The Design and Characterization of a Multiple Pinhole Collimator and Its Applications in Biopharmaceutics
… function at 8 cm from the collimator had a full-width-half-maximum of 8.5 mm and the depth resolution was 2 cm at 7.5 cm from the collimator. The geometric distortion of images caused by multi-pinhole collimation was also investigated. It was concluded that tablet disintegration can only be …
-
Ultrafast ultraviolet : hollow capillary fibres for time-resolved photoelectron imaging
… with the extremely short time resolution (10 fs full-width-half-maximum at 250 nm central wavelength) offered by a novel hollow capillary fibre (HCF)-based resonant dispersive wave (RDW) scheme. This method was shown to be extraordinarily powerful for unravelling ultrafast excited state excess …
-
Fully Integrated CMOS-Compatible Photodetector with Intrinsic Gain and Red-Green-Blue Color Selectivity
… into useful photocurrent. Here we demonstrate a fully integrated, metal-semiconductor-metal (MSM) photodetector and plasmonic color filter fabricated entirely from Aluminum and silicon designed to detect light in selected wavelength bands across the visible spectrum. The device produces …
-
EFFECT OF Si02, TOTAL FeO, Fe3+/Fe2+, AND ALKALIS IN BASALTIC GLASSES ON MID-INFRARED SPECTRA
… wavenumbers as SÌO2 content increases. The full width half maximum of the Si-0 feature decreases as total alkali content increases. FeOtotai and Fe /Fe have no effect on the location or shape of the Si-0 feature. These observations indicate that mid-infrared spectra of basaltic glasses may …
-
Demonstration of a new gamma spectrometer designed for radiometric surveying with an unmanned aircraft system
… was demonstrated. The ARDUO's properties of the full-width half maximum energy resolution, linearity, gain stability, intrinsic photopeak efficiency, sheet source sensitivity and directional response were characterized in laboratory experiments. Small-scale trials were conducted over a single …
-
Design and Implementation of a Complex-conjugate Shaper and Baseline Restorer for a Silicon-based Neutron Detector Front-end
… near 20 nanoseconds. The output signal has a full-width half-maximum (FWHM) of around 270 nanoseconds and a settling time of 0.6 microseconds, allowing for a 1- microsecond pulse-pair resolution. The shaper and baseline restorer have selectable polarity to accommodate input pulses of both …
-
Azimuthal dependence of the atmospheric gamma-ray background
… of the same material. The instrument had a beam width of 15° full width half maximum. Results are consistent with an observed sinusoidal perturbation of the average background count rate between 56 KeV and 375 KeV of the form R = B[1 + (.188 ± .33)sin(Az - (12° ± 22°))] where R is the photon …
-
Measurement of the perseus cluster gamma-ray spectrum
… of the same material. The instrument had a beam width of 13° full width half maximum. The results obtained show that NGC 1275 in particular and the Perseus cluster in general do not constitute a detectable gamma-ray source. A series of upper limits to the flux in the 56 keV to 12.4 MeV energy …
-
An Investigation of Electrode Nanostructuring in Energy Storage Applications
… metal anodes, recently-isolated PNRs were successfully applied as an anode material with carbon black. The electrodes achieved reversible lithiation capacities of up to 160 mAh g–1 with limited capacity degradation after 80 cycles. Pioneering total neutron scattering studies were completed on hard …
-
Gamma-ray emission and absorption in the inner few parsecs of the Galactic Centre
… MAGIC, and CTA. Current telescopes, limited by a full-width half-maximum of 5 arcminutes, struggle to pinpoint the nature of gamma-ray sources amidst the Galactic Centre’s complexity. UV/visible observations are also compromised due to dust absorption and infrared re-emission. However, this study …
-
Synthesis and Characterization of Functionalized Surfaces for Rapid Determination of Alpha Particle Emitting Radionuclides
… self-absorption was kept to a minimum and full width half maximum values were commonly seen between 17 keV and 39 keV at 5.6 MeV. However, the requirement for this thin layer causes a reduction in uptake efficiency due to the low mass of GO on the substrate.
-
Growing oxide thin films in a low-energy electron microscope
… growth by monitoring the intensity and the full-width-half-maximum (FWHM) of the specular diffracted beam at various energies. For layer-by-layer growth, we find the anticipated intensity peaks at the completion of each layer, and an oscillatory FWHM with the maximum at half-layer coverage. …
-
Comparison of multi-cavity arrays for on-chip WDM applications
… transmission, group delay, quality factor, and full width half maximum (FWHM) characteristics. Identical transmission characteristic is observed for both systems whereas group delay values of classical EIT is two times higher than the cavity-QD EIT surprisingly. Then, single QD embedded …
-
Mapping Organic Molecular Motions with RF Compressed Femtosecond Electron Diffraction
… ponderomotive scattering technique is used to fully characterize the temporal characteristics of the high brightness electron pulses. A minimum temporal instrument response of 420 femtoseconds (full-width-half-maximum) for 200 femtocoulomb electron bunches is reported. The instrument response …
-
Tailoring angular and spectral behaviour in perovskite optoelectronic devices
… electroluminescence with an angular full-width half-maximum of 36.6°, significantly improved from isotropic unconfined devices, and a spectral narrowing with a full-width half-maximum of 12.1 nm. The versatility of this design allows it to be tuned for wide angle emission, making it a …
-
Spectroscopic studies of hot, luminous stars
… are investigated, and calibrations between CCF full-width half-maximum and rotational velocity are derived. These calibrations are used to find rotational velocities for over 700 stars.
-
The Design and Fabrication of a Microfluidic Reactor for Synthesis of Cadmium Selenide Quantum Dots Using Silicon and Glass Substrates
… The QD size was characterized by fluorescence full-width-half-maximum (FWHM), which is directly proportional to size distribution. The FWHM of the QDs synthesized was 38 nm, with a peak wavelength of 492 nm. By controlling combinations of pump rate and channel length, a range of QD sizes was …
-
Shell middens - Unlocking hidden archaeological information using Raman spectroscopy
… to obtain the peak position, amplitude and full width half maximum (FWHM) parameters, which were then compared between modern and ancient Conomurex fasciatus and Nucella sp. shells to obtain markers of diagenesis. Modern Conomurex fasciatus shells were heated at different temperatures and …
-
Hybrid Quantum Well/Quantum Dot Structure for Broad Spectral Bandwidth Emitters
… from both the QW and the QDs resulted in a full width half maximum (FWHM) of 250nm being demonstrated. In Chapter 4, experimental results on the modal gain and lasing characteristic of hybrid QW/QD laser are described. Due to the contribution from the QD ground state and first excited state, …
-
Transition region spectroscopy of dialkali halides: Sodium(2)chloride and sodium(2) + atomic fluorine going to sodium fluoride + sodium
… region simultaneously, images atomic lines to a full-width-half-maximum (fwhm) of 2 nm, has a photocathode quantum efficiency of 3.1% at 800 nm, and exhibits only 36 counts per second dark current.