Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 140 for “"full-scale tests"”.
-
Column-Supported Embankments: Full-Scale Tests and Design Recommendations
… test procedures are described. A total of 5 CSE tests were conducted with 2 ft diameter columns in a square array. The first test had a column center-to-center spacing of 10 ft and the remaining four tests had center-to-center spacings of 6 ft. The Adapted Terzaghi Method of determining the …
-
Bracing of steel bridges during construction; theory, full-scale tests and simulations
… include the derivation of analytical solutions, full-scale laboratory testing, and numerical modeling. The results of a part of the study showed that the load-carrying capacity of The Marcy Bridge that collapsed in 2002 could be improved by adding top flange plan bracing at 10-20% of its span …
-
Full Scale Tests on the Performance of Hybrid Timber Connections in Real Fires
Connections form an integral part of any building system. Concerns are raised when dealing with hybrid connections especially in fire. This is because different materials with varying ambient and thermal properties must perform together to ensure a stable structural system. This research seeks to …
-
Full Scale Tests on the Discharge Characteristics, Drainage Characteristics and Fire Suppression Performance of Portable Compressed Air Foam System
… conditions were determined. Discharge range tests and flow rate test indicated a linear progression with increasing pressure. Overall, all the tested foams met the requirements of the CAN/ULC-S508 standard. The drainage characteristics of foams, with and without thermal radiation, were …
-
Technological approaches to improve the engine efficiency and to reduce pollutant emissions of automotive diesel engines.
… incompatible were assessed through a set of full- scale tests on a real diesel engine in order to satisfy the new emissions limits. (1) The first strategy evaluated in this work to improve the engine efficiency was the reduction of the mechanical losses: through the incorporation of …
-
Lateral Torsional Buckling of Wood Beams
… program consists of conducting material tests to determine the longitudinal modulus of elasticity and rigidity modulus followed by a series of 18 full-scale tests. The buckling loads and mode shapes are documented. The numerical component of the study captures the orthotropic constitutive …
-
Concrete wall subjected to fragment impacts - Numerical analyses of perforation and scabbing
… were verified by results of already performed full-scale tests. The model was calibrated from information gained from a parameter study of the most important parameters such as tensile strength, softening energies, strain rate and shear strength. It was found out that by a calibration of the …
-
Analytical Model of Cold-formed Steel Framed Shear Wall with Steel Sheet and Wood-based Sheathing
… shear walls is capacity-based and developed from full-scale tests. The available design provisions provide nominal shear strength for only limited wall configurations. This research focused on the development of analytical models of cold-formed steel framed shear walls with steel sheet and …
-
Compartment Fire Toxicity: Measurements and Aspects of Modelling
… for faster generation of such data on bench scale apparatus. The models for overall toxicity assessment (for irritants and asphyxiants) were reviewed and the reported threshold limits for typical smoke toxicants, were collected, categorised and compared for increasing levels of harm. An …
-
Experimental Investigation of Lateral Torsional Buckling of Gerber Frames
… buckling resistance of Gerber frames based on full scale tests and finite element analyses. Three experiments were undertaken to obtain elastic buckling loads and the buckling modes were recorded. Shell finite element solutions were conducted to predict the elastic lateral buckling resistance …
-
Fire Performance of Hybrid Timber Connections
… a glulam beam and a steel column by conducting full scale tests and finite element modeling. The experimental part of this research consisted of a series of full-scale tests conducted in compliance with CAN/ULC-S101. Three different types of connections were investigated, Concealed shear tabs, …
-
Geosynthetic-reinforced soil retaining walls subjected to surcharge loads
… number of retaining structures have been successfully constructed using geosynthetic reinforcement layers. In many of these retaining structures, footings are located on the backfill and over the soil (e.g. footings on bridge abutments or roads located on top of the retaining structure). Despite …
-
Rutting Performance of Airport Hot-Mix Asphalt Characterized by Laboratory Performance Testing, Full-Scale Accelerated Pavement Testing, and Finite Element Modeling
… of results from four potential laboratory tests, (b) comparisons of laboratory tests results to full-scale accelerated pavement test results, and (c) analyses of results from finite element simulations. The laboratory study evaluated of the repeated load test, the static creep test, the …
-
Plastic interaction relations for hollow structural steel sections.
… an experimental program consisting of six full-scale tests on pipe sections under load combinations of shearing forces, bending moments, and twisting moments. The experimental results agree very well with the predicted failure loads based on recently developed interaction relations. The …
-
Alternative Dynamic Testing by Active Control
… for experimental validation of designs with full-scale tests (e.g. shake table and pseudo dynamic testing) can be extremely expensive and the facilities necessary are not available at many universities. This thesis proposes an Alternative Dynamic Test which uses a properly scaled model test …
-
The prediction of moment-rotation curves of extended endplate connections for use in semi-rigid analysis of steel frameworks
… for these analyses is by conducting expensive full-scale testing of connection subassemblies. There is a need for methods of prediction for all types of steel framework connections. In this study a method of predicting the behaviour of extended endplate connections has been presented. …
-
Uplift loaded standing seam roof systems
… standing seam roof system. Four sets of full-scale tests were conducted and their results were analyzed along with previous results (Anderson 1991). It was found that by normalizing the data, a reduction factor could be established for each test set configuration. This reduction factor …
-
Influência da temperatura e da sequência de empilhamento de camadas na resistência à pressão externa de dutos de compósitos
… is done safely. In this way, a series of small-scale characterization tests were conducted on typical composites for this application, and their results were used to calibrate some failure criteria from the literature. Then, these criteria were applied to numerical models representing pipes …
-
Behaviour of unstiffened column webs in bolted beam-to-column connections in building frames
… column web failure moments based on a series of full scale tests (flush and extend end plates) carried out at the University of Abertay Dundee.<br/>Buckling of the column web was observed in a large number of the bolted beam-to-column connections tested.<br/>Three dimensional finite element …