Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 32 for “"free cooling"”.
-
Free cooling potential for data centers in Brazil
… Neste contexto, o resfriamento natural (free cooling) surge como uma solução eficaz a fim de reduzir o consumo de energia nestas instalações. Este trabalho propõe critérios para avaliar o potencial de resfriamento natural para data centers no Brasil, considerando economizadores à ar e à …
-
Development of an Improved PCM-to-Air Heat Exchanger for Building Envelopes - Advancement to Free Cooling Applications
… thermal energy storage systems toward reducing cooling load has been increased in recent years. In this study, the utilization of phase change materials (PCMs) has been comprehensively discussed for building free cooling applications. The potential and limitations of using PCM-to-Air Heat …
-
Space Cooling using Active Chilled Beams and Free Cooling by Outdoor Air: A Performance Assessment Based on Simulations in IDA ICE
Comfort cooling is increasingly vital, particularly with rising ambient temperatures and growing demands for indoor environmental quality, significantly impacting a building’s energy performance. Consequently, there is a need to reduce purchased cooling through the utilization of ambient free …
-
Energieffektiva livsmedelsbutiker - en studie av förutsättningar för användning av frikyla.
… presents a study of how the feasibility of using free-cooling in a supermarket changes when more efficient display-cases are being used, Free-eooling means the use of natural low temperatures , i .e, cooling with free heat sinks in the nature like cold ambient air. The study has been perfonned for …
-
Evaluation of Energy and Airflow Performance of Data Centers with Centralized Thermosiphon
… the IT equipment all year round. Conventional cooling energy saving strategy is to utilize outdoor air directly to cool the IT equipment when outdoor temperature is lower, which known as direct airside free cooling. However, the main concerns about this approach is the breakdown of IT equipment …
-
Commercial Building Energy Performance - Room cooling principles and hydronic cooling system temperatures
… property owners. This thesis aims to map typical cooling demands in a commercial building and explore the possibilities, limitations and basic energy demands associated with different room cooling principles. Another aim is to investigate the possibilities of improving hydronic cooling system …
-
Energy saving opportunities in residential buildings: insights from technological and building energy code perspectives
… winter climatic conditions; while, the building cooling energy use can be increased due to the undesired thermal recovery occurring in the HRV during the cooling season. The second study investigates the free cooling potential of outside air in various Canadian cities. A series of thermal models …
-
Combating urban heat islands : assessing the potential of open-loop geothermal heat pump systems in Canada
… hold significant potential for sustainable space cooling solutions to help address the growing issue of urban heat islands, yet their suitability has remained underexplored. This study presents an assessment of urban aquifer suitability for cooling with groundwater heat pump (GWHP) systems in 10 …
-
Snížení energetické náročnosti výrobního areálu
… Pro chlazení jsou možnosti volného chlazení (free cooling) včetně návrhu suchého chladiče a jeho zařazení do chladícího okruhu. V poslední části je návrh nové světelné soustavy s využitím LED svítidel.
-
Expanding the applicability of residential economizers through HVAC control strategies
… the range of climates and conditions in which free cooling from an economizer can replace air conditioning power consumption in residential applications. To explore this issue, we first discretize a simple building model in space and in time. We then solve the associated energy and mass …
-
MODELING CONTROL STRATEGIES OF A HIGH-PERFORMANCE ENERGY RECOVERY VENTILATOR IN NIST'S NET ZERO ENERGY RESIDENTIAL TEST FACILITY
… stale air streams. This bypass mode allows for free cooling in the shoulder seasons by using cooler outdoor air to cool the inside of the building. To test the energy savings potential for temperature-based and enthalpic-free cooling control schemes, a TRNSYS model was updated and tuned to …
-
Simulation and Performance Analysis of Active PCM-Heat Exchanger to Optimize Building Operation
… a simulation case study of The PCM-HX for free-cooling purposes. Results show that in the present case-study, 14% reduction in energy consumption and 24 % reduction in cooling power fluctuation (W) during daytime could be achieved using the PCM heat exchanger (PCM-HX) for free cooling. The …
-
Impacts of increased outdoor air flow rates on annual HVAC energy costs in office environment
… examines the relationship between heating and cooling load, and the associated energy consumption and energy costs with different HVAC system configurations. The influence of the HVAC system using economizer, heat exchanger or both, in CAV and VAV configuration, has been studied in five …
-
Definition and validation of a simplified multizone dynamic building model connected to heating system and HVAC unit.
… air quality level, the thermal comfort when free-cooling is performed, and the building energy balance.The building lumped model is connected to equipments including heating andcooling terminal units as well as water pipes, air ducts, heating and cooling plants. The equipments models are …
-
Membrane-Based Energy Recovery Ventilator Coupled with Thermal Energy Storage Using Phase Change Material for Efficient Building Energy Savings
… the energy consumption of the HVAC system for cooling and heating the spaces inside the building. The membranes were stacked parallel to each other forming adjacent channels in a counter-flow arrangement for OFA and EA streams. Heat and moisture is diffused through the membrane core. Flat-plate …
-
Measurement, Analysis, and Modeling of Non-Isothermal Low-Velocity Displacement Ventilation Jets
… higher supply air temperature and opportunity of free cooling. A frequent complaint associated with displacement ventilation is however the draft discomfort caused by the colder air movement at foot level, and the local discomfort due to an excessive temperature difference between head and ankle. …
-
Computer simulated studies for energy-efficient operation of HVAC equipment
… to describe the system fans, heating coils, cooling coils, heat exchangers and load calculations.</p> <p>Studies of the single-duct air handler show that it is advantageous to apply year—round continuous operating control strategies and therefore eliminate the need for operator assistance in …
-
A New Bayesian Inference Calibration Platform for Building Energy and Environment Predictions
… of ventilation performance and predictions of free cooling load. The conclusion includes a summary of the contributions of this thesis and suggestions for future work.
-
Heating, ventilation and air conditioning system optimization: a study of the effect of climate, building design, system selection and control strategy on the energy consumption of a typical office building in London and Athens
… system, mainly due to the exploitation of the free cooling capacity of the outdoor air. The difference in carbon emissions between the two systems drops when both of them are simulated for the Athens as opposed to the London typical weather conditions. It has been found that it is possible to …
Page 1 of 2