Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 50 for “"fringe field"”

  1. New fringe-field capacitive sensors.

    ottawa-retro Repository record for New fringe-field capacitive sensors. (opens in a new tab)

  2. Soil permittivity determination using a fringe field capacitor

    … into three sections: (1) design of the fringe field dielectric sensor, (2) development of instrumentation and equations required to calculate permittivity parameters and (3) testing of the system in soil. A double-cylinder configuration was selected and results from solving Laplace's …

    nebraska Repository record for Soil permittivity determination using a fringe field capacitor (opens in a new tab)

  3. Fringe Field Corrections in nvCPD Probe Tip Applications

    … and an analytical model was developed, including fringe electrical fields, that predicts the shape of the nvCPD probe signal as a function of probe tip geometry, work function variation, and experimental parameters. Probe tips were constructed with varying geometric properties and experiments …

    gatech Repository record for Fringe Field Corrections in nvCPD Probe Tip Applications (opens in a new tab)

  4. TUNABLE LIQUID CRYSTAL BEAM STEERING DEVICE BASED ON PANCHARATNAM PHASE IN FRINGE FIELD SWITCHING MODE

    In this dissertation, a novel approach to a liquid crystal electro-optical device for light beam steering is examined. The proposed apparatus, so called "FFS-PPD", with fast switching variable phase and tunability is successfully developed for the first time. The device was first designed, analyzed …

    ohiolink Repository record for TUNABLE LIQUID CRYSTAL BEAM STEERING DEVICE BASED ON PANCHARATNAM PHASE IN FRINGE FIELD SWITCHING MODE (opens in a new tab)

  5. Calibration of the chaos spectrometer for small scattering angles

    … The out-of-plane information from WC4 requires a fringe field correction, because it lies outside the uniform magnetic field of CHAOS. The fringe field of CHAOS acts like a lens, in that it has a slight focusing effect on charged particles. The fringe field correction moves the WC4 (x,y,z) data …

    ubc Repository record for Calibration of the chaos spectrometer for small scattering angles (opens in a new tab)

  6. Compatibility of X-ray Tubes with Magnetic Resonance Imaging Scanners for Aortic Valve Replacement

    … of a rotating-anode x-ray tube in the magnetic fringe field of a 1.5 T MRI scanner was investigated. A rotating-anode x-ray tube provides the fluoroscopy and angiography needed for PAVR. The magnetic fringe field can affect the ability of the x-ray tube to dissipate heat. It was shown that the …

    toronto-retro Repository record for Compatibility of X-ray Tubes with Magnetic Resonance Imaging Scanners for Aortic Valve Replacement (opens in a new tab)

  7. Transmission Characteristics of the Quadrupole Mass Spectrometer

    … restrict the applicability of portable MS for in-field applications. Sensitivity is influenced by the three-dimensional (3D) fringe field effects on the ion transmission characteristics of the Quadrupole Mass Filter (QMF). There is a requirement for a greater understanding of these effects. …

    liverpool Repository record for Transmission Characteristics of the Quadrupole Mass Spectrometer (opens in a new tab) Embargoed until 2525-05-02

  8. NEW DIRECTIONS IN THE DESIGN OF MRI GRADIENT COILS

    … The principal work is on better shielding for fringe field reduction. Fringe fields from gradient coils produce eddy currents in surrounding metal structures. Such eddy currents can degrade image quality and lead to acoustic noise. Our new shielded gradient coil designs that feature the …

    ohiolink Repository record for NEW DIRECTIONS IN THE DESIGN OF MRI GRADIENT COILS (opens in a new tab)

  9. Control of Disclinations and Walls in New Types of Display Devices

    … mechanism is based on a one-dimensional director field study, which does not allow the existence of a modulation of the director field in the plane of the cell, or for a disclination line. In this dissertation, we study the phenomenon of a fast bulk transition through a two-dimensional dynamic …

    ohiolink Repository record for Control of Disclinations and Walls in New Types of Display Devices (opens in a new tab)

  10. An Interferometric Study Of Coupled Convective Heat Transfer In A Horizontal Flat Plate Enclosure

    … qualitative as well as quantitative temperature field visualization of the fluid layers within the enclosure between the hot bottom plate and cold top plate boundaries of the collector, and the coupling effect of natural and forced convection on the cold plate.;The horizontal rectangular …

    uwo Repository record for An Interferometric Study Of Coupled Convective Heat Transfer In A Horizontal Flat Plate Enclosure (opens in a new tab)

  11. Liquid level measurement using a coplanar transmission line

    … the electrical component of the electromagnetic fringe field, setup between its inner conductor, and the surrounding ground plane. The line is effectively a sharply tuned resonator, incorporated as the frequency controlling element of an electronic oscillator. The output frequency falls as a …

    cape-town Repository record for Liquid level measurement using a coplanar transmission line (opens in a new tab)

  12. Inner Triplet Quadrupole Fringe Fields in the High Luminosity Large Hadron Collider

    … between poles means that the tapering of the field at the end of the magnets is more pronounced. These tapering fields are known as fringe fields, and they have a nonlinear dynamical effect on the beam. This could mean a potentially disastrous effect on the beam performance. The goal of this …

    liverpool Repository record for Inner Triplet Quadrupole Fringe Fields in the High Luminosity Large Hadron Collider (opens in a new tab)

  13. Polymer Stabilized Liquid Crystals: Topology-Mediated Electro-Optical Behavior And Applications

    … and fast response time have been applied to the fringe-field switching (FFS) system. The concentration of reactive monomer on the electro-optical behavior of the FFS cells is optimized. The outstanding electro-optical results and mechanism of increase in surface anchoring strength are …

    ohiolink Repository record for Polymer Stabilized Liquid Crystals: Topology-Mediated Electro-Optical Behavior And Applications (opens in a new tab)

  14. Magnetic field measurements in quadrupole magnets

    Magnetic field measurements have been made on a 4" diameter aperture beam-line quadrupole magnet. One method of measurement uses a rotating coil with a narrow bandwidth wave analyzer and the other a Hall plate survey system interfaced to an on-line mini-computer. The measurements are analyzed to …

    uvic Repository record for Magnetic field measurements in quadrupole magnets (opens in a new tab)

  15. Beam injection and Matching Studies in the University of Maryland Electron Ring

    … crucial. Injection is done through a quadrupole fringe field, making it more challenging. Careful injection of a matched beam will also minimize emittance growth and halo formation around the ring. In this thesis, experimental results from the injection, matching, and transport of a space charge …

    maryland Repository record for Beam injection and Matching Studies in the University of Maryland Electron Ring (opens in a new tab)

  16. Design and characterization of magnetic systems in race-track microtrons

    … of Nuclear Physics (SINP). The magnetic field in the designed magnets is generated by rare earth permanent magnet (REPM) materials. This allows to get quite compact magnetic systems compatible with high vacuum environment. In the thesis the design and magnetic properties characterization …

    barcelona Repository record for Design and characterization of magnetic systems in race-track microtrons (opens in a new tab)

  17. Studies of the effects of non-linear materials in the CREX septum magnet using finite element analysis simulations

    … the equipment, the septum magnet needs to meet field requirements suitable for CREX. As the magnet is iron-dominated the field response is non-linear at sufficiently high current. This is of particular concern for CREX which is run at a beam energy more than double that of PREX-2 and requires a …

    manitoba Repository record for Studies of the effects of non-linear materials in the CREX septum magnet using finite element analysis simulations (opens in a new tab)

Page 1 of 3