Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 31 for “"frame connections"”.
-
The fatigue performance of cross frame connections
A new method of connecting cross-frames to bridge girders had been proposed to alleviate concerns with current design practices. This new, half-pipe detail needs to be examined for fatigue issues that may exist which would make it infeasible as a replacement candidate for the current bent-plate …
-
Peak Connection Strength of Reduced Beam Section Moment Frame Connections
… the design of reduced beam section (RBS) moment frame connections, the peak connection strength factor (𝐶𝑝𝑟) is used to estimate the expected maximum moment at the reduced section in the capacity-based design of moment-resisting frames. Current design provisions in AISC 358-22 define C𝑝𝑟 as the …
-
DIAGONAL ERECTION BRIDGING FOR OPEN WEB STEEL JOISTS WITH FLUSH FRAME CONNECTIONS
… for the common case of joists with bearing seat connections. Flush frame connections for joists have been recently developed. These connections are similar in form to single-plate shear connections and can provide more restraint than bearing seat connections. With more restraint, less bracing may …
-
Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates
… and evaluation of a new special steel moment frame connection that employs replaceable buckling-restrained fuse plates that can enhance seismic performance and post-earthquake repairability. A total of eight unique specimens were tested on two series of beam-to-column subassemblies (W36 and …
-
Cyclic Behavior of Laterally Skewed Special Moment Frame Connections: Experimental Testing and System-Level Analyses
Special moment frames (SMFs) are frequently used in high seismic areas for architecturally constrained designs. SMFs provide lateral system stiffness without the use of braces that often obstruct views and architectural features. Current American Institute of Steel Construction (ASIC) provisions …
-
Development of a low damage steel frame building incorporating friction based braced and moment frame connections
… benefits of using two types of friction-based connections in steel framed structures of seismically active regions, the Optimised Sliding Hinge Joint (OSHJ) for Moment Resisting Frames (MRF-OSHJ) and the Symmetric Friction Connection (SFC) with Belleville Springs (SFCBeSs) for Concentrically …
-
APPLICATION OF ANGLES-WITH-PLATE RETROFIT IN REPAIRING DISTORTION-INDUCED FATIGUE DAMAGES IN STRINGER TO FLOORBEAM CONNECTIONS AND SKEWED GIRDER TO CROSS-FRAME CONNECTIONS
… fatigue damage in straight girder to cross-frame connections (Bennett et al. 2014). The performance of the retrofit in this application motivated the researchers to investigate its performance in other types of connections susceptible to distortion-induced fatigue. This thesis consists of …
-
Experimental Design and Preliminary Testing for Skewed Special Moment Frame Prequalification
Special moment frames having specially detailed connections are common in high seismic regions, providing architectural flexibility for passageways and views without brace obstructions. In situations where the building framing layout requires deviation from typical rectangular framing, skew in the …
-
LOCATION AND CONFIGURATION OF REDUCED BEAM SECTION CONNECTION EFFECTS ON STRENGTH, STIFFNESS AND DUCTILITY OF MOMENT STEEL FRAMES
Moment resistant frames are mainly used in resisting lateral loads in buildings. During the 1994 Northridge Earthquake, some of these moment steel frame connections could not undergo inelastic deformation which led to many structural damages. New connection systems were proposed and tested which …
-
Analysis and validation of design guidelines proposed for precast concrete hybrid frame systems
… verification tests, the precast hybrid frame concept has been developed for seismic applications over the past decade. During the course of this development, guidelines for designing hybrid frame connections have been proposed. The main objective of this study is to examine validation of …
-
Beam-column connection flexural behavior and seismic collapse performance of concentrically braced frames
… the flexural behavior of beam-column connections with gusset plates and their ability to improve the seismic collapse performance of concentrically braced frames. Previous experimental and field observations demonstrated that reserve lateral force-resisting capacity due to the flexural …
-
Effect of Column Axial Load on Skewed SMF RBS Connection Demands
… of an appropriate seismic steel system (braced frame, moment frame, shear wall, etc.) is often influenced by architectural considerations. Moment frame configurations offer the most architectural flexibility, but are limited by code prequalification requirements that limit the use of …
-
Experimental Testing of Axially Loaded Fuse Plates Without Continuous Buckling Restraint
… through strength and ductility. In moment frames, this ductility traditionally comes from inelastic deformation of beams. Moment frame connections move inelastic deformation away from the column and allow a plastic hinge to form in the beam. This plastic hinge prevents collapse but leaves …
-
Hybrid Steel Frames
… steel systems: hybrid Buckling Restrained Braced Frames (BRBF) and hybrid steel Moment Frames (MF). The "hybrid" term for the BRBF system comes from the use of different steel material including carbon steel (A36), high-performance steel (HPS) and low yield point (LYP) steel. The hybridity of the …
-
NUMERICAL MODELING AND DESIGN OF LOW-RISE CONCENTRICALLY BRACED FRAMES WITH DOUBLE-PIN DISSIPATIVE CONNECTIONS
Concentrically braced frames, CBFs, are the most popular systems used in seismic areas in Canada, due to their large stiffness. However, after braces buckle in compression, their stiffness is significantly reduced and their hysteresis response, displayed in terms of force-displacement, shows an …
-
Seismic Fragility Assessment of Pre- and Post-Retrofit 1980s Concentrically Braced Frame Office Buildings in Moderate Seismic Zones
… and Post-Retrofit 1980s Concentrically Braced Frame Office Buildings in Moderate Seismic Zones Ming Zheng Wang In the past decades, concentrically braced frames (CBFs) have been frequently employed as earthquake resistant systems due to their high stiffness and straightforward design. Over a …
-
Determining End & Edge Distance Criteria for Tenon Joints in Timber Structures
<p>Traditionally, timber-frame connections use hardwood pegs to hold the main member within the joint. Currently the end and edge distance criteria for these connections have either been established by tradition or by an equivalent steel bolt diameter approximation. The object of this research is …
-
SYSTEM-LEVEL SEISMIC PERFORMANCE OF CONCENTRICALLY BRACED FRAMES WITH REPLACEABLE BRACE MODULES
Concentrically braced frames with replaceable brace modules (RBMs) have the potential of improving the constructability of braced frames, mitigating the structural damage during earthquakes, and minimizing the time of post-earthquake repairs. To fill the gaps between the component-level performance …
-
An Investigation of Nailed Connection Performance in a Cyclic Humidity Environment
The effect of cyclic moisture infiltration on connections in light-frame wood buildings has received limited research attention. Specifically, the connections between wood-based sheathing materials (OSB, plywood) and solid wood studs are of interest. A comprehensive understanding of connection …
-
Experimental Evaluation of Replaceable Shear Fuse Moment Connections
Steel special moment frames (SMFs) are known to be highly ductile seismic force- resisting systems. The performance of an SMF relies on the ability of the connections to accommodate large inelastic deformations. After the brittle failure of some steel moment frame connections during the 1994 …
Page 1 of 2