  1. Earthquake-Resistant T-Shaped Concrete Walls with High-Strength Reinforcement

    … Kansas to evaluate the influence of the uniform elongation ε_su and the fracture elongation ε_sf, in addition to f_y and f_t/f_y of high-strength reinforcement, on the deformation capacity of concrete walls subjected to reversed cyclic displacements. Two walls were tested, one with Grade 120 …

    ku Repository record for Earthquake-Resistant T-Shaped Concrete Walls with High-Strength Reinforcement (opens in a new tab)

  2. HIGH-STRENGTH STEEL BARS IN EARTHQUAKE-RESISTANT T-SHAPED CONCRETE WALLS

    … study also aimed to identify the minimum uniform elongation (ε_su) and fracture elongation (ε_sf) required of high-strength reinforcement for use in earthquake-resistant concrete structures. Test data are presented from four walls, T1 with conventional Grade 60 (420) reinforcement and T2, T3, and …

    ku Repository record for HIGH-STRENGTH STEEL BARS IN EARTHQUAKE-RESISTANT T-SHAPED CONCRETE WALLS (opens in a new tab)

  3. Critical seismic performance assessment of concrete bridge piers designed following Canadian Highway Bridge Design Code

    … ASTM grade steel of varying strength and fracture elongation in combination with different concrete strength. Performances of the designed bridge piers are evaluated for site-specific ground motion suits. Moreover, the impact of changing reinforcement strength on the designed bridge piers' …

    ubc Repository record for Critical seismic performance assessment of concrete bridge piers designed following Canadian Highway Bridge Design Code (opens in a new tab)

  4. Fracture of high-strength bars in concrete frame members under earthquake loads

    Fracture of longitudinal bars due to high-strain low-cycle fatigue is a critical failure mode in seismically detailed reinforced concrete frame members because it can lead to rapid strength loss and structural instability. The issue has recently attracted attention due to a national effort aimed at …

    texas Repository record for Fracture of high-strength bars in concrete frame members under earthquake loads (opens in a new tab)

  5. Tensile Strain Validation of Welded Wire Reinforcement

    There have been historical concerns regarding the ductility of welded wire reinforcement (WWR). Recent changes in ACI 318-19 now require all grades of A615 and Grade 100 A706 nonprestressed steel reinforcement to have a ratio of tensile strength to yield strength greater than 1.10 and 1.17 …

    byu Repository record for Tensile Strain Validation of Welded Wire Reinforcement (opens in a new tab)