Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 77 for “"four-storey"”.

  1. Seismic behaviour of steel plate shear walls by shake table testing

    … phase of the experimental program two single storey single bay specimens were tested cyclically to gain information on the general behaviour of the system and verify the adequacy of fabrication procedures. In the second phase, a single bay four-storey 25% scale specimen was tested under a …

    ubc Repository record for Seismic behaviour of steel plate shear walls by shake table testing (opens in a new tab) Download PDF for Seismic behaviour of steel plate shear walls by shake table testing (opens in a new tab)

  2. Behaviour of structures under fire conditions after earthquake events

    … handled numerically. The study is focused on a four-storey library building. It is emphasized that the study takes into account the damage that is induced due to earthquake to both structural and non-structural members. The basic objective is the assessment of both the fire behavior and the …

    greece Repository record for Behaviour of structures under fire conditions after earthquake events (opens in a new tab)

  3. The prospect of providing low-income medium density housing in developing countries : problems and opportunities with special reference to Cape Town, South Africa

    … medium-density housing (in the fonn of three- to four-storey walk-up blocks of flats) can be provided in central Cape Town and how these benefit from the existing bulk infrastructure. It further demonstrates how this housing type could be located and utilised to encourage a shift away from …

    cape-town Repository record for The prospect of providing low-income medium density housing in developing countries : problems and opportunities with special reference to Cape Town, South Africa (opens in a new tab)

  4. An Exploration of how Energy-Related Ecosystem Services Provided by Extensive Green Roofs in Alberta may be Quantified Using Life Cycle Assessment Tools

    … in a cooling load decrease of 5 427.42 kWh (four-storey building) and 12 883 kWh (thirteen-storey building). From an LCC perspective, the AEI's simple payback period exceeds its 20 year lifespan. The NPV and IRR are calculated as highly negative numbers which indicates that the financial cons …

    calgary Repository record for An Exploration of how Energy-Related Ecosystem Services Provided by Extensive Green Roofs in Alberta may be Quantified Using Life Cycle Assessment Tools (opens in a new tab)

  5. Effects of Strain Rate Dependency on Moment Resisting Frames with Reduced Beam Sections

    … grade 350W steel. Non-linear dynamic analyses on four-storey moderately ductile and limited ductility moment resisting frames with RBS for a suite of scaled ground motions have been carried out to investigate effects of material properties strain rate dependency on the response of the frame.

    carleton Repository record for Effects of Strain Rate Dependency on Moment Resisting Frames with Reduced Beam Sections (opens in a new tab)

  6. An accurate and computationally efficient three dimensional nonlinear model for the analysis of large-scale RC structures subjected to cyclic and dynamic loading conditions

    … modeling approach managed to simulate an entire four-storey RC building for 3 cyclic loading history tests based on the experimental data without any numerical problems. Finally, a numerical investigation has been performed for the efficiency of different RC wall retrofitting configurations of …

    greece Repository record for An accurate and computationally efficient three dimensional nonlinear model for the analysis of large-scale RC structures subjected to cyclic and dynamic loading conditions (opens in a new tab)

  7. An infill housing project in an existing Vancouver neighborhood

    … the issues and problems of the three to four storey main street mixed use residential /commercial building. In my project, I will focus on first, reinterpreting the boundary between the private spaces of the apartment and the public space of city, second, on improving the transition from …

    ubc Repository record for An infill housing project in an existing Vancouver neighborhood (opens in a new tab) Download PDF for An infill housing project in an existing Vancouver neighborhood (opens in a new tab)

  8. Modeling of Mechanical Behavior of Structural Masonry

    … are performed involving a reduced scale model of four storey masonry building subjected to seismic excitation. A linear dynamic analysis, in which the proposed macroscopic failure criterion is incorporated through the UMAT subroutine, is carried out to assess the plastic admissibility of the …

    mcmaster Repository record for Modeling of Mechanical Behavior of Structural Masonry (opens in a new tab)

  9. Mitigating torsional irregularity using cross laminated timber-reinforced concrete hybrid system

    … on buildings with torsional irregularity, a four-storey reinforced concrete (RC) structure with torsional irregularity is considered for Vancouver seismicity condition. SAP2000 software is used to conduct Linear Dynamic Analysis (LDA) and Non-Linear Time History Analysis (NLTHA) using eight …

    ubc Repository record for Mitigating torsional irregularity using cross laminated timber-reinforced concrete hybrid system (opens in a new tab) Download PDF for Mitigating torsional irregularity using cross laminated timber-reinforced concrete hybrid system (opens in a new tab)

  10. DLC: An interactive Museum of Technology & Digital Learning Centre for Winnipeg's exchange district

    … reuse of The Royal Albert Arm’s Hotel, a four-storey building located on 48 Albert Street in Winnipeg, Manitoba’s culturally rich Exchange District. Through the exploration of the site’s adaptive design potential, the structure’s existing interior has been transformed into an interactive …

    manitoba Repository record for DLC: An interactive Museum of Technology & Digital Learning Centre for Winnipeg's exchange district (opens in a new tab)

  11. Individualaus gyvenamojo namo interjero ir įrangos projektas /

    Designed interior of a four-storey building in central London - it is like a harmony between the old and new. This building - a classic Victorian built in the nineteenth century, the family home with original architecture and decoration. This house is a historical heritage that belongs to the …

    vilnius Repository record for Individualaus gyvenamojo namo interjero ir įrangos projektas / (opens in a new tab)

  12. Wind driven natural ventilation in courtyard and atrium-type buildings.

    … flows were measured in small replica models of four-storey courtyard and atrium buildings by means of small calibrated orifice plates. A parametric study of the geometry of the courtyard was made in isolation conditions, where the depth and breadth of the courtyard were systematically varied. …

    whiterose Download PDF for Wind driven natural ventilation in courtyard and atrium-type buildings. (opens in a new tab)

  13. Design, implementation and testing of a flexible, intelligent modem architecture for power line communications

    … of the modem architecture was performed in a four-storey industrial building which contains good, fair and poor quality communication links. Results for same phase and cross phase transmissions were collected and analyzed for two different test environments: (1) short length links of …

    ubc Repository record for Design, implementation and testing of a flexible, intelligent modem architecture for power line communications (opens in a new tab) Download PDF for Design, implementation and testing of a flexible, intelligent modem architecture for power line communications (opens in a new tab)

  14. Seismic response analysis of steel plate shear wall systems using detailed and simplified models

    … For seismic performance evaluation of a multi-storey building with SPSWs, detailed finite element models or a strip model can be used to represent the SPSW components. However, development and analysis of such models often require undesirable effort and excess time for high-to-medium rise …

    concordia Download PDF for Seismic response analysis of steel plate shear wall systems using detailed and simplified models (opens in a new tab)

  15. Seismic Response of Buildings that Utilise Unbonded Post-Tensioned Concrete Walls

    … to represent a previously tested full scale, four storey building with post-tensioned concrete walls. The building model accurately captured the measured response of the test building that was subjected to increasing intensities of earthquake motion on a tri-directional shake-table. To …

    auckland-ms Repository record for Seismic Response of Buildings that Utilise Unbonded Post-Tensioned Concrete Walls (opens in a new tab)

  16. The performance of steel beam to column gravity frame subassemblages with composite slabs in severe fires in multi-storey buildings

    … experimental data. Key components of a designed four-storey building were replicated and loaded until failure in ABAQUS following the recommended model establishment method. The simulation results revealed the interactive effect between different components. It was found that the interior column …

    auckland-ms Repository record for The performance of steel beam to column gravity frame subassemblages with composite slabs in severe fires in multi-storey buildings (opens in a new tab)

  17. The Fire in the Stone : The Life and Architectural Sculpture of Thomas Vallance Wran 1832-1891

    … and James Barnet. Wran's sculpture on two four-storey Pitt Street warehouses in 1973 was the first to base itself on indigenous Australian fauna in a carnival of wildlife that sparked interest in developing and Australian decoration among members of the new Institute of Architects, some …

    unsw Repository record for The Fire in the Stone : The Life and Architectural Sculpture of Thomas Vallance Wran 1832-1891 (opens in a new tab)

  18. Bytový dům, Brno - Slatina

    Záměrem investora je vybudovat v Brně v městské části Slatina na pozemku p.č. 2194/1 bytový dům pro 13 rodin. Stavba je řešena jako nepodsklepená čtyřpodlažní budova. Půdorys zastavění je tvaru T o max. rozměrech 16,82 x 30,32 m. Střecha je navržena jako jednoplášťová plochá střecha. Objekt bude …

    brno-tech Repository record for Bytový dům, Brno - Slatina (opens in a new tab)

Page 1 of 4