Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"force-based design"”.

  1. Design of Controlled Rocking Heavy Timber Walls For Low-To-Moderate Seismic Hazard Regions

    … thesis proposes an adapted CRHTW in which the design and construction cost and complexity are reduced for low-to-moderate seismic hazard regions by removing supplemental energy dissipation and using cross-laminated timber (CLT) because of its positive economic and environmental potential in the …

    mcmaster Repository record for Design of Controlled Rocking Heavy Timber Walls For Low-To-Moderate Seismic Hazard Regions (opens in a new tab)

  2. Αντισεισμικός σχεδιασμός γεφυρών σκυροδέματος με βάση τις μετακινήσεις

    The majority of seismic design researchers/specialists concludes that displacement-based design methodologies reduce the uncertainty of the design process and probably lead to less expensive structures. The absence of a simple displacement-based seismic design procedure for bridges that will be …

    greece Repository record for Αντισεισμικός σχεδιασμός γεφυρών σκυροδέματος με βάση τις μετακινήσεις (opens in a new tab)

  3. Collapse Safety Assessment of Steel Multi-storey Buildings with Friction Sliding Braced Frames and Backup Moment Resisting Frames as a Dual System

    … the friction material used, development of the design procedure has been limited. Using a recently proposed force-based design method and considering detailed computational and modeling techniques, three types of seismic force resisting systems are presented herein: the bare Friction Sliding …

    concordia Download PDF for Collapse Safety Assessment of Steel Multi-storey Buildings with Friction Sliding Braced Frames and Backup Moment Resisting Frames as a Dual System (opens in a new tab)

  4. Seismic design and performance of steel moment resisting frame buildings designed using NBCC 2005

    … including Canada feel that a performance-based design approach should be used to ensure that the structure has adequate strength and deformation capacities. Although the National Building Code of Canada (NBCC 2005) is not yet a fully performance-based code, it presents an objective-based …

    concordia Download PDF for Seismic design and performance of steel moment resisting frame buildings designed using NBCC 2005 (opens in a new tab)

  5. Performance-based seismic analysis and design improvements of two precast concrete structural systems

    … test results for a five story test building. In designing both precast systems, it is shown that traditional force-based design approach results in significantly higher level of design base shear compared to direct displacement-based design approach. After observing satisfactory performance in …

    iastate Repository record for Performance-based seismic analysis and design improvements of two precast concrete structural systems (opens in a new tab)

  6. Seismic performance of multi-span RC bridge with irregular column heights

    … keep bridges safe and serviceable. Modern bridge design codes include seismic detailing in order to ensure ductile behavior, which was absent in the pre-1970 codes that made older bridges vulnerable during earthquakes. The main parameters effecting the performance of bridge (tie spacing, concrete …

    ubc Repository record for Seismic performance of multi-span RC bridge with irregular column heights (opens in a new tab) Download PDF for Seismic performance of multi-span RC bridge with irregular column heights (opens in a new tab)

  7. Performance based design and evaluation of reinforced concrete bridges

    Performance based design (PBD) has been deemed as one of the most promising design methods in the past few decades. It reduces the uncertainties underline the tradition force based design (FBD) and acts as an efficient communication tool between technical and non-technical people. Canadian Highway …

    ubc Repository record for Performance based design and evaluation of reinforced concrete bridges (opens in a new tab) Download PDF for Performance based design and evaluation of reinforced concrete bridges (opens in a new tab)

  8. Performance-based seismic design and evaluation of steel eccentrically braced frames with tubular links as bridge bents

    The latest release of the Canadian Highway Bridge Design Code (CHBDC), S6-14, incorporates performance-based design (PBD) provisions for bridges in Canada for the first time. CHBDC S6-14 establishes two different design approaches, with the PBD being the standard method of design and force-based …

    ubc Repository record for Performance-based seismic design and evaluation of steel eccentrically braced frames with tubular links as bridge bents (opens in a new tab) Download PDF for Performance-based seismic design and evaluation of steel eccentrically braced frames with tubular links as bridge bents (opens in a new tab)

  9. Critical seismic performance assessment of concrete bridge piers designed following Canadian Highway Bridge Design Code

    Performance-based design (PBD) method is gradually taking over the traditional force-based design (FBD) for designing bridges in North America. Considering the importance of bridge structures in the transportation network, quantitative performance criteria were adopted in Canadian Highway Bridge …

    ubc Repository record for Critical seismic performance assessment of concrete bridge piers designed following Canadian Highway Bridge Design Code (opens in a new tab) Download PDF for Critical seismic performance assessment of concrete bridge piers designed following Canadian Highway Bridge Design Code (opens in a new tab)

  10. Effects of Connections Detailing and Friction Dissipation Devices on the Seismic Response of a Hospital Steel Braced Frame Building

    Hospitals are post-disaster buildings designed to withstand seismic forces that are amplified with an importance factor of IE= 1.5. Their seismic force-resisting system (SFRS) should be designed with Rd> 2.0, while the interstorey drift at each floor is limited to 1.0%hs. Herein, Rd is the …

    concordia Download PDF for Effects of Connections Detailing and Friction Dissipation Devices on the Seismic Response of a Hospital Steel Braced Frame Building (opens in a new tab)

  11. Performance-based Seismic Design of Multi-Story Light-frame Wood Buildings using Adaptive Displacement-based Design Procedure

    … open floor plan in the first story. The current force-based design procedure, namely the Equivalent Lateral Force (ELF) procedure, does not explicitly consider the contribution of non-structural elements. This research (1) studied soft-story deficiency in light-frame wood buildings due to …

    clemson Repository record for Performance-based Seismic Design of Multi-Story Light-frame Wood Buildings using Adaptive Displacement-based Design Procedure (opens in a new tab)

  12. Seismic response factors of code-designed high-rise buildings using 3D non-linear analysis

    … recent initiatives and developments in building design provisions using performance-based design, practicing engineers frequently adopt force-based design approaches irrespective of the structural system or building irregularity. Modern seismic building codes adopt the concept of simplifying the …

    ubc Repository record for Seismic response factors of code-designed high-rise buildings using 3D non-linear analysis (opens in a new tab) Download PDF for Seismic response factors of code-designed high-rise buildings using 3D non-linear analysis (opens in a new tab)

  13. Performance-base seismic design of woodframe buildings using non-linear time history analysis

    Performance-based seismic design (PBSD) is a developing design methodology in the modern seismic design and research community and has already been applied to concrete and steel structures. However, the application to woodframe buildings, which represents the vast majority of the residential …

    colostate Repository record for Performance-base seismic design of woodframe buildings using non-linear time history analysis (opens in a new tab)

  14. Performance-based seismic retrofit (PBSR) methodology for multi-story buildings with full-scale experimental validation

    … of existing buildings. Many older buildings were designed prior to the implementation of modern seismic design codes. Although building codes have clearly evolved, the problem is still unresolved for older buildings that are code-deficient such as soft-story wood-frame buildings. Many retrofit …

    colostate Repository record for Performance-based seismic retrofit (PBSR) methodology for multi-story buildings with full-scale experimental validation (opens in a new tab)

  15. seismic performance of reinforced masonry shear walls with different masonry boundary element configurations

    Reinforced masonry (RM) shear walls are commonly used as a seismic force-resisting system (SFRS) in low and mid-rise buildings. Considerable progress has been made on the seismic performance of reinforced masonry shear walls with masonry boundary elements (RMSW+BEs). The integration of masonry …

    concordia Download PDF for seismic performance of reinforced masonry shear walls with different masonry boundary element configurations (opens in a new tab)