratory. Mobile surface testing instruments have been developed to examine traction characteristics and have rarely examined measurement agreement with the measurements taken by the …

    utk-theses Repository record for Examination and Validation of the Fundamental Lower Extremity Mobile Testing System, and Identification of Best Practice to Mount Synthetic Turf to a Force Platform (opens in a new tab)

  4. Validation of an inverse dynamics method to predict joint kinetics in the absence of dynamometry.

    … kinetics of human locomotion, ground reaction forces are typically measured directly using a force platform. In many different skills and movement environments, the utilization of a force platform to collect external force data is not possible. These particular movement situations require an …

    ottawa-retro Repository record for Validation of an inverse dynamics method to predict joint kinetics in the absence of dynamometry. (opens in a new tab)

  5. Maintaining Balance in Elderly Fallers: Novel aspects of postural balance measures in elderly

    … (risk of falling) and performance measurements (force platform) were used as outcome measures. The results of this study were a reduced risk of falling and less falls within the intervention group but no change of variables of the force platform. Based on this contrary result, the following …

    zurich

  6. Determining the validity of the Nintendo Wii balance board as an assessment tool for balance

    … by comparing it to the Bertec balance check platform and Kistler force platform. Design. Experimental Study Setting. UNLV research laboratory Patients or Other Participants. Twelve apparently healthy, male (n = 5) and female (n=7) subjects between the ages of 18 - 30 years (age = 23 ± 3 yrs.) …

    unlv Repository record for Determining the validity of the Nintendo Wii balance board as an assessment tool for balance (opens in a new tab) Download PDF for Determining the validity of the Nintendo Wii balance board as an assessment tool for balance (opens in a new tab)

  7. Biomechanical parameters of gait in subjects with total hip joint replacement and in healthy control subjects

    … AMTI (Advanced Medical Technology, Inc., 1991) force platform embedded in the center. Video data were collected and analyzed with the Peak5 Motion Measurement system (Peak Performance Technologies, Inc., 1993). Three-dimensional coordinates of each marker, force platform data, and anthropometric …

    twu Repository record for Biomechanical parameters of gait in subjects with total hip joint replacement and in healthy control subjects (opens in a new tab)

  8. Generalizability of Center of Pressure Measurements Across Age Populations

    … control of posture during quiet standing using force platform data lack standardization in measurement protocols (especially trial length and number). Guidelines for methodology that met acceptable reliability levels were established in both normal and altered visual conditions (Studies 1 and 2) …

    uiuc Repository record for Generalizability of Center of Pressure Measurements Across Age Populations (opens in a new tab)

  9. The Impact of Auditory and Visual Cognitive Tasks on Postural Control in Young Adults

    … modalities. Seventeen young adults stood on a force platform while simultaneously performing cognitive tasks of varying difficulty (easy, moderate and difficult), each presented auditorily and visually. Performing the moderate and difficult tasks precipitated a greater reduction in area of 95% …

    ottawa-retro Repository record for The Impact of Auditory and Visual Cognitive Tasks on Postural Control in Young Adults (opens in a new tab)

  10. The Effects Of Caffeine Supplementation On Vertical Jump Performance

    … effects of caffeine on vertical jump tests on a force platform. Methods: The study was a single-blind, randomized, crossover design. Participants consumed either caffeine (5 mg/kg body weight) or placebo. After a sixty-minute waiting period participants performed three squat jumps and three …

    nodak Repository record for The Effects Of Caffeine Supplementation On Vertical Jump Performance (opens in a new tab)

  11. Jump-landing movement quality in Icelandic youth natiopnal team basketball players

    … score was not significantly associated with any force platform variables in either CMJ condition (all p ≥ .13). Sex differences were observed for both jump height and relative peak landing force across both countermovement jump conditions (all p < .001), with males demonstrating higher values, …

    reykjavik Repository record for Jump-landing movement quality in Icelandic youth natiopnal team basketball players (opens in a new tab)

  12. Understanding the mechanisms that govern the impact behaviour of a football.

    … experimentally. Each football was projected at a force platform at a relatively low and high velocity. Measurements were captured using a combination of high-speed video and a force platform to characterise the impact response. The mechanical properties of each football were evaluated from a …

    sheffield-hallam Repository record for Understanding the mechanisms that govern the impact behaviour of a football. (opens in a new tab) Download PDF for Understanding the mechanisms that govern the impact behaviour of a football. (opens in a new tab)

  13. Desarrollo de herramientas para identificar factores biomecánicos de riesgo de la lesión de ligamento cruzado anterior a través de protocolo de instrumentación del drop jump en deportistas colombianos

    … with EMG and without resorting to the use of a force platform. Also, there is no agreement among scientists regarding the most relevant factors. Thus, this study’s purpose is to develop tools to identify the most relevant kinematic factors associated with the ACL injury by proposing a protocol …

    rosario Repository record for Desarrollo de herramientas para identificar factores biomecánicos de riesgo de la lesión de ligamento cruzado anterior a través de protocolo de instrumentación del drop jump en deportistas colombianos (opens in a new tab)

  14. Broadening the Capability of Kinetics Analysis in Biomechanics

    … designs in shoes might have on ground reaction force measures of performance. The second review and study evaluate methods of predicting ground reaction forces without the use of a force platform. A method of using effective forces and ways of improving its accuracy are evaluated in depth.

    denver Repository record for Broadening the Capability of Kinetics Analysis in Biomechanics (opens in a new tab)

  15. The Impact of Balance Disturbance on Cognition

    … were completed while participants stood on a force platform to measure postural sway during the three respective stances. While no differences in cognitive performance were evident based on level of balance challenge, sustained attention was predicted by both postural sway as measured by the …

    marquette Repository record for The Impact of Balance Disturbance on Cognition (opens in a new tab)

  16. Influences of Motor Control Instruction and Taping on Center of Pressure and Scapulothoracic Kinematics During Reaching for Individuals with Hemiparesis

    … both surface electromyographic data and force platform feedback. Design: This study utilizes a case-control design. Subjects: 5 control and 5 stroke survivors age >40 were recruited for this study through flyers at Burke Rehabilitation Hospital, White Plains, NY. Methods: Surface EMG …

    cuny-grad Repository record for Influences of Motor Control Instruction and Taping on Center of Pressure and Scapulothoracic Kinematics During Reaching for Individuals with Hemiparesis (opens in a new tab)

  17. Validation of seated postural control measures in non-ambulatory persons with Multiple Sclerosis

    … assessment involved participants sitting on a force platform without support for 30s. The center of pressure was determined based on the output of the force platform and the amount of seated postural sway was calculated. The FIST is a 14-Item clinical functional assessment of sitting balance …

    uiuc Repository record for Validation of seated postural control measures in non-ambulatory persons with Multiple Sclerosis (opens in a new tab)

  18. Reliability of a Multisegment Foot Model in Shod Running

    … Kinetic data was captured with an in-ground force platform (Kistler Instruments AG, Switzerland Model 9281B 60x40cm, 2000Hz). Participants were instructed to run at 3.5m/s ±5%. Velocity was monitored with the use of two photoelectric timing gates on either side of the force platform along the …

    unlv Repository record for Reliability of a Multisegment Foot Model in Shod Running (opens in a new tab) Download PDF for Reliability of a Multisegment Foot Model in Shod Running (opens in a new tab)

  19. Validation of smart device-based assessment of sit-to-stand

    … with an electro goniometer (eGONI) and force platform. Forty-two young adults (22.9 ± 2.9 years) performed three trials of a modified STS, which included five fast STS repetitions followed by fifteen successively deliberate decelerated repetitions to mimic fatigue in the elderly. A 5th …

    colostate Repository record for Validation of smart device-based assessment of sit-to-stand (opens in a new tab)

Page 1 of 10