Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 31 for “"frame connections"”.

  1. The fatigue performance of cross frame connections

    A new method of connecting cross-frames to bridge girders had been proposed to alleviate concerns with current design practices. This new, half-pipe detail needs to be examined for fatigue issues that may exist which would make it infeasible as a replacement candidate for the current bent-plate …

    texas Repository record for The fatigue performance of cross frame connections (opens in a new tab)

  2. Peak Connection Strength of Reduced Beam Section Moment Frame Connections

    … the design of reduced beam section (RBS) moment frame connections, the peak connection strength factor (𝐶𝑝𝑟) is used to estimate the expected maximum moment at the reduced section in the capacity-based design of moment-resisting frames. Current design provisions in AISC 358-22 define C𝑝𝑟 as the …

    byu Repository record for Peak Connection Strength of Reduced Beam Section Moment Frame Connections (opens in a new tab) Download PDF for Peak Connection Strength of Reduced Beam Section Moment Frame Connections (opens in a new tab)

  3. DIAGONAL ERECTION BRIDGING FOR OPEN WEB STEEL JOISTS WITH FLUSH FRAME CONNECTIONS

    … for the common case of joists with bearing seat connections. Flush frame connections for joists have been recently developed. These connections are similar in form to single-plate shear connections and can provide more restraint than bearing seat connections. With more restraint, less bracing may …

    ut-knoxville Repository record for DIAGONAL ERECTION BRIDGING FOR OPEN WEB STEEL JOISTS WITH FLUSH FRAME CONNECTIONS (opens in a new tab)

  4. Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates

    … and evaluation of a new special steel moment frame connection that employs replaceable buckling-restrained fuse plates that can enhance seismic performance and post-earthquake repairability. A total of eight unique specimens were tested on two series of beam-to-column subassemblies (W36 and …

    byu Repository record for Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates (opens in a new tab) Download PDF for Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates (opens in a new tab)

  5. Cyclic Behavior of Laterally Skewed Special Moment Frame Connections: Experimental Testing and System-Level Analyses

    Special moment frames (SMFs) are frequently used in high seismic areas for architecturally constrained designs. SMFs provide lateral system stiffness without the use of braces that often obstruct views and architectural features. Current American Institute of Steel Construction (ASIC) provisions …

    arkansas Repository record for Cyclic Behavior of Laterally Skewed Special Moment Frame Connections: Experimental Testing and System-Level Analyses (opens in a new tab)

  6. Development of a low damage steel frame building incorporating friction based braced and moment frame connections

    … benefits of using two types of friction-based connections in steel framed structures of seismically active regions, the Optimised Sliding Hinge Joint (OSHJ) for Moment Resisting Frames (MRF-OSHJ) and the Symmetric Friction Connection (SFC) with Belleville Springs (SFCBeSs) for Concentrically …

    auckland-ms Repository record for Development of a low damage steel frame building incorporating friction based braced and moment frame connections (opens in a new tab)

  7. APPLICATION OF ANGLES-WITH-PLATE RETROFIT IN REPAIRING DISTORTION-INDUCED FATIGUE DAMAGES IN STRINGER TO FLOORBEAM CONNECTIONS AND SKEWED GIRDER TO CROSS-FRAME CONNECTIONS

    … fatigue damage in straight girder to cross-frame connections (Bennett et al. 2014). The performance of the retrofit in this application motivated the researchers to investigate its performance in other types of connections susceptible to distortion-induced fatigue. This thesis consists of …

    ku Repository record for APPLICATION OF ANGLES-WITH-PLATE RETROFIT IN REPAIRING DISTORTION-INDUCED FATIGUE DAMAGES IN STRINGER TO FLOORBEAM CONNECTIONS AND SKEWED GIRDER TO CROSS-FRAME CONNECTIONS (opens in a new tab)

  8. Experimental Design and Preliminary Testing for Skewed Special Moment Frame Prequalification

    Special moment frames having specially detailed connections are common in high seismic regions, providing architectural flexibility for passageways and views without brace obstructions. In situations where the building framing layout requires deviation from typical rectangular framing, skew in the …

    arkansas Repository record for Experimental Design and Preliminary Testing for Skewed Special Moment Frame Prequalification (opens in a new tab)

  9. LOCATION AND CONFIGURATION OF REDUCED BEAM SECTION CONNECTION EFFECTS ON STRENGTH, STIFFNESS AND DUCTILITY OF MOMENT STEEL FRAMES

    Moment resistant frames are mainly used in resisting lateral loads in buildings. During the 1994 Northridge Earthquake, some of these moment steel frame connections could not undergo inelastic deformation which led to many structural damages. New connection systems were proposed and tested which …

    siu-theses Repository record for LOCATION AND CONFIGURATION OF REDUCED BEAM SECTION CONNECTION EFFECTS ON STRENGTH, STIFFNESS AND DUCTILITY OF MOMENT STEEL FRAMES (opens in a new tab)

  10. Analysis and validation of design guidelines proposed for precast concrete hybrid frame systems

    … verification tests, the precast hybrid frame concept has been developed for seismic applications over the past decade. During the course of this development, guidelines for designing hybrid frame connections have been proposed. The main objective of this study is to examine validation of …

    iastate Repository record for Analysis and validation of design guidelines proposed for precast concrete hybrid frame systems (opens in a new tab)

  11. Beam-column connection flexural behavior and seismic collapse performance of concentrically braced frames

    … the flexural behavior of beam-column connections with gusset plates and their ability to improve the seismic collapse performance of concentrically braced frames. Previous experimental and field observations demonstrated that reserve lateral force-resisting capacity due to the flexural …

    uiuc Repository record for Beam-column connection flexural behavior and seismic collapse performance of concentrically braced frames (opens in a new tab)

  12. Effect of Column Axial Load on Skewed SMF RBS Connection Demands

    … of an appropriate seismic steel system (braced frame, moment frame, shear wall, etc.) is often influenced by architectural considerations. Moment frame configurations offer the most architectural flexibility, but are limited by code prequalification requirements that limit the use of …

    arkansas Repository record for Effect of Column Axial Load on Skewed SMF RBS Connection Demands (opens in a new tab)

  13. Experimental Testing of Axially Loaded Fuse Plates Without Continuous Buckling Restraint

    … through strength and ductility. In moment frames, this ductility traditionally comes from inelastic deformation of beams. Moment frame connections move inelastic deformation away from the column and allow a plastic hinge to form in the beam. This plastic hinge prevents collapse but leaves …

    byu Repository record for Experimental Testing of Axially Loaded Fuse Plates Without Continuous Buckling Restraint (opens in a new tab) Download PDF for Experimental Testing of Axially Loaded Fuse Plates Without Continuous Buckling Restraint (opens in a new tab)

  14. Hybrid Steel Frames

    … steel systems: hybrid Buckling Restrained Braced Frames (BRBF) and hybrid steel Moment Frames (MF). The "hybrid" term for the BRBF system comes from the use of different steel material including carbon steel (A36), high-performance steel (HPS) and low yield point (LYP) steel. The hybridity of the …

    vt Repository record for Hybrid Steel Frames (opens in a new tab)

  15. NUMERICAL MODELING AND DESIGN OF LOW-RISE CONCENTRICALLY BRACED FRAMES WITH DOUBLE-PIN DISSIPATIVE CONNECTIONS

    Concentrically braced frames, CBFs, are the most popular systems used in seismic areas in Canada, due to their large stiffness. However, after braces buckle in compression, their stiffness is significantly reduced and their hysteresis response, displayed in terms of force-displacement, shows an …

    concordia Download PDF for NUMERICAL MODELING AND DESIGN OF LOW-RISE CONCENTRICALLY BRACED FRAMES WITH DOUBLE-PIN DISSIPATIVE CONNECTIONS (opens in a new tab)

  16. Seismic Fragility Assessment of Pre- and Post-Retrofit 1980s Concentrically Braced Frame Office Buildings in Moderate Seismic Zones

    … and Post-Retrofit 1980s Concentrically Braced Frame Office Buildings in Moderate Seismic Zones Ming Zheng Wang In the past decades, concentrically braced frames (CBFs) have been frequently employed as earthquake resistant systems due to their high stiffness and straightforward design. Over a …

    concordia Download PDF for Seismic Fragility Assessment of Pre- and Post-Retrofit 1980s Concentrically Braced Frame Office Buildings in Moderate Seismic Zones (opens in a new tab)

  17. Determining End & Edge Distance Criteria for Tenon Joints in Timber Structures

    <p>Traditionally, timber-frame connections use hardwood pegs to hold the main member within the joint. Currently the end and edge distance criteria for these connections have either been established by tradition or by an equivalent steel bolt diameter approximation. The object of this research is …

    ut-knoxville Repository record for Determining End & Edge Distance Criteria for Tenon Joints in Timber Structures (opens in a new tab)

  18. SYSTEM-LEVEL SEISMIC PERFORMANCE OF CONCENTRICALLY BRACED FRAMES WITH REPLACEABLE BRACE MODULES

    Concentrically braced frames with replaceable brace modules (RBMs) have the potential of improving the constructability of braced frames, mitigating the structural damage during earthquakes, and minimizing the time of post-earthquake repairs. To fill the gaps between the component-level performance …

    mcmaster Repository record for SYSTEM-LEVEL SEISMIC PERFORMANCE OF CONCENTRICALLY BRACED FRAMES WITH REPLACEABLE BRACE MODULES (opens in a new tab)

  19. An Investigation of Nailed Connection Performance in a Cyclic Humidity Environment

    The effect of cyclic moisture infiltration on connections in light-frame wood buildings has received limited research attention. Specifically, the connections between wood-based sheathing materials (OSB, plywood) and solid wood studs are of interest. A comprehensive understanding of connection …

    vt Repository record for An Investigation of Nailed Connection Performance in a Cyclic Humidity Environment (opens in a new tab)

  20. Experimental Evaluation of Replaceable Shear Fuse Moment Connections

    Steel special moment frames (SMFs) are known to be highly ductile seismic force- resisting systems. The performance of an SMF relies on the ability of the connections to accommodate large inelastic deformations. After the brittle failure of some steel moment frame connections during the 1994 …

    byu Repository record for Experimental Evaluation of Replaceable Shear Fuse Moment Connections (opens in a new tab) Download PDF for Experimental Evaluation of Replaceable Shear Fuse Moment Connections (opens in a new tab)