  1. Performance tests and cooling effect distribution of the V.P.I. forced draft cooling tower

    Test data of forced draft cooling towers is all too meager, and that available is, in many instances, incomplete. It is the opinion of the authors that putting cooling tower design on a rational basis can be brought about only by two methods. Either complete and intensive study of all existing …

    vt Repository record for Performance tests and cooling effect distribution of the V.P.I. forced draft cooling tower (opens in a new tab)

  2. Development and Test of a High Induction Permeameter with a Single Magnetizing Coil Surrounding the Pole Pieces and Specimen, and with Forced Draft Cooling

    This thesis is intended, primarily, as a description of the development of a piece of apparatus that is suitable for the determination of the magnetic properties of ferro-magnetic materials when subjected to very high magnetizing forces. It is believed that the permeameter described will be …

    marquette Repository record for Development and Test of a High Induction Permeameter with a Single Magnetizing Coil Surrounding the Pole Pieces and Specimen, and with Forced Draft Cooling (opens in a new tab)

  3. Design of a Combustion System Simulating Waste Heat Recovery from Diesel Engine Exhaust Gases

    A forced-draft laboratory combustion system simulating diesel engine exhaust gas volume flow rate and temperature conditions for waste energy recovery is analyzed and discussed. The system consists of a fan which supplies the air. The slightly compressed air is then ducted through a combustor where …

    odu Repository record for Design of a Combustion System Simulating Waste Heat Recovery from Diesel Engine Exhaust Gases (opens in a new tab)

  4. Quality of Tennessee-produced eggs

    … non insulated room (68 to 94 degrees F.) and a forced draft incubator (99 to 100 degrees F.). It was found that the shell eggs which had been treated in oil tended to retain their original quality better than did the water treated eggs.</p> <p>Chemicals (Sollax, Trend, and Vel) were used in …

    ut-knoxville Repository record for Quality of Tennessee-produced eggs (opens in a new tab)

  5. Development of Performance-Related Specifications for Asphalt Mixtures in Ontario

    … sensitive to the two methods of long-term aging (forced-draft oven aging at 85°C for 120 hours and forced-draft oven aging at 95°C for 72 hours) employed in this research. Moreover, the characterization of these asphalt mixtures by the I-FIT test revealed that forced-draft oven aging of I-FIT …

    waterloo Repository record for Development of Performance-Related Specifications for Asphalt Mixtures in Ontario (opens in a new tab)

  6. Excitation Emission Matrix Fluorescence Spectroscopy for analysis of Reactive Oxygen Species in Combustion Particulate Matter

    … from laboratory flame cookstove (natural and forced draft), and wildfire smoke (collected indoor and outdoor) are analyzed by EEM and the dithiothreitol (DTT) assay for ROS. While total integrated fluorescence of EEM does not provide clear patterns of association with ROS, with the …

    washington Repository record for Excitation Emission Matrix Fluorescence Spectroscopy for analysis of Reactive Oxygen Species in Combustion Particulate Matter (opens in a new tab)

  7. Atmospheric emissions from a gasifier wastewater fed cooling tower

    … of North Dakota Energy Research Center. This forced-draft counter flow tower was fed with minimally treated wastewater generated in slagging fixed-bed gasification of lignite, and operated at ten cycles of concentration. Test conditions were chosen to simulate those to be used in the …

    nodak Repository record for Atmospheric emissions from a gasifier wastewater fed cooling tower (opens in a new tab)

  8. Oxidative Aging of Binders with High Recycled Asphalt Materials

    … asphalt materials. A coordinated program of forced-draft oven aging experiments was conducted on eleven sorts of binder blends including three different types of base binders from TX, NH, and NV, two different types of recycled material (RAP/RAS), and two different types of recycling agents …

    unr Repository record for Oxidative Aging of Binders with High Recycled Asphalt Materials (opens in a new tab)

  9. Evaluation Of Oxidized Media Filtration Processes For The Treatment Of Hydrogen Sulfide In Groundwater

    … method identified in the Sulfide Rule (i.e. forced-draft aeration) would not adequately fit within the confines of the existing sites and would pose undue burden to neighboring residents. In addition, an effective sulfide treatment process was desired that offered a low profile, did not …

    ucf Repository record for Evaluation Of Oxidized Media Filtration Processes For The Treatment Of Hydrogen Sulfide In Groundwater (opens in a new tab)

  10. Návrh chladícího okruhu pro odvod tepla z kondenzátoru parní turbíny

    Diplomová práce se zabývá problematikou vyvedení zbytkového nízkopotenciálního tepla z kondenzátoru parní turbíny a jeho mařením. V teoretické části práce jsou nejdříve popsány různé druhy provedení kondenzátorů. Dále jsou popsány varianty chladících okruhů a možnosti jejich využití. Ve výpočtové …

    brno-tech Repository record for Návrh chladícího okruhu pro odvod tepla z kondenzátoru parní turbíny (opens in a new tab)

  11. Charakteristiky ventilátorových chladicích věží

    Tato diplomová práce pojednává o problematice ventilátorových chladicích věží. První část práce je rešeršní, zaměřuje se zejména na teorii chlazení a funkci ventilátorových chladicích věží obecně. Následuje kapitola zabývající se vodním hospodářstvím jaderné elektrárny Dukovany a specifikací …

    brno-tech Repository record for Charakteristiky ventilátorových chladicích věží (opens in a new tab)

  12. Mejora de la eficiencia energética de sistemas de climatización mediante enfriamiento evaporativo

    … the studied tower is classified as a mechanical forced draft, counterflow-parallel flow cooling tower. For this reason, the influence of the analysis method (Merkel and Poppe) and the arrangement of flow between the water and air streams (counterflow, parallel flow, and counterflow/parallel flow) …