Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 119 for “"full-scale test"”.
-
Full-scale test of an aboveground storm shelter
Not available
-
Full Scale Test Case For Sailing Yacht Performance
… investigates the possibilities of producing a full scale test case of the performance of sailing yachts. With such a test case, it is believed that instantaneous and absolute performance of sailing yacht evolving in real conditions can be investigated. An out-put of this study is the ability to …
-
Flow visualization techniques for full-scale test objects in a wind tunnel: Evaluation of a novel flow visualization technique
… low complexity. ProCap measurements around a full-scale car in a commercial wind tunnel are compared against an existing pressure-based traversegear system and CFD simulations. The findings show that ProCap is not sufficiently accurate or consistent for CFD method validation, but can be a …
-
A Comparison of Predicted Brace Loads in Temporary Retaining Structures and Observed Brace Loads in Two Full Scale Test Sections
… the construction schedule, the geotechnical testing apparatus and instrumentation, and the data produced from the geotechnical instrumentation program. In this thesis, several theoretical approaches available for estimating the strut loads in braced excavations were examined and used to …
-
Fatigue life determination of a damage-tolerant composite airframe
… proposed in this research extends the current full-scale test approach based on the life factor and the load enhancement factor, and provides information necessary to define inspection intervals for composite structures by studying the effects of extremely improbable, high-energy impact damage. …
-
Some physical characteristics and exposure loss estimates of pea vine silage in a horizontal silo
… were investigated by field observation on a full scale test silo. Density, dry matter, permeability and some proximate analyses of the silage are tabulated. Observed dry matter losses in order of magnitude are fermentation losses, sub surface losses, surface losses, and losses in runoff and …
-
Assessment of Local Strains in Geomembranes at Gravel Indentations
… on how the strains are calculated and what testing methods are used to obtain the deformed shape of the geomembrane. This involved the use of established test methods and apparatuses but using a 3D laser scanner to obtain the deformed shape and a recently developed theoretical technique to …
-
Behaviour of ultra-high performance concrete as a joint-fill material for precast bridge deck panels subjected to negative bending
… deck panels subjected to negative bending. Two full-scale test specimens were constructed. The transverse joints between the panels, the shear pockets, and the deck haunches were all filled with UHPC. A total of four tests were performed including two static tests to failure and two fatigue …
-
Analysis and Design of a New Generation GFRP Wind Turbine Tower
… reinforced polymer (GFRP) wind turbine tower for full scale prototype testing. The study includes the finite element analyses of different tower section configurations, the parametrical study of different variables, the selection of appropriate configuration and dimensions, and the finalization of …
-
A linear programming model for naval officer distribution
… the technique, The author recommends that a full scale test problem be constructed with an activity configuration which resembles that of the current ODP in order to better estimate the value of this approach to officer personnel planning.
-
EARTHQUAKE PERFORMANCE EVALUATION OF PVC PIPELINES WITH RESTRAINED JOINTS
Full-scale test results to evaluate the earthquake performance of 6-in. (150-mm) PVC pipelines with restrained bell-and-spigot joints under water pressure of at least 80 psi (550 kPa) are summarized for material properties, axial joint tension and compression, four-point bending, and axial pullout …
-
Fracture Characteristics of Asphalt Concrete in Mode I, Mode II, and Mixed-Mode
Three mixtures from the full-scale test sections discussed above were used to develop and validate a new Mode II test for asphalt concrete. No previous literature was found that attempted to capture Mode II fracture energy in asphalt concrete, so a test was developed from an extensive review of …
-
NUMERICAL, ANALYTICAL AND EXPERIMENTAL STUDY OF THE THERMAL BEHAVIOUR OF INNOVATIVE ENERGY GEOSTRUCTURES
… soil and open water. This study builds upon a full-scale EQW test installed in Delft, the Netherlands, which incorporated three distinct types of steel heat exchangers: (1) shallow loops and (2) add-on panels, both installed at a depth of 3 m, and (3) deep loops, positioned at a depth of 15 m. …
-
Spatial Variability and Terminal Density -Implications in Soil Behavior-
… an extensive field monitoring component. This full scale test lasts one year and includes four blasting events.
-
Impact of added insulation on the hygrothermal performance of leaky exterior wall assemblies
… The procedure involves the construction of a full-scale test hut exposed consecutively to climatic conditions representing winter and late spring, inside the environmental chamber. Two re-insulation strategies are studied, with three different air leakage patterns, and compared to an insulated …
-
In-situ mechanical behaviour of Huntly coal
… of Huntly coal are investigated. Laboratory tests on core specimens and small scale in-situ pressuremeter testing are used to determine elastic properties and failure criteria of the coal and coal measure rocks. The in-situ stress field that exists in the Waikato basin and in particular in …
-
The Design of Daylight Transporting Systems for Deep Space Illumination
… window opening on one side was constructed as a test cell. Inside, sensors were set up to allow light measurement at task level along the depth of the room. Light rays were deflected by the geometry of the ceiling cavity, through a number of internal reflections on the highly reflective film …
-
Laboratory and full-scale pavement sections testing for evaluating frost action in cold regions
A comprehensive laboratory testing plan was conducted as part of this project to select two frost-susceptible soils for use in constructing three full-scale test strips. A total of 16 soils were obtained from various suppliers in NJ and were evaluated to determine their frost-susceptibility. The …
-
DEVELOPMENT OF ELECTRICALLY CONDUCTIVE ASPHALT PAVEMENTS FOR DEICING APPLICATIONS IN COLD REGIONS
… to mixture with 30% graphite. Subsequently, full-scale test strips were constructed in New Jersey and Alaska using the ECA mixtures to further evaluate the deicing effectiveness and mechanical performance on a structural level. The deicing performance indicated that the ECA test strips could …
Page 1 of 6