Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 44 for “"four-electrode"”.
-
High Range Portable Bioimpedance Spectrometer with Four Electrode Analog Front End for Characterization of Mitochondria Bioenergetics
… The proposed bioimpedance spectrometer uses a four-point probe setup, i.e., two electrodes induce current while the other two electrodes pick up the voltage. This reduces the Maxwell-Wagner and counter ion polarization effects. We develop a portable bioimpedance spectrometer with adjustable …
-
Master Thesis
With a given fixed array of electrodes, a very large number of four electrode measurements can be made. However, most of the possible measurements are not linearly independent, indicating that a smaller number of measurements can be made in order to save time, and the results of other measurements …
-
Measurement and analysis of temporal variations of salinity in shallow water.
A four electrode conductivity instrument was developed to determine variations of conductivity in an ocean environment at a fixed point. A field experiment was conducted in Mission Bay, San Diego, California. Results indicate that the instrument functioned properly and accurately resolved …
-
Development of a CTD System for Environmental Measurements Using Novel PCB MEMS Fabrication Techniques
… and platinum. The basic principles of a planar four-electrode conductivity cell and the resistive temperature device are described here as well as the integration and the packaging of the microfabricated sensors for the underwater environment. Measurement results and successful field evaluation …
-
The Energy Analysis of Electrons Emitted from Localised Sites on Extended-Area High Voltage Electrodes
… from localised sites on broad-area high voltage electrodes under U.H.V. (~ 10-10 torr) conditions. Four electrode materials have been examined which are of interest in the industrial application of high voltage vacuum insulation. The energy spectra of these electron currents are shifted to low …
-
The validity of percent body fat estimates by Jackson & Pollock skinfold equation, near infrared, bioelectrical impedance and body mass index
… fat estimates by the Jackson & Pollock sum of four skinfold equation (JPSF), bioeletrical impedance (BIA), near infrared (NIR) and body mass index (BMI) when compared to the criterion method of underwater weighing (UWW). Skinfolds were measured at four sites, the triceps, ilium, abdomen and …
-
Complex electrical properties of shale as a function of frequency and water content
… have been used to span the frequency range: four-electrode setup for the low frequencies (5 Hz -13 MHz), and open-ended coaxial probe with network analyzer at the high end (20 MHz - 1,3 GHz), The probe technique is simple to use, potentially enabling field measurements of complex permittivity …
-
LAMOX šeimos deguonies kietųjų elektrolitų tyrimas plačiajuostės pilnutinės varžos spektroskopijos metodais /
… using impedance spectroscopy of two and four electrode methods in high temperature (300-900 °K) and frequency (10 Hz – 10 GHz) range examining electrical properties of three LAMOX family samples (La2Mo2O9, La2-xScxMo2O9 and La2-xSrxMo2O9 (x=0,05)). Determined values of activation energy …
-
Durability of Sodium Selective Super Ionic Conductors in Sodium and Chloride Containing Aqueous Environments at pH 2-11
… transport until failure was observed. Three and four electrode testing was performed to observe if any catastrophic failure would occur due to electrochemical exposure under the applied conditions. The three electrode set-up was a static solution set-up with 1M NaCl titrated to different pH for …
-
An Electroencephalographic (EEG) Study of Hemispheric Specialization Based Upon Average Evoked Response Methods and Power Spectral Density Methods of Signal Analysis
… passive reception of multiple presentations of four auditory stimuli (a pure tone, the vowel /a/, the stop consonant /b/, and a frequency and amplitude modulated tone sweep). Signal averaging was used to derive average evoked responses (AERs) to 28 presentations of each Phase I stimulus at four …
-
The impact of fine sensor spacing on complex tissue impedance spectra measurements in rabbit ventricular epicardium
… was to test the feasibility of using smaller electrodes with finer separations than sizes traditionally employed in cardiac electrophysiologic studies with whole hearts to resolve uCI spectra in terms of magnitude (|uCI|) and phase (
-
The effect of wettability, stress, and temperature on the saturation and cementation exponent of the Archie equation
… bead sample resistivity measurement by using the four-electrode technique, known to be immune from contact resistance effects. Glass beads were 180 to 250 μm in diameter and were cleaned with surfactants, rinsed with distilled water, and dried in an oven overnight. This treatment was performed to …
-
Autonomní měřič impedance
Tato práce se zabývá návrhem zařízení schopného autonomně měřit impedanci biologických materiálů. Cílem je vytvoření prototypu, který zpřístupní jednoduché webové rozhraní pro sběr dat z měření impedance v čase. Zařízení je schopné měřit impedanci nejenom pro určité frekvence, ale v celém …
-
Development of an electrical resistivity cone for groundwater contamination studies
… The module itself consists of an insulated four electrode array and is mounted behind a standard 15 sq cm piezo-cone (CPTU). Upon completion of the development phase the instrument was tested at four different sites. From field testing it was determined that the resistivity cone (RCPTU) was …
-
Investigation of carbon dioxide electrolysis reaction kinetics in a solid oxide electrolyzer
… zirconia sandwiched between two electrodes, is designed, manufactured and tested. The electrode/electrolyte interfacial polarization characteristics are investigated with the aid of the current interruption method using a four-electrode set-up. Activation overpotentials, which are …
-
Electrochemical study of corrosion phenomena in zirconium alloys
… materials are coupled. In this thesis research, four electrode pairs wre used to measure galvanic cirrent densities in the irradiation environment:Pt-Pt, Zircalloy (Zr-2), Inconel (X-750)-Pt, and Zr-2-X-750. To determine the changes in the coolant water conductivity dus to the presence of …
-
Electrochemical Characterization of Different Types of Waters and Their Effects on Cement Paste Hydration Properties Using the Electrochemical Impedance Spectroscopy, Vipulanandan Models, and Artificial Neural Network
… fitted across 20 Hz–300 kHz, extracting the four-parameter fingerprint {Rb, Rc, Cc, τ}. Dilution series at 25, 50 and 100 percent revealed dose–response regimes; the fingerprint resolved Extreme Ionic, Biogenic-Ionic, Organic and Freshwater groups. Cement paste was prepared at w/c = 0.40 with …
-
Fabrication and Measurement of LT-GaAs Photoconductive Antennas and Arrays
… LT-GaAs and BP devices have identical metallic electrodes, allowing for a comparison of emitted THz intensity and bandwidth. All PCAs have been measured using an open bench pulsed time-domain spectroscopy (TDS) system with a usable bandwidth from 0.1-4 THz, pumped with a 780nm Ti:Sapphire …
-
Direct writing of calcium phosphate/graphite nanocomposite film using laser induced graphitization of polyimides
… The processed powders were characterized using fourier transform infrared (FTIR) spectroscopy. FTIR results demonstrates that both CaO and eggshell transitions through a phase change when the material is synthesized with DHP. New C=O peak and ratio change change between Calcium carbonate and …
Page 1 of 3